Megger MPQ2000 Power Quality Analyzer Basic Sales Kit, 1000 V AC, 1500 V DC

Model: MPQ2000-BASIC

Megger MPQ2000 Power Quality Analyzer Basic Sales Kit, 1000 V AC, 1500 V DC

Model: MPQ2000-BASIC

Highly intuitive and advanced, this three-phase analyzer lets you view RMS data, waveforms, demand data, phase angles, harmonics, unbalance, and flicker in real-time. This kit comes with an analyzer, voltage leads, an SD card, a USB cable, an ethernet cable, universal power cords, fuse adapters, and a soft-sided carrying case.

Highly intuitive and advanced, this three-phase analyzer lets you view RMS data, waveforms, demand data, phase angles, harmonics, unbalance, and flicker in real-time. This kit comes with an analyzer, voltage leads, an SD card, a USB cable, an ethernet cable, universal power cords, fuse adapters, and a soft-sided carrying case.

Regular Price $12835.00 CAD
Availability 2 to 3 Weeks
Quantity

Megger MPQ2000-BASIC Offers

Ideal for testing power quality in any environment, this kit includes rugged and weatherproof hardware and the ability to power off Phase A or auxiliary power. Errors are minimized, making your testing more efficient with industry-leading software that enables you to analyze your results quickly and easily.

When data recording is needed, the record verification automatically identifies the current clamps, recognizes their range, and verifies that the unit is connected. In addition, this analyzer can record for extended periods because of its massive memory, utilizing an SD card which makes expanding the memory as easy as installing a new SD card. You can access the recorded data on the unit's color VGA display and transfer data to the high-power PQ Power Quality Analysis software via USB cable, USB stick, Ethernet, or the SD card.

The free software, which requires no license, optimizes this analyzer to locate the power quality phenomenon such as lighting issues, computer problems, tripping breakers, etc.

Features

  • EC61000-4-30 Class A compliance
  • Powered off of phase A voltage AC/dDC
  • 1000 V AC and 1500 V DC range
  • Real time scope and DVM
  • Connection verification
  • On-board data analysis
  • Powering off phase A makes the unit versatile, allowing its use in any location
  • IP54 weatherproof enclosure is designed for outdoor operation. The unit is robust enough to remain recording outdoors
  • Automated configuration in the PQ software for quick and easy setup
  • Easy intuitive menus allow for simple navigation and operation
  • Record verification ensures the unit is configured correctly and you get the data you need — no wasted recordings
  • Automatic CT recognition means never having the unit programmed for a wrong range
  • CTs are powered by the unit so there's no need for additional connections or batteries
  • Full-featured Class A compliant (all parameters)
  • On-board data analysis saves time by allowing an immediate examination of the data while still in the field
  • The expanded 1000 V AC range allows for more applications; no need for a second unit
  • 1000 DC measurement allows testing and analysis of renewable applications dismissing the need for additional equipment
  • Phase angle stability measurement lets you easily find tricky phasing problems caused by multiple erratic sources
  • CAT IV at 600 V ensures a safe unit for all applications
  • Multiple communication methods (USB, Ethernet, USB stick or SD card) allow flexible and convenient operation
  • Removable SD card allows for large recording capabilities and simple memory expansion
  • Included PC software: Data analysis, configuration wizard, analyze waveforms through 128th order

Applications

  • Compliance testing to any PQ standard
  • Power factor studies
  • Load studies and load balancing
  • Billing verification
  • Substation monitoring
  • Capacitor bank sizing
  • Transformer analysis and de-rating
  • Motor troubleshooting and inrush testing
  • Switchgear and component failure
  • Tripping breakers
  • Equipment tripping offline
  • Dimming/surging lighting
  • Lamp flicker analysis
  • Neutral overheating

