Onset HOBO T-VER-8053-800 Veris Kilowatt-Hour Transducer, 800 A, 3-ph

Model: T-VER-8053-800

Onset HOBO T-VER-8053-800 Veris Kilowatt-Hour Transducer, 800 A, 3-ph

Model: T-VER-8053-800

The Veris AC Kilowatt Transducer incorporates three split-core AC current sensors and three voltage leads and outputs a signal proportional to kilowatts of power (demand). Accepting an input primary voltage of 208 to 480VAC rms, this transducer requires S-UCC-M001 or S-UCC-M006 Pulse Input Adapter.

The Veris AC Kilowatt Transducer incorporates three split-core AC current sensors and three voltage leads and outputs a signal proportional to kilowatts of power (demand). Accepting an input primary voltage of 208 to 480VAC rms, this transducer requires S-UCC-M001 or S-UCC-M006 Pulse Input Adapter.

Your Price $1591.00 CAD
Availability 2 to 3 Weeks
Quantity

Onset HOBO T-VER-8053-800 Offers

Accepting an input primary voltage of 480 Volts AC rms, this transducer requires a Pulse Input Adapter. Because these sensors tie directly into the line, they should be used only by qualified personnel. NOTE: Not recommended for use with variable frequency drives.

Features

  • Split-core installation eliminates the need to remove conductors
  • Self-contained 0 to 800 AMP current transducer for large 3-phase AC loads
  • Accurate electronic pulse output

Onset HOBO T-VER-8053-800 Specifications

Frequency 50 to 60Hz
Accuracy ±1% (3-Phase Model Conforms to ANSI C12.1 Metering Standards)
CT Range 0 to 800 Amp
Circuit Connection 3 or 4-wire
Maximum Output Current 100mA at 24VAC/DC
Operating Temperature Range 0 to 60°C (32 to 140°F)
Operating Humidity Range 0 to 95% RH, Non-Condensing
Output Signal to HOBO Energy Logger Pulse (Normally Open Opto-FET)
Pulse Width 200 msec
Click here for complete specifications on the Onset HOBO T-VER-8053-800

What's included with the Onset HOBO T-VER-8053-800

  • Onset HOBO T-VER-8053-800 Veris Kilowatt-Hour Transducer, 800 A, 3-ph

Ask a question about Onset HOBO T-VER-8053-800 Veris Kilowatt-Hour Transducer, 800 A, 3-ph

Customer Reviews for the Onset HOBO T-VER-8053-800

Onset HOBO T-VER-8053-800 Offers

Accepting an input primary voltage of 480 Volts AC rms, this transducer requires a Pulse Input Adapter. Because these sensors tie directly into the line, they should be used only by qualified personnel. NOTE: Not recommended for use with variable frequency drives.

Features

  • Split-core installation eliminates the need to remove conductors
  • Self-contained 0 to 800 AMP current transducer for large 3-phase AC loads
  • Accurate electronic pulse output

Onset HOBO T-VER-8053-800 Specifications

Frequency 50 to 60Hz
Accuracy ±1% (3-Phase Model Conforms to ANSI C12.1 Metering Standards)
CT Range 0 to 800 Amp
Circuit Connection 3 or 4-wire
Maximum Output Current 100mA at 24VAC/DC
Operating Temperature Range 0 to 60°C (32 to 140°F)
Operating Humidity Range 0 to 95% RH, Non-Condensing
Output Signal to HOBO Energy Logger Pulse (Normally Open Opto-FET)
Pulse Width 200 msec
Click here for complete specifications on the Onset HOBO T-VER-8053-800

What's included with the Onset HOBO T-VER-8053-800

  • Onset HOBO T-VER-8053-800 Veris Kilowatt-Hour Transducer, 800 A, 3-ph

Ask a question about Onset HOBO T-VER-8053-800 Veris Kilowatt-Hour Transducer, 800 A, 3-ph

Customer Reviews for the Onset HOBO T-VER-8053-800

More Onset HOBO Products