Accuenergy AcuDC 243-1000V-A0-P1-C-D DC Power Meter/Data Logger, 1000 V, 10 A, Modbus RTU

Modèle: AcuDC 243-1000V-A0-P1-C-D | No. de commande: AcuDC243-1000V-A0-P1-C-D

Accuenergy AcuDC 243-1000V-A0-P1-C-D DC Power Meter/Data Logger, 1000 V, 10 A, Modbus RTU

Modèle: AcuDC 243-1000V-A0-P1-C-D | No. de commande: AcuDC243-1000V-A0-P1-C-D

This DC power meter can measure a wide range of parameters such as voltage, current, power and energy and is ideal for monitoring and controlling energy flow in DC systems. Features a built-in MODBUS RTU and data logging capabilities.

This DC power meter can measure a wide range of parameters such as voltage, current, power and energy and is ideal for monitoring and controlling energy flow in DC systems. Features a built-in MODBUS RTU and data logging capabilities.

Prix spécial $476.14 CAD
Prix régulier $532.00 CAD
Disponibilité 1 Semaine
Quantité

Certificat d’étalonnage interne certifié ISO pour votre AcuDC 243-1000V-A0-P1-C-D

Certificat d’étalonnage interne certifié ISO pour votre AcuDC 243-1000V-A0-P1-C-D

Accuenergy AcuDC 243-1000V-A0-P1-C-D Offers

Specialty DC power and energy meter for monitoring solar PV energy generation, wind turbine power generation, transport systems, cell towers, power distribution in data centers, IT networks and other DC applications.

Features

  • Three-line high-definition LCD display provides easy to read real-time data directly on the meter front
  • Bi-directional current measurement
  • Over-range alarming feature for voltage and current
  • Built-in RS485 with MODBUS RTU protocol
  • Built-in power supply
  • Optional field-swappable modules
  • Large signals an be converted to smaller signal using optional analog output
  • Optional digital inputs for switch monitoring and relay outputs for remote controlling
  • All metering parameters can be recorded at intervals of 1 minute for 4 months
  • Standard DIN size (72x72mm) for easy installation

Applications

  • DC Energy Management Systems
  • Power Distribution for Telecommunication Room
  • Solar Photovoltaic Systems
  • Industrial DC Control Systems
  • Metallurgy and Electroplating Industries
  • Wind Power Generation
  • DC Excitation Systems
  • Light Rail Transit Systems
  • EV Charging Monitoring
  • Data Center
  • Cellular Tower Energy Monitoring

Accuenergy AcuDC 243-1000V-A0-P1-C-D Specifications

Voltage Range 0 to 1000VDC
Voltage Accuracy 0.2%
Voltage Resolution 0.001V
Current Range 0 to ±50,000A
Current Accuracy 0.2%
Current Resolution 0.001A
Power Range 0~±60000kW
Power Accuracy 0.5%
Power Resolution 0.001kW
Energy Range 0~9999999.99kWh
Energy Accuracy 0.5%
Energy Resolution 0.01kWh
Temperature Drift <100ppm/°C
Stability 0.5%/year
Power Supply 100-240Vac, 50/60Hz, 100-300Vdc
Dimensions 72×72×64.5mm (Cutout: 68×68mm) (2.8 × 2.8 × 2.5" (Cutout: 2.7×2.7")
Cliquer ici pour toutes les spécifications du Accuenergy AcuDC 243-1000V-A0-P1-C-D

What's included with the Accuenergy AcuDC 243-1000V-A0-P1-C-D

  • AcuDC 243-1000V-A0-P1-C-D DC Power Meter
  • Terminal Blocks
  • 4 x Installation Clips

Poser une question sur le Accuenergy AcuDC 243-1000V-A0-P1-C-D DC Power Meter/Data Logger, 1000 V, 10 A, Modbus RTU

Accuenergy AcuDC 243-1000V-A0-P1-C-D Offers

Specialty DC power and energy meter for monitoring solar PV energy generation, wind turbine power generation, transport systems, cell towers, power distribution in data centers, IT networks and other DC applications.

Features

  • Three-line high-definition LCD display provides easy to read real-time data directly on the meter front
  • Bi-directional current measurement
  • Over-range alarming feature for voltage and current
  • Built-in RS485 with MODBUS RTU protocol
  • Built-in power supply
  • Optional field-swappable modules
  • Large signals an be converted to smaller signal using optional analog output
  • Optional digital inputs for switch monitoring and relay outputs for remote controlling
  • All metering parameters can be recorded at intervals of 1 minute for 4 months
  • Standard DIN size (72x72mm) for easy installation

Applications

  • DC Energy Management Systems
  • Power Distribution for Telecommunication Room
  • Solar Photovoltaic Systems
  • Industrial DC Control Systems
  • Metallurgy and Electroplating Industries
  • Wind Power Generation
  • DC Excitation Systems
  • Light Rail Transit Systems
  • EV Charging Monitoring
  • Data Center
  • Cellular Tower Energy Monitoring

Accuenergy AcuDC 243-1000V-A0-P1-C-D Specifications

Voltage Range 0 to 1000VDC
Voltage Accuracy 0.2%
Voltage Resolution 0.001V
Current Range 0 to ±50,000A
Current Accuracy 0.2%
Current Resolution 0.001A
Power Range 0~±60000kW
Power Accuracy 0.5%
Power Resolution 0.001kW
Energy Range 0~9999999.99kWh
Energy Accuracy 0.5%
Energy Resolution 0.01kWh
Temperature Drift <100ppm/°C
Stability 0.5%/year
Power Supply 100-240Vac, 50/60Hz, 100-300Vdc
Dimensions 72×72×64.5mm (Cutout: 68×68mm) (2.8 × 2.8 × 2.5" (Cutout: 2.7×2.7")
Cliquer ici pour toutes les spécifications du Accuenergy AcuDC 243-1000V-A0-P1-C-D

What's included with the Accuenergy AcuDC 243-1000V-A0-P1-C-D

  • AcuDC 243-1000V-A0-P1-C-D DC Power Meter
  • Terminal Blocks
  • 4 x Installation Clips

Poser une question sur le Accuenergy AcuDC 243-1000V-A0-P1-C-D DC Power Meter/Data Logger, 1000 V, 10 A, Modbus RTU

Plus de produits Accuenergy