Megger MPQ2000-BASIC Specifications

Input Power Phase A 90-600V 50/60 Hz or 105-600 V DC
Aux input power - 120/240 V, 50/60 Hz
Water-tight cord to operate off standard US, UK and EU plugs
Supports live connect/disconnect
Battery NiMH battery pack (field replaceable)
Discharge time: 8 hours
Recharge time: 3 hours
Data Storage External SD card (up to 32 GB)
Communication Ethernet communications: network communications. Wireless communications with off-the-shelf bridge. USB stick - transfer data file to USB. Transfer setup configurations to and from USB stick. Perform firmware upgrades using USB stick. SD card: automatically writes data to SD card; no manual transfer required. Transfer setup configurations to and from SD card. No tool needed to access the SD card.
Environmental Operating: -4°F to 122°F (-20°C to 50°C)
Storage: -22°F to 140°F (-30°C to 60°C)
Relative humidity: 0 to 95% non-condensing
Altitude 6561.68' (<2000 m): 1000V CAT III/600 V CAT IV
Altitude 6561.68 to 13,123.36' (2000 to 4000 m): 600 V CAT III/300 V CAT IV
Altitude 13,123.36 to 16,404.2' (4000 to 5000 m): 300 V CAT III/150 V CAT IV
Case Ruggedized enclosure IP54 when closed
Lockable by means of padlock
Display Backlit 4.53 x 3.35" (11.5 x 8.5 cm) color VGA
PQ Events Dips/sags: Triggers off of voltage and current IEC61000-4-30 compliant
Swells: Triggers off of voltage and current. IEC61000-4-30 compliant
Sub-cycle distortions: Triggers off of voltage and current IEC61000-4-30 compliant
Transient detection: 1 μsecond triggers off of first 3 voltage channels IEC61000-4-30 compliant
THD: Triggers off of voltage and current IEC61000-4-30 compliant
Rapid voltage change (RVC): Triggers off of first 3 voltage channels IEC61000-4-30 compliant
Phase shifts: Trigger event when a phase shift occurs between the voltage channels. Record date and time, duration and waveforms of all enabled channels. Phase shift user selectable down to 1°
Waveform capture of events: Capture waveforms on all enabled channels when an out of limits event occurs. Waveforms programmable with up to 9 pre-trigger cycles and 3600 post-trigger cycles
Timed waveform capture: Captures waveforms periodically on all enabled channels. Waveform capture interval programmable down to 1 cycle. Programmable number of cycles to be captured up to 200
cycles
Event triggered waveforms and timed triggered waveforms simultaneously
Mains signaling events: Two selectable frequencies and amplitudes
Selectable time interval. Measured per IEC61000-4-30
Captures waveforms on all enabled channels when a mains signaling event occurs. Waveform programmable with up to 9 pre-trigger cycles and 99 post-trigger cycles.
Event flagging: Measured per IEC61000-4-30
Motor Inrush Can record RMS, power, energy and PF every 1 cycle simultaneously continuously
Can capture up to 1 minute of raw waveform data on every motor start up on all channels simultaneously
Can monitor a motor for weeks of months continuously
Support both three-phase and single-phase motors
Real Time Data Scope mode:
View waveforms in scope mode
Freeze, zoom and pan
View vector scope
View ANSI unbalance
View IEC unbalance
View harmonic in real time
View inter-harmonics in real time
View RMS voltage and current in real time

