Offering fast measurements, this kit features a portable photometer with a superior optical system. Waterproof, the meter utilizes a reference detector as well as narrowband interference. Kit comes fully equipped with CAL check standards, cuvettes, plastic caps, plastic inserts, scissors, a cleaning cloth, and a carrying case.
Offering fast measurements, this kit features a portable photometer with a superior optical system. Waterproof, the meter utilizes a reference detector as well as narrowband interference. Kit comes fully equipped with CAL check standards, cuvettes, plastic caps, plastic inserts, scissors, a cleaning cloth, and a carrying case.
Key Features
The internal reference system of the photometer compensates for any drifts due to power fluctuations or ambient temperature changes. With a stable source of light the readings are fast and stable between your blank (zero) measurement and sample measurement.
LED light sources offer superior performance compared to tungsten lamps. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce little heat, which could otherwise affect electronic stability.
Improved optical filters ensure greater wavelength accuracy and allow a brighter, stronger signal to be received. The end result is higher measurement stability and less wavelength error.
A focusing lens collects all of the light that exits the cuvette, eliminating errors from imperfections and scratches that may be present in the glass. The use of the convex lens reduces the need for indexing cuvettes.
The CAL Check feature allows for performance verification and calibration of the meter using NIST traceable standards. The CAL Check standard vials are developed to simulate a specific absorbance value at each wavelength to verify the accuracy of subsequent readings.
Waiting the proper reaction time is of key importance when performing colorimetric measurements. The countdown timer displays the time remaining until a measurement will be taken, ensuring consistent results between sample measurements and users.
The sample cell of the meter fits a round, glass cuvette with a 0.98" (25 mm) path length. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.
The meter is designed with a backlit, graphic LCD. With virtual keys, a battery status indicator, and error messages. Users will find the meter interface intuitive and easy to read. A dedicated help key provides information relating to the current meter operation, and can be used at any stage in the setup or measurement process to show contextual help.
The meter uses three common AA batteries that allow for about 800 measurements to be taken. The auto-off feature automatically shuts off the meter after 15 minutes of inactivity in order conserve battery life.
Free Chlorine | Range: 0.00 to 5.00 mg/L (as Cl2) Resolution: 0.01 mg/L Accuracy: ±0.03 mg/L ±3% of reading |
Total Chlorine | Range UHR: 0.00 to 500 mg/L (as Cl2) Resolution: 1 mg/L Accuracy: ±0.03 mg/L ±3% of reading |
Chlorine Method | Adaptation of the standard methods for examination of wastewater, 20th edition 4500-Cl |
Photometer/Colorimeter Light | Source: Light emitting diode Detector: Silicon photocell with narrow band interference filter at 420 nm |
Bandpass Filter | Bandwidth: 8 nm Wavelength accuracy: ±1.0 nm |
Cuvette Type | Round, 0.97" (24.6 mm) diameter (0.96" [22 mm] inside) |
GLP | Date, time of last calibration |
Display | 128 x 64 pixel B/W LCD with backlight |
Logging | Type: Automatic logging Memory: 50 measurements |
Battery Type/Life | 3 x 1.5 V AA battery >800 measurements (without backlight) |
Automatic Shut-Off | After 15 minutes of inactivity (30 minutes before a READ measurement) |
Environment | 32 to 122°F (0 to 50°C); relative humidity: 100% (IP 67, floating case) |
Dimensions | 5.61 x 4.03 x 2" (142.5 x 102.5 x 50.5 mm) |
Weight | 13.4 oz (380 g) with batteries |
Click on a category to view a selection of compatible accessories with the Hanna HI 97771C Free Chlorine and Total Chlorine UHR Portable Photometer Kit.
Free Chlorine | Range: 0.00 to 5.00 mg/L (as Cl2) Resolution: 0.01 mg/L Accuracy: ±0.03 mg/L ±3% of reading |
Total Chlorine | Range UHR: 0.00 to 500 mg/L (as Cl2) Resolution: 1 mg/L Accuracy: ±0.03 mg/L ±3% of reading |
Chlorine Method | Adaptation of the standard methods for examination of wastewater, 20th edition 4500-Cl |
Photometer/Colorimeter Light | Source: Light emitting diode Detector: Silicon photocell with narrow band interference filter at 420 nm |
Bandpass Filter | Bandwidth: 8 nm Wavelength accuracy: ±1.0 nm |
Cuvette Type | Round, 0.97" (24.6 mm) diameter (0.96" [22 mm] inside) |
GLP | Date, time of last calibration |
Display | 128 x 64 pixel B/W LCD with backlight |
Logging | Type: Automatic logging Memory: 50 measurements |
Battery Type/Life | 3 x 1.5 V AA battery >800 measurements (without backlight) |
Automatic Shut-Off | After 15 minutes of inactivity (30 minutes before a READ measurement) |
Environment | 32 to 122°F (0 to 50°C); relative humidity: 100% (IP 67, floating case) |
Dimensions | 5.61 x 4.03 x 2" (142.5 x 102.5 x 50.5 mm) |
Weight | 13.4 oz (380 g) with batteries |
Click on a category to view a selection of compatible accessories with the Hanna HI 97771C Free Chlorine and Total Chlorine UHR Portable Photometer Kit.