Instek GLC-9000 Leakage Current Tester

Model: GLC-9000

Instek GLC-9000 Leakage Current Tester

Model: GLC-9000

The GLC-9000, leakage current tester, is used to perform leakage current (or called touch current) tests on medical electrical (IEC 60601-1) and general purpose electric & electronic (IEC 60990) equipment.

The GLC-9000, leakage current tester, is used to perform leakage current (or called touch current) tests on medical electrical (IEC 60601-1) and general purpose electric & electronic (IEC 60990) equipment.

Sale Price $4953.17 CAD
Regular Price $5213.86 CAD
Availability 3 Days
Quantity

GW Instek GLC-9000 Offers

The Instek GLC-9000 Leakage Current Tester is suitable for leakage current measurement of medical or general electrical equipment.

The GLC-9000, leakage current tester, is used to perform leakage current tests on medical electrical and general purpose electric and electronic equipment. This tester engages with nine measurement networks to privde the simulation of human body whilst the EUT is taking a leakage current testing, in compliance with the specific standards or regulations such as IEC, UL, JIS, etc.

In order to provide a simple operation environment, the GLC-9000 equips large TFT LCD touch panel to configure system as well as to present the measurement settings information and result simultaneously. Besides, there are 50 preset testing conditions, which conform to IEC60990 and other standards, for general electric equipment can be recalled to reduce the setting time. In addition, 30 sets empty memory are available for user defined.

Features

  • Touch Panel with Color LCD Display
  • 9 Different Measurement Network to Simulate the Resistance of Human Body
  • 50 Sets Preset Test Conditions Conform to the IEC60990; 30 Sets Memories for Customer Defined
  • 8 Different Types of Leakage Current for General Electrical & Medical Equipment
  • Meter Function with SELV/CONV Function
  • Upper and Lower Limitations for PASS/FAIL judgement
  • Various Leakage Current Measuring Mode: DC/AC/AC+DC/AC Peak
  • Various Standard Interfaces: RS-232/GPIB/USB Host & Device/EXT/I/O

GW Instek GLC-9000 Specifications

DC
Ranges 50uA
500uA
5mA
25mA
Resolution 0.01uA
0.1uA
1uA
10uA
Accuracy ±1.0% fs/±(0.2% rdg+3dgt)
AC/AC+DC
Ranges 50uA
500uA
5mA
25mA
Resolution 0.01uA
0.1uA
1uA
10uA
Accuracy ±2.0% fs/±(2.0% rdg+6dgt) -- 10Hz<f≦100kHz
±2.0% fs/±(2.0% rdg+10dgt) -- 100kHz<f≦1MHz
General Specifications
Display 320 x 240 Color TFT LCD
Operation Touch Panel
Measurement Device 9 Kinds
Dimensions 330 x 150 x 350 mm
Weight Approx. 5kg
Click here for complete specifications on the GW Instek GLC-9000

What's included with the GW Instek GLC-9000

  • Leakage Current Tester
  • User Manual
  • 2 x Power Cord
  • 2 x Test Lead
  • 4 x Alligator Clips (2 x Red, 2 x Black)
  • Foil Probe

Ask a question about Instek GLC-9000 Leakage Current Tester

Customer Reviews for the GW Instek GLC-9000

GW Instek GLC-9000 Offers

The Instek GLC-9000 Leakage Current Tester is suitable for leakage current measurement of medical or general electrical equipment.

The GLC-9000, leakage current tester, is used to perform leakage current tests on medical electrical and general purpose electric and electronic equipment. This tester engages with nine measurement networks to privde the simulation of human body whilst the EUT is taking a leakage current testing, in compliance with the specific standards or regulations such as IEC, UL, JIS, etc.

In order to provide a simple operation environment, the GLC-9000 equips large TFT LCD touch panel to configure system as well as to present the measurement settings information and result simultaneously. Besides, there are 50 preset testing conditions, which conform to IEC60990 and other standards, for general electric equipment can be recalled to reduce the setting time. In addition, 30 sets empty memory are available for user defined.

Features

  • Touch Panel with Color LCD Display
  • 9 Different Measurement Network to Simulate the Resistance of Human Body
  • 50 Sets Preset Test Conditions Conform to the IEC60990; 30 Sets Memories for Customer Defined
  • 8 Different Types of Leakage Current for General Electrical & Medical Equipment
  • Meter Function with SELV/CONV Function
  • Upper and Lower Limitations for PASS/FAIL judgement
  • Various Leakage Current Measuring Mode: DC/AC/AC+DC/AC Peak
  • Various Standard Interfaces: RS-232/GPIB/USB Host & Device/EXT/I/O

GW Instek GLC-9000 Specifications

DC
Ranges 50uA
500uA
5mA
25mA
Resolution 0.01uA
0.1uA
1uA
10uA
Accuracy ±1.0% fs/±(0.2% rdg+3dgt)
AC/AC+DC
Ranges 50uA
500uA
5mA
25mA
Resolution 0.01uA
0.1uA
1uA
10uA
Accuracy ±2.0% fs/±(2.0% rdg+6dgt) -- 10Hz<f≦100kHz
±2.0% fs/±(2.0% rdg+10dgt) -- 100kHz<f≦1MHz
General Specifications
Display 320 x 240 Color TFT LCD
Operation Touch Panel
Measurement Device 9 Kinds
Dimensions 330 x 150 x 350 mm
Weight Approx. 5kg
Click here for complete specifications on the GW Instek GLC-9000

What's included with the GW Instek GLC-9000

  • Leakage Current Tester
  • User Manual
  • 2 x Power Cord
  • 2 x Test Lead
  • 4 x Alligator Clips (2 x Red, 2 x Black)
  • Foil Probe

Ask a question about Instek GLC-9000 Leakage Current Tester