DMM mode:
View IEC unbalance
View harmonic in real time
View RMS voltage and current in real time
View THD in real time
View active power in real time
View reactive power in real time
View apparent power in real time
View DPF in real time
View TPF in real time
View flicker in real time
Compliance IEC61000-4-7
IEC61000-4-30 Ed. 3 (Class A)
IEC61000-4-15
IEC61000-4-27
IEC61010-1
RoHS2 Directive 2011/65/EU
IEC6132
IEC60529
MIL-STD-810 G
IEEE 1453
IEEE 1459
CAN/CSA-C22 No. 1010.1-92
Sampling Resolution: 16-bit analog to digital converter on 8 channels
Maximum speed: 1 MHz
Maximum RMS: 17,664 per channel
PLL synchronization: 42.5 to 69 Hz
Real Time Clock Accuracy: ±20 ppm
Voltage AC voltage range: 0 to 1000 V AC RMS
DC voltage range: ±1500 V DC
AC voltage accuracy: 0.1% per IEC61000-4-30
DC voltage accuracy: ±0.2% of full scale ±2 V DC
Voltage ratios: Adjustable voltage ratios for measuring secondaries (0.0001 through 9999)
Resolution: 16 bit
Crest factor: 1.5
Maximum pk voltage: 1628 V/2500 V
Impedance: 20.01 MΩ to gnd nominal
Voltage lead set: 4 voltage leads, 6' (2 m) in length, safety banana leads, removable alligator clips, set of color bands for customizing color codes, safety green/yellow ground lead
Current Channels 5 current channels
Range: 0 to 6000 A (CT dependent)
Ratios: Adjustable current ratios for measuring secondaries (000.1 through 9999)
AC accuracy: ±0.5% of reading ±0.05% of full scale
DC accuracy: ±1.0% of full scale
Resolution: 16 bit
Crest factor: 4.0
Power and Energy Active power (KW): Per IEEE1459
Reactive power (KVAR): Per IEEE1459
Apparent power (KVA): Per IEEE1459
Energy parameters (KWH, KVARH, KVAH): Per IEEE1459
Displacement power factor range: -1 to 1
Displacement power factor accuracy: ±0.02 + CT error
True power factor range: 0 to 1
True power factor accuracy: ±0.02 + CT error
Power configurations: 11
Aggregation window: 1 cycle to 1 hour - fixed and sliding windows
Unbalance: ANSI and IEC methodology per IEC61000-4-27
Total harmonic distortion (THD): Per IEC61000-4-30 & IEC 61000-4-7
Distortion 200ms, 3 seconds, 10 minutes windows
Vthd 0 to 100%, ±5% for V≥1% Vnom,
Ithd ±5% reading at ≥3% Inom, ±0.15% full scale at <3% Inom
Harmonics: 0 through 50th continuous
Inter-harmonics: 0 through 50th continuous
Total demand distortion (TDD): Per IEEE519
Frequency: Per IEC61000-4-30
Flicker: Per IEC61000-4-15
Pst: 10 minutes: 0.2-10, ±0.05 at Pst=1 (50/60 Hz only)
Plt: 2 hours: 0.2-10, ±0.05 at Pst=1 (50/60 Hz only)
Functions Auto identify CT and CT range setting
Configuration verification - Display if unit is connected incorrectly
On board analysis - Perform data analysis on unit. Compare recorded values against customizable templates
Waveform analysis through the 128th order
Clock hour orientation - Time sync recording to nearest interval
Scheduled run - Select start and stop time of recording. Instrument then automatically begins recording
On board configuration - Ability to configure recording parameters from front panel of instrument
Auto setup - Ability to have instrument automatically configure itself
On board naming of data and setup files -Ability to name data and setup files from the front panel of the instrument
Supported languages: English, Spanish, French, German and Czech
On board instrument preference settings:
Selectable traces colors
Selectable short cut buttons
Selectable time out period
Chart grid ON/OFF
Measurement Parameters RMS voltage
RMS current
Sags/dips/swells
Transients (1 msecond) (±2697 V)
Sub-cycle events 64 msecond (notching, noise)
Rapid voltage change
Phase angle stability
IEC unbalance
ANSII unbalance
Power (KW, KVAR, KVA, DPF and TPF)
Energy (KWH, KVARH and KVAH)
Power factor 1 to 0 to -1
Phase angle
THD
TDD
Harmonics
Inter-harmonics
Power harmonics
Harmonic direction
Flicker
Waveform capture
Frequency
Software Windows compliant (XP, Win 7, 8, 10)
Click here for complete specifications on the Megger MPQ2000-BASIC

What's included with the Megger MPQ2000-BASIC

  • Analyzer
  • 4 x Voltage Leads
  • SD Card
  • USB Cable
  • Ethernet Cable
  • Universal Power Cords
  • Plus Fuse Adapters
  • Soft-Sided Carrying Case

Click on a category to view a selection of compatible accessories with the Megger MPQ2000 Power Quality Analyzer Basic Sales Kit, 1000 V AC, 1500 V DC.

Megger CP-20CE-ID Split Core CT, 20 A CP-20CE-ID
For use with the MPQ1000 Power Quality Analyzers.




Megger MCCV6000-18 Flexible Rope Current Clamp, 4-Range, Self-Identifying, 6000A AC, 18 cm ID MCCV6000-18
Four range self-identifying flexible current clamp. 18 cm inner diameter (ID). Automatically identifies the range to which the CT is set. Supported ranges are: 0 to 60A, 0 to 600A, 0 to 3000A and 0 to 6000A.




Megger MCCV6000-27 Flexible Rope Current Clamp, 4-Range, Self-Identifying, 6000A AC, 27 cm ID MCCV6000-27
Four range self-identifying flexible current clamp. 27 cm inner diameter (ID). Automatically identifies the range to which the CT is set. Supported ranges are: 0 to 60A, 0 to 600A, 0 to 3000A and 0 to 6000A.




