Gas Clip MGC-S-DOCK MGC Simple Dock Station

Model: MGC-S-DOCK

Gas Clip MGC-S-DOCK MGC Simple Dock Station

Model: MGC-S-DOCK

Accurately test up to four units at the same time, all data is simultaneously logged. The portable unit is protected with a durable case and the integrated USB memory can record all the data from the monitors while reducing testing time and gas usage.

Accurately test up to four units at the same time, all data is simultaneously logged. The portable unit is protected with a durable case and the integrated USB memory can record all the data from the monitors while reducing testing time and gas usage.

Sale Price $3089.21 CAD
Regular Price $3269.00 CAD
Availability 1 in Stock
Quantity

Gas Clip MGC-S-DOCK Offers

Features

  • Test 4 units at one time, up to 12 instruments in a minute
  • Easy 1 button operation
  • Robust rechargeable internal battery, up to 1500 tests before recharging
  • Internal gas cylinder regulator and pressure gauge
  • USB flash memory for bump test and event log storage
  • Optional unit configuration and firmware updates via GCT Manager Software
  • Rugged case or Wall Mount Dock case
  • No computer required to operate

Unit Configuration/Firmware Updates
In order to keep your fleet of gas detectors compliant with specific settings, we allow for the MGC Pump Dock to program each unit during either bump testing or calibration. The programmable fields are as follows: User ID, Calibration Interval, Bump Interval, Self-Test Interval, Low Alarm, High Alarm, Show Sensor Readings, Hide Bump Due LED and Hide Clock. For example, if your company or facility requires each detector on site to have specific alarm set points and a bump test interval, instead of programming each unit individually, the instruments can be group programmed while simultaneously bump testing (4 units at a time per MGC Pump Dock) using our GCT Manager software. As firmware updates become available, we can program each MGC Pump Dock to update units during bump testing and calibration. Facility safety standard compliance for single gas detectors is now easily achievable.

Event Data and Record Storage
In addition to performing tests, unit configurations and firmware updates, the MGC Pump Dock also stores important information about both the docking station and units tested. All tests performed on the docking station can be accessed from either the USB directly or using the GCT Manager software. Each bump test and calibration event is recorded and logged by date, time and serial number. Along with the test records, the individual event logs from each unit are saved. At the time of the test, the detector transmits its' event log to the memory. By default, the station will save the previous 10 event logs.

What's included with the Gas Clip MGC-S-DOCK

  • Gas Clip MGC-S-DOCK MGC Simple Dock Station

Ask a question about Gas Clip MGC-S-DOCK MGC Simple Dock Station

Customer Reviews for the Gas Clip MGC-S-DOCK

Gas Clip MGC-S-DOCK Offers

Features

  • Test 4 units at one time, up to 12 instruments in a minute
  • Easy 1 button operation
  • Robust rechargeable internal battery, up to 1500 tests before recharging
  • Internal gas cylinder regulator and pressure gauge
  • USB flash memory for bump test and event log storage
  • Optional unit configuration and firmware updates via GCT Manager Software
  • Rugged case or Wall Mount Dock case
  • No computer required to operate

Unit Configuration/Firmware Updates
In order to keep your fleet of gas detectors compliant with specific settings, we allow for the MGC Pump Dock to program each unit during either bump testing or calibration. The programmable fields are as follows: User ID, Calibration Interval, Bump Interval, Self-Test Interval, Low Alarm, High Alarm, Show Sensor Readings, Hide Bump Due LED and Hide Clock. For example, if your company or facility requires each detector on site to have specific alarm set points and a bump test interval, instead of programming each unit individually, the instruments can be group programmed while simultaneously bump testing (4 units at a time per MGC Pump Dock) using our GCT Manager software. As firmware updates become available, we can program each MGC Pump Dock to update units during bump testing and calibration. Facility safety standard compliance for single gas detectors is now easily achievable.

Event Data and Record Storage
In addition to performing tests, unit configurations and firmware updates, the MGC Pump Dock also stores important information about both the docking station and units tested. All tests performed on the docking station can be accessed from either the USB directly or using the GCT Manager software. Each bump test and calibration event is recorded and logged by date, time and serial number. Along with the test records, the individual event logs from each unit are saved. At the time of the test, the detector transmits its' event log to the memory. By default, the station will save the previous 10 event logs.

What's included with the Gas Clip MGC-S-DOCK

  • Gas Clip MGC-S-DOCK MGC Simple Dock Station

Ask a question about Gas Clip MGC-S-DOCK MGC Simple Dock Station

Customer Reviews for the Gas Clip MGC-S-DOCK

More Gas Clip Products