Work with this electrode that features a single ceramic junction in the outer reference cell. Suitable for chemicals, quality control and field applications, this double junction pH electrode has a PEI body with a BNC connector. Additionally, this electrodes pH sensing portion is designed with general-purpose glass.
Work with this electrode that features a single ceramic junction in the outer reference cell. Suitable for chemicals, quality control and field applications, this double junction pH electrode has a PEI body with a BNC connector. Additionally, this electrodes pH sensing portion is designed with general-purpose glass.
Features
General Purpose Glass Formulation
The measurement of pH at very high temperatures is detrimental to the sensitive glass bulb and will shorten the life of it. A pH electrode with general purpose (GP) glass will have a resistance of 100 MΩ at 77°F (25°C) while the resistance of LT glass is around 50 MΩ at 77°F (25°C). As the temperature of the glass decreases in the sample, the resistance of the LT glass will approach that of GP glass. If using GP glass, the resistance would increase above the optimum range, resulting in increased impedance and ultimately affecting the measurement. This electrode is suitable to use with samples that measure from 32 to 158°F (0 to 70°C).
PEI body
The body of this electrode is composed of polyetherimide (PEI) resin. The PEI body is suitable for a wide range of applications and excels in field measurements due to its durability. The shielding around the spherical glass tip minimizes breakage due to accidental bumping or dropping of the electrode. The PEI plastic is a high quality plastic that is chemically resistant to many aggressive chemicals.
Double junction reference
A double junction electrode has an internal compartment surrounding the reference wire. Silver ions are present in the electrolyte of the internal compartment, which houses the Ag/AgCl reference wire; the electrolyte outside this compartment is silver free. The double junction design means that virtually no silver from the electrode enters the sample. This design allows measurement in applications where silver ions in the sample are undesirable or silver precipitates on the junction are likely to form.
BNC connector
This electrode uses a BNC connector. This type of connector is universal in that it can be used on any pH meter that has the female BNC probe input. Other type of connectors include DIN, screw type, T-type, and 3.5mm to name a few. These types of connectors tend to be proprietary for a particular type of meter and are not interchangeable.
Applications
Measurement Range | pH |
Reference Cell Type | Double, Ag/AgC |
Junction Type/Flow Rate | Ceramic, single/15-20 μL/h |
Refill Electrolyte | 3.5 M KCl |
Body Material | PEI |
Tip/Shape | Spheric (diameter) |
Maximum Pressure | 0.1 bar |
Temperature Operating Range | 32 to 158°F (0 to 70°C) - GP |
Length | Body: 4.72" (120 mm) Overall: 6.9" (175.5 mm) |
Outer Diameter | 0.47" (12 mm) |
Cable | Coaxial; 3.3' (1 m) |
Connector Type | BNC |
Measurement Range | pH |
Reference Cell Type | Double, Ag/AgC |
Junction Type/Flow Rate | Ceramic, single/15-20 μL/h |
Refill Electrolyte | 3.5 M KCl |
Body Material | PEI |
Tip/Shape | Spheric (diameter) |
Maximum Pressure | 0.1 bar |
Temperature Operating Range | 32 to 158°F (0 to 70°C) - GP |
Length | Body: 4.72" (120 mm) Overall: 6.9" (175.5 mm) |
Outer Diameter | 0.47" (12 mm) |
Cable | Coaxial; 3.3' (1 m) |
Connector Type | BNC |