Megger CP-5CE-ID Split Core Current Clamp, 5A, 6ft. CP-5CE-ID
Split core current clamp 5A range self identifying CT. For use with MPQ power quality analyzers.




Megger CP-600DC-ID Split Core CT, 600 A CP-600DC-ID
For use with the MPQ1000 Power Quality Analyzers.




Ask a question about Megger MPQ2000 Power Quality Analyzer Basic Sales Kit, 1000 V AC, 1500 V DC

Customer Reviews for the Megger MPQ2000-BASIC

Megger MPQ2000-BASIC Offers

Ideal for testing power quality in any environment, this kit includes rugged and weatherproof hardware and the ability to power off Phase A or auxiliary power. Errors are minimized, making your testing more efficient with industry-leading software that enables you to analyze your results quickly and easily.

When data recording is needed, the record verification automatically identifies the current clamps, recognizes their range, and verifies that the unit is connected. In addition, this analyzer can record for extended periods because of its massive memory, utilizing an SD card which makes expanding the memory as easy as installing a new SD card. You can access the recorded data on the unit's color VGA display and transfer data to the high-power PQ Power Quality Analysis software via USB cable, USB stick, Ethernet, or the SD card.

The free software, which requires no license, optimizes this analyzer to locate the power quality phenomenon such as lighting issues, computer problems, tripping breakers, etc.

Features

  • EC61000-4-30 Class A compliance
  • Powered off of phase A voltage AC/dDC
  • 1000 V AC and 1500 V DC range
  • Real time scope and DVM
  • Connection verification
  • On-board data analysis
  • Powering off phase A makes the unit versatile, allowing its use in any location
  • IP54 weatherproof enclosure is designed for outdoor operation. The unit is robust enough to remain recording outdoors
  • Automated configuration in the PQ software for quick and easy setup
  • Easy intuitive menus allow for simple navigation and operation
  • Record verification ensures the unit is configured correctly and you get the data you need — no wasted recordings
  • Automatic CT recognition means never having the unit programmed for a wrong range
  • CTs are powered by the unit so there's no need for additional connections or batteries
  • Full-featured Class A compliant (all parameters)
  • On-board data analysis saves time by allowing an immediate examination of the data while still in the field
  • The expanded 1000 V AC range allows for more applications; no need for a second unit
  • 1000 DC measurement allows testing and analysis of renewable applications dismissing the need for additional equipment
  • Phase angle stability measurement lets you easily find tricky phasing problems caused by multiple erratic sources
  • CAT IV at 600 V ensures a safe unit for all applications
  • Multiple communication methods (USB, Ethernet, USB stick or SD card) allow flexible and convenient operation
  • Removable SD card allows for large recording capabilities and simple memory expansion
  • Included PC software: Data analysis, configuration wizard, analyze waveforms through 128th order

Applications

  • Compliance testing to any PQ standard
  • Power factor studies
  • Load studies and load balancing
  • Billing verification
  • Substation monitoring
  • Capacitor bank sizing
  • Transformer analysis and de-rating
  • Motor troubleshooting and inrush testing
  • Switchgear and component failure
  • Tripping breakers
  • Equipment tripping offline
  • Dimming/surging lighting
  • Lamp flicker analysis
  • Neutral overheating

