Bezel and front cover (with set point knobs and zero adjustment screw) removed to expose Photohelic® switch/gage set point mechanism. Cover is clear polycarbonate plastic. Gage pointer and light shutter are mounted on helix and balancing counterweight.

Bezel and front cover (with set point knobs and zero adjustment screw) removed to expose Photohelic® switch/gage set point mechanism. Cover is clear polycarbonate plastic. Gage pointer and light shutter are mounted on helix and balancing counterweight.

Sale Price $894.66 CAD
Regular Price $962.00 CAD
Availability 4 in Stock
Quantity

ISO Certified In-House Calibration Certificate for your Dwyer A3010 Photohelic Pressure Switch/Gauge (0-10"w.c.)

ISO Certified In-House Calibration Certificate for your Dwyer A3010 Photohelic Pressure Switch/Gauge (0-10"w.c.)

Dwyer A3010 Pressure switch/gage, range 0-10

The Dwyer A3010 Pressure Switch/Gauge has a range of 0-8" w.c.

Photohelic® Switch/Gauges function as versatile, highly repeatable pressure switches combined with a precise pressure gauge employing the time-proven Magnehelic® gauge design. The Photohelic® switch/gage measures and controls positive, negative or differential pressures of air and compatible gases. Standard models are rated to 25 psig (1.7 bar) with options to 35 (2.4) or 80 (5.5 bar) psig. Single pressure 36000S models measure to 6000 psig (413 bar) with a 9000 psig (620 bar) rating. Two phototransistor actuated, DPDT relays are included for low/high limit control. Easy to adjust set point indicators are controlled by knobs located on the gauge face. Individual set point deadband is one pointer width - less than 1% of full scale. Set points can be interlocked to provide variable deadband - ideal for control of fans, dampers, etc. Gauge reading is continuous and unaffected by switch operation, even during loss of electrical power. Choose from full scale pressure ranges from a low 0-.25" (0-6 mm) w.c. up to 30 psi (21 bar); single positive pressure to 6000 psig (413 bar).

Photohelic Sensing - How It Works
In typical applications, these Dwyer switch/gages control between high and low pressure set points. When pressure changes, reaching either set point pressure, the infrared light to the limiting phototransistor is cut off by the helix-driven light shutter. The resulting phototransistor signal is electronically amplified to actuate its DPDT slave relay and switching occurs. Dead band between make and break is 1% of full scale or less - just enough to assure positive, chatter-free operation.

Relay-Transformer Features
A plastic housing protects all electronic components. Solid-state and integrated circuit electronics are on glass-epoxy printed circuit boards and self-extinguishing terminal boards.

Dwyer A3010 Specifications

Switch Specifications
Switch Type Each set point has 2 Form C relays (DPDT)
Repeatability ±1% of FS
Electrical Rating 10 A at 28 VDC
10 A at 120
240 VAC
Electrical Connections Screw terminals. Use 167°F (75°C) copper conductors only
Power Requirements 120 VAC, 50/60 Hz
240 VAC and 24 VAC power optional
Mounting Orientation Diaphragm in vertical position. Consult factory for other position orientations
Set Point Adjustment Adjustable knobs on face
Agency Approvals CE, CSA, UL
Gauge Specifications
Service Air and non-combustible, compatible gases
Accuracy ±2% of FS at 70°F (21.1°C)
±3% on -0
±4% on -00 models
Pressure Limits -20" Hg to 25 psig (-0.677 to 1.72 bar)
MP option; 35 psig (2.41 bar)
HP option; 80 psig (5.52 bar)
Temperature Limits 20 to 120°F. (-6.67 to 48.9°C)
-20 to 120°F (-28 to 48.9°C) with low temperature option
Process Connections ⅛ female NPT
Dimensions 4" (101.6 mm) dial face
5 x 8¼" (127 x 209.55 mm)
Weight 4 lb (1.81 kg)
Click here for complete specifications on the Dwyer A3010

What's included with the Dwyer A3010

  • Dwyer A3010 Photohelic Pressure Switch/Gauge (0-10"w.c.)

Ask a question about Dwyer A3010 Photohelic Pressure Switch/Gauge (0-10"w.c.)

Customer Reviews for the Dwyer A3010

Dwyer A3010 Pressure switch/gage, range 0-10

The Dwyer A3010 Pressure Switch/Gauge has a range of 0-8" w.c.

Photohelic® Switch/Gauges function as versatile, highly repeatable pressure switches combined with a precise pressure gauge employing the time-proven Magnehelic® gauge design. The Photohelic® switch/gage measures and controls positive, negative or differential pressures of air and compatible gases. Standard models are rated to 25 psig (1.7 bar) with options to 35 (2.4) or 80 (5.5 bar) psig. Single pressure 36000S models measure to 6000 psig (413 bar) with a 9000 psig (620 bar) rating. Two phototransistor actuated, DPDT relays are included for low/high limit control. Easy to adjust set point indicators are controlled by knobs located on the gauge face. Individual set point deadband is one pointer width - less than 1% of full scale. Set points can be interlocked to provide variable deadband - ideal for control of fans, dampers, etc. Gauge reading is continuous and unaffected by switch operation, even during loss of electrical power. Choose from full scale pressure ranges from a low 0-.25" (0-6 mm) w.c. up to 30 psi (21 bar); single positive pressure to 6000 psig (413 bar).

Photohelic Sensing - How It Works
In typical applications, these Dwyer switch/gages control between high and low pressure set points. When pressure changes, reaching either set point pressure, the infrared light to the limiting phototransistor is cut off by the helix-driven light shutter. The resulting phototransistor signal is electronically amplified to actuate its DPDT slave relay and switching occurs. Dead band between make and break is 1% of full scale or less - just enough to assure positive, chatter-free operation.

Relay-Transformer Features
A plastic housing protects all electronic components. Solid-state and integrated circuit electronics are on glass-epoxy printed circuit boards and self-extinguishing terminal boards.

Dwyer A3010 Specifications

Switch Specifications
Switch Type Each set point has 2 Form C relays (DPDT)
Repeatability ±1% of FS
Electrical Rating 10 A at 28 VDC
10 A at 120
240 VAC
Electrical Connections Screw terminals. Use 167°F (75°C) copper conductors only
Power Requirements 120 VAC, 50/60 Hz
240 VAC and 24 VAC power optional
Mounting Orientation Diaphragm in vertical position. Consult factory for other position orientations
Set Point Adjustment Adjustable knobs on face
Agency Approvals CE, CSA, UL
Gauge Specifications
Service Air and non-combustible, compatible gases
Accuracy ±2% of FS at 70°F (21.1°C)
±3% on -0
±4% on -00 models
Pressure Limits -20" Hg to 25 psig (-0.677 to 1.72 bar)
MP option; 35 psig (2.41 bar)
HP option; 80 psig (5.52 bar)
Temperature Limits 20 to 120°F. (-6.67 to 48.9°C)
-20 to 120°F (-28 to 48.9°C) with low temperature option
Process Connections ⅛ female NPT
Dimensions 4" (101.6 mm) dial face
5 x 8¼" (127 x 209.55 mm)
Weight 4 lb (1.81 kg)