Image is for reference only, refer to product info for complete details.
The direct reading scales eliminate troublesome conversions. The scales are brushed aluminum, coated with epoxy and the graduations are on both sides of the indicating tube. Special integral flow guides stabilize the float throughout the range to keep it from hunting or wandering in the bore. The float is highly visible against a white background.
The direct reading scales eliminate troublesome conversions. The scales are brushed aluminum, coated with epoxy and the graduations are on both sides of the indicating tube. Special integral flow guides stabilize the float throughout the range to keep it from hunting or wandering in the bore. The float is highly visible against a white background.
Features
Switch Specifications | |
Switch Type | Each set point has 2 Form C relays (DPDT) |
Repeatability | ±1% of FS |
Electrical Rating | 10 A at 28 VDC 10 A at 120 240 VAC |
Electrical Connections | Screw terminals. Use 167°F (75°C) copper conductors only |
Power Requirements | 120 VAC, 50/60 Hz 240 VAC and 24 VAC power optional |
Mounting Orientation | Diaphragm in vertical position. Consult factory for other position orientations |
Set Point Adjustment | Adjustable knobs on face |
Agency Approvals | CE, CSA, UL |
Gauge Specifications | |
Service | Air and non-combustible, compatible gases |
Accuracy | ±2% of FS at 70°F (21.1°C) ±3% on -0 ±4% on -00 models |
Pressure Limits | -20" Hg to 25 psig (-0.677 to 1.72 bar) MP option; 35 psig (2.41 bar) HP option; 80 psig (5.52 bar) |
Temperature Limits | 20 to 120°F. (-6.67 to 48.9°C) -20 to 120°F (-28 to 48.9°C) with low temperature option |
Process Connections | ⅛ female NPT |
Dimensions | 4" (101.6 mm) dial face 5 x 8¼" (127 x 209.55 mm) |
Weight | 4 lb (1.81 kg) |
Switch Specifications | |
Switch Type | Each set point has 2 Form C relays (DPDT) |
Repeatability | ±1% of FS |
Electrical Rating | 10 A at 28 VDC 10 A at 120 240 VAC |
Electrical Connections | Screw terminals. Use 167°F (75°C) copper conductors only |
Power Requirements | 120 VAC, 50/60 Hz 240 VAC and 24 VAC power optional |
Mounting Orientation | Diaphragm in vertical position. Consult factory for other position orientations |
Set Point Adjustment | Adjustable knobs on face |
Agency Approvals | CE, CSA, UL |
Gauge Specifications | |
Service | Air and non-combustible, compatible gases |
Accuracy | ±2% of FS at 70°F (21.1°C) ±3% on -0 ±4% on -00 models |
Pressure Limits | -20" Hg to 25 psig (-0.677 to 1.72 bar) MP option; 35 psig (2.41 bar) HP option; 80 psig (5.52 bar) |
Temperature Limits | 20 to 120°F. (-6.67 to 48.9°C) -20 to 120°F (-28 to 48.9°C) with low temperature option |
Process Connections | ⅛ female NPT |
Dimensions | 4" (101.6 mm) dial face 5 x 8¼" (127 x 209.55 mm) |
Weight | 4 lb (1.81 kg) |