Megger MPQ2000-BASIC Specifications

Input Power Phase A 90-600V 50/60 Hz or 105-600 V DC
Aux input power - 120/240 V, 50/60 Hz
Water-tight cord to operate off standard US, UK and EU plugs
Supports live connect/disconnect
Battery NiMH battery pack (field replaceable)
Discharge time: 8 hours
Recharge time: 3 hours
Data Storage External SD card (up to 32 GB)
Communication Ethernet communications: network communications. Wireless communications with off-the-shelf bridge. USB stick - transfer data file to USB. Transfer setup configurations to and from USB stick. Perform firmware upgrades using USB stick. SD card: automatically writes data to SD card; no manual transfer required. Transfer setup configurations to and from SD card. No tool needed to access the SD card.
Environmental Operating: -4°F to 122°F (-20°C to 50°C)
Storage: -22°F to 140°F (-30°C to 60°C)
Relative humidity: 0 to 95% non-condensing
Altitude 6561.68' (<2000 m): 1000V CAT III/600 V CAT IV
Altitude 6561.68 to 13,123.36' (2000 to 4000 m): 600 V CAT III/300 V CAT IV
Altitude 13,123.36 to 16,404.2' (4000 to 5000 m): 300 V CAT III/150 V CAT IV
Case Ruggedized enclosure IP54 when closed
Lockable by means of padlock
Display Backlit 4.53 x 3.35" (11.5 x 8.5 cm) color VGA
PQ Events Dips/sags: Triggers off of voltage and current IEC61000-4-30 compliant
Swells: Triggers off of voltage and current. IEC61000-4-30 compliant
Sub-cycle distortions: Triggers off of voltage and current IEC61000-4-30 compliant
Transient detection: 1 μsecond triggers off of first 3 voltage channels IEC61000-4-30 compliant
THD: Triggers off of voltage and current IEC61000-4-30 compliant
Rapid voltage change (RVC): Triggers off of first 3 voltage channels IEC61000-4-30 compliant
Phase shifts: Trigger event when a phase shift occurs between the voltage channels. Record date and time, duration and waveforms of all enabled channels. Phase shift user selectable down to 1°
Waveform capture of events: Capture waveforms on all enabled channels when an out of limits event occurs. Waveforms programmable with up to 9 pre-trigger cycles and 3600 post-trigger cycles
Timed waveform capture: Captures waveforms periodically on all enabled channels. Waveform capture interval programmable down to 1 cycle. Programmable number of cycles to be captured up to 200
cycles
Event triggered waveforms and timed triggered waveforms simultaneously
Mains signaling events: Two selectable frequencies and amplitudes
Selectable time interval. Measured per IEC61000-4-30
Captures waveforms on all enabled channels when a mains signaling event occurs. Waveform programmable with up to 9 pre-trigger cycles and 99 post-trigger cycles.
Event flagging: Measured per IEC61000-4-30
Motor Inrush Can record RMS, power, energy and PF every 1 cycle simultaneously continuously
Can capture up to 1 minute of raw waveform data on every motor start up on all channels simultaneously
Can monitor a motor for weeks of months continuously
Support both three-phase and single-phase motors
Real Time Data Scope mode:
View waveforms in scope mode
Freeze, zoom and pan
View vector scope
View ANSI unbalance
View IEC unbalance
View harmonic in real time
View inter-harmonics in real time
View RMS voltage and current in real time

