Veris H800 Solid Core Fixed Range: 0.25-200AAC Output: N.O. 1.0A at 30V

Model: H800

Veris H800 Solid Core Fixed Range: 0.25-200AAC Output: N.O. 1.0A at 30V

Model: H800

Hawkeye 800 go/no go current switches provide a cost-effective solution for monitoring status on unit vents, exhaust fans, recirculation pumps, and other fixed loads where belt loss is not a concern. Veris has applied new technology to the H800 models to achieve impressive improvement in turn-on levels, with the lowest turn-on current in the industry at a mere 150mA!

Hawkeye 800 go/no go current switches provide a cost-effective solution for monitoring status on unit vents, exhaust fans, recirculation pumps, and other fixed loads where belt loss is not a concern. Veris has applied new technology to the H800 models to achieve impressive improvement in turn-on levels, with the lowest turn-on current in the industry at a mere 150mA!

Sale Price $24.70 CAD
Regular Price $62.00 CAD
Availability 2 in Stock
Quantity

Veris H800 Offers

Features

  • More reliable for status than relays across auxiliary contacts
  • Ideal for direct-drive units, unit vents, fan coil units, exhaust fans, and other fixed loads
  • Great for lighting status–less expensive than 277 V relays
  • Removable mounting bracket provides installation flexibility
  • Mini solid-core fits in tight enclosures, saves valuable panel space
  • 100% solid-state, no moving parts to fail
  • Polarity insensitive output

Applications

  • Monitoring on/off status of electrical loads
  • Monitoring direct-drive units, exhaust fans, and other fixed loads
  • Verifying lighting run times

Veris H800 Specifications

Current Measurement Range: 0.25 to 200 A
Sensor Type: Current Switch, AC
Monitored Frequency Range: 50 to 60 Hz
Wire Dimensions: 0.7" (18 mm)
Operating Humidity: 10 to 90% RH, non-condensing
Temperature: -40 to 122°F (-40 to 50°C)
Output Specifications N.O. 1 A at 30 VAC/DC
Relay Coil Voltage: None
Construction: None
Contact Ratings: Resistive: None
Poles/Throw: None
Measurement Type AC Current
Mounting Solid Core
Electrical Wiring Dimensions 24 to 14 AWG (0.2 to 2.1 mm²)
Click here for complete specifications on the Veris H800

What's included with the Veris H800

  • Veris H800 Solid Core Fixed Range: 0.25-200AAC Output: N.O. 1.0A at 30V

Ask a question about Veris H800 Solid Core Fixed Range: 0.25-200AAC Output: N.O. 1.0A at 30V

Customer Reviews for the Veris H800

Veris H800 Offers

Features

  • More reliable for status than relays across auxiliary contacts
  • Ideal for direct-drive units, unit vents, fan coil units, exhaust fans, and other fixed loads
  • Great for lighting status–less expensive than 277 V relays
  • Removable mounting bracket provides installation flexibility
  • Mini solid-core fits in tight enclosures, saves valuable panel space
  • 100% solid-state, no moving parts to fail
  • Polarity insensitive output

Applications

  • Monitoring on/off status of electrical loads
  • Monitoring direct-drive units, exhaust fans, and other fixed loads
  • Verifying lighting run times

Veris H800 Specifications

Current Measurement Range: 0.25 to 200 A
Sensor Type: Current Switch, AC
Monitored Frequency Range: 50 to 60 Hz
Wire Dimensions: 0.7" (18 mm)
Operating Humidity: 10 to 90% RH, non-condensing
Temperature: -40 to 122°F (-40 to 50°C)
Output Specifications N.O. 1 A at 30 VAC/DC
Relay Coil Voltage: None
Construction: None
Contact Ratings: Resistive: None
Poles/Throw: None
Measurement Type AC Current
Mounting Solid Core
Electrical Wiring Dimensions 24 to 14 AWG (0.2 to 2.1 mm²)
Click here for complete specifications on the Veris H800

What's included with the Veris H800

  • Veris H800 Solid Core Fixed Range: 0.25-200AAC Output: N.O. 1.0A at 30V

Ask a question about Veris H800 Solid Core Fixed Range: 0.25-200AAC Output: N.O. 1.0A at 30V

Customer Reviews for the Veris H800

More Veris Products