DMM mode:
View IEC unbalance
View harmonic in real time
View RMS voltage and current in real time
View THD in real time
View active power in real time
View reactive power in real time
View apparent power in real time
View DPF in real time
View TPF in real time
View flicker in real time
Compliance IEC61000-4-7
IEC61000-4-30 Ed. 3 (Class A)
IEC61000-4-15
IEC61000-4-27
IEC61010-1
RoHS2 Directive 2011/65/EU
IEC6132
IEC60529
MIL-STD-810 G
IEEE 1453
IEEE 1459
CAN/CSA-C22 No. 1010.1-92
Sampling Resolution: 16-bit analog to digital converter on 8 channels
Maximum speed: 1 MHz
Maximum RMS: 17,664 per channel
PLL synchronization: 42.5 to 69 Hz
Real Time Clock Accuracy: ±20 ppm
Voltage AC voltage range: 0 to 1000 V AC RMS
DC voltage range: ±1500 V DC
AC voltage accuracy: 0.1% per IEC61000-4-30
DC voltage accuracy: ±0.2% of full scale ±2 V DC
Voltage ratios: Adjustable voltage ratios for measuring secondaries (0.0001 through 9999)
Resolution: 16 bit
Crest factor: 1.5
Maximum pk voltage: 1628 V/2500 V
Impedance: 20.01 MΩ to gnd nominal
Voltage lead set: 4 voltage leads, 6' (2 m) in length, safety banana leads, removable alligator clips, set of color bands for customizing color codes, safety green/yellow ground lead
Current Channels 5 current channels
Range: 0 to 6000 A (CT dependent)
Ratios: Adjustable current ratios for measuring secondaries (000.1 through 9999)
AC accuracy: ±0.5% of reading ±0.05% of full scale
DC accuracy: ±1.0% of full scale
Resolution: 16 bit
Crest factor: 4.0
Power and Energy Active power (KW): Per IEEE1459
Reactive power (KVAR): Per IEEE1459
Apparent power (KVA): Per IEEE1459
Energy parameters (KWH, KVARH, KVAH): Per IEEE1459
Displacement power factor range: -1 to 1
Displacement power factor accuracy: ±0.02 + CT error
True power factor range: 0 to 1
True power factor accuracy: ±0.02 + CT error
Power configurations: 11
Aggregation window: 1 cycle to 1 hour - fixed and sliding windows
Unbalance: ANSI and IEC methodology per IEC61000-4-27
Total harmonic distortion (THD): Per IEC61000-4-30 & IEC 61000-4-7
Distortion 200ms, 3 seconds, 10 minutes windows
Vthd 0 to 100%, ±5% for V≥1% Vnom,
Ithd ±5% reading at ≥3% Inom, ±0.15% full scale at <3% Inom
Harmonics: 0 through 50th continuous
Inter-harmonics: 0 through 50th continuous
Total demand distortion (TDD): Per IEEE519
Frequency: Per IEC61000-4-30
Flicker: Per IEC61000-4-15
Pst: 10 minutes: 0.2-10, ±0.05 at Pst=1 (50/60 Hz only)
Plt: 2 hours: 0.2-10, ±0.05 at Pst=1 (50/60 Hz only)
Functions Auto identify CT and CT range setting
Configuration verification - Display if unit is connected incorrectly
On board analysis - Perform data analysis on unit. Compare recorded values against customizable templates
Waveform analysis through the 128th order
Clock hour orientation - Time sync recording to nearest interval
Scheduled run - Select start and stop time of recording. Instrument then automatically begins recording
On board configuration - Ability to configure recording parameters from front panel of instrument
Auto setup - Ability to have instrument automatically configure itself
On board naming of data and setup files -Ability to name data and setup files from the front panel of the instrument
Supported languages: English, Spanish, French, German and Czech
On board instrument preference settings:
Selectable traces colors
Selectable short cut buttons
Selectable time out period
Chart grid ON/OFF
Measurement Parameters RMS voltage
RMS current
Sags/dips/swells
Transients (1 msecond) (±2697 V)
Sub-cycle events 64 msecond (notching, noise)
Rapid voltage change
Phase angle stability
IEC unbalance
ANSII unbalance
Power (KW, KVAR, KVA, DPF and TPF)
Energy (KWH, KVARH and KVAH)
Power factor 1 to 0 to -1
Phase angle
THD
TDD
Harmonics
Inter-harmonics
Power harmonics
Harmonic direction
Flicker
Waveform capture
Frequency
Software Windows compliant (XP, Win 7, 8, 10)
Click here for complete specifications on the Megger MPQ2000-BASIC

What's included with the Megger MPQ2000-BASIC

  • Analyzer
  • 4 x Voltage Leads
  • SD Card
  • USB Cable
  • Ethernet Cable
  • Universal Power Cords
  • Plus Fuse Adapters
  • Soft-Sided Carrying Case

Click on a category to view a selection of compatible accessories with the Megger MPQ2000 Power Quality Analyzer Basic Sales Kit, 1000 V AC, 1500 V DC.

Megger CP-20CE-ID Split Core CT, 20 A CP-20CE-ID
For use with the MPQ1000 Power Quality Analyzers.




Megger MCCV6000-18 Flexible Rope Current Clamp, 4-Range, Self-Identifying, 6000A AC, 18 cm ID MCCV6000-18
Four range self-identifying flexible current clamp. 18 cm inner diameter (ID). Automatically identifies the range to which the CT is set. Supported ranges are: 0 to 60A, 0 to 600A, 0 to 3000A and 0 to 6000A.




Megger MCCV6000-27 Flexible Rope Current Clamp, 4-Range, Self-Identifying, 6000A AC, 27 cm ID MCCV6000-27
Four range self-identifying flexible current clamp. 27 cm inner diameter (ID). Automatically identifies the range to which the CT is set. Supported ranges are: 0 to 60A, 0 to 600A, 0 to 3000A and 0 to 6000A.




Megger CP-5CE-ID Split Core Current Clamp, 5A, 6ft. CP-5CE-ID
Split core current clamp 5A range self identifying CT. For use with MPQ power quality analyzers.




Megger CP-600DC-ID Split Core CT, 600 A CP-600DC-ID
For use with the MPQ1000 Power Quality Analyzers.




Ask a question about Megger MPQ2000 Power Quality Analyzer Basic Sales Kit, 1000 V AC, 1500 V DC

Customer Reviews for the Megger MPQ2000-BASIC

More Megger Products