Veris E31E84 Multi-Circuit/Panelboard Monitoring System, advanced with Ethernet, 84 branches

Model: E31E84

Veris E31E84 Multi-Circuit/Panelboard Monitoring System, advanced with Ethernet, 84 branches

Model: E31E84

The multi-circuit split-core panelboard system provides a solution for electrical load management and is ideal for retro-fit applications for dynamic loads. 84 branches.

The multi-circuit split-core panelboard system provides a solution for electrical load management and is ideal for retro-fit applications for dynamic loads. 84 branches.

Sale Price $9312.85 CAD
Regular Price $24143.00 CAD
Availability 2 to 3 Weeks
Quantity

Veris E31E84 Offers

The multi-circuit split-core panelboard system provides a solution for electrical load management and is ideal for retro-fit applications for dynamic loads. 84 branches.

Features

  • ANSI and IEC Class 1 metering system accuracy (1%, including branch CTs)
  • Built-in Ethernet and serial communication with Modbus, BACnet and SNMP protocols
  • Versatile support for any combination of 1, 2, 3 pole breakers
  • Phase angle measurements of every current and voltage input
  • Energy snapshots and demand measurements
  • Signed Power factor to indicate leading or lagging current
  • Signed Power to indicate import/export of energy
  • Reports voltage, current, power and energy for mains and branches; 1 product covers the whole panelboard
  • Monitors up to 92 circuits (84 branch circuits, two 3-phase main, 2 neutral) with 1 device, which saves space

Applications

  • Data Center Energy Management
  • Retrofit Branch Circuit Monitoring Into Existing Panels
  • Overload Protection and Infrastructure Management
  • Subtenant Billing
  • Load-Based Cost Allocation
  • Overload Protection
  • Load Management
  • Load Balancing
  • Lighting Circuit Monitoring

Veris E31E84 Specifications

Measurement Input Voltage 90 to 277 VAC, 50/60 Hz
Control Power Voltage 100 to 277 VAC, 50/60 Hz
Power/Energy IEC 62053-21 Class 1, ANSI C12.1-2008 (1% system accuracy, including 50 A or 100 A branch CTs)
Voltage ±0.5% of reading 90 to 277 V line-to-neutral
Sampling Frequency 2,560 Hz
Update Rate Modbus: 1.8 seconds; BACnet: 14 seconds; SNMP: 20 seconds
Overload Capability 22 kAIC
Physical Interface 10/100 Mbit Ethernet
Protocols Supported Modbus TCP, BACnet IP, SNMP
Physical Interface 2-wire RS-485
Protocols Supported Modbus RTU, BACnet MS/TP
Address 1 and 2
Baud Rate Selectable: 9600, 19200, 38400
Parity Selectable: NONE, ODD, EVEN
Communication Format 8 data-bits, 1 start-bit, 1 stop-bit
Ribbon Cable Support 2 each 4' (0.9 m) round ribbon cables ship standard; up to 20' (6 m) available
Operating Temperature 32 to 140°F (0 to 60°C) <95% RH non-condensing
Storage Temperature -40 to 158°F (-40 to 70°C)
Click here for complete specifications on the Veris E31E84

What's included with the Veris E31E84

  • Advanced Measurement Unit with Metal Housing
  • 2 x CT Adapter Boards
  • 2 x 4' (121.9 cm) Round Ribbon Cables CBL022
  • 42 x 50 A Split-Core CTs (E31CT0) To Monitor Up To 42 Branch Circuits
  • 2 x 3-phase Mains
  • 2 x Neutrals

Ask a question about Veris E31E84 Multi-Circuit/Panelboard Monitoring System, advanced with Ethernet, 84 branches

Customer Reviews for the Veris E31E84

Veris E31E84 Offers

The multi-circuit split-core panelboard system provides a solution for electrical load management and is ideal for retro-fit applications for dynamic loads. 84 branches.

Features

  • ANSI and IEC Class 1 metering system accuracy (1%, including branch CTs)
  • Built-in Ethernet and serial communication with Modbus, BACnet and SNMP protocols
  • Versatile support for any combination of 1, 2, 3 pole breakers
  • Phase angle measurements of every current and voltage input
  • Energy snapshots and demand measurements
  • Signed Power factor to indicate leading or lagging current
  • Signed Power to indicate import/export of energy
  • Reports voltage, current, power and energy for mains and branches; 1 product covers the whole panelboard
  • Monitors up to 92 circuits (84 branch circuits, two 3-phase main, 2 neutral) with 1 device, which saves space

Applications

  • Data Center Energy Management
  • Retrofit Branch Circuit Monitoring Into Existing Panels
  • Overload Protection and Infrastructure Management
  • Subtenant Billing
  • Load-Based Cost Allocation
  • Overload Protection
  • Load Management
  • Load Balancing
  • Lighting Circuit Monitoring

Veris E31E84 Specifications

Measurement Input Voltage 90 to 277 VAC, 50/60 Hz
Control Power Voltage 100 to 277 VAC, 50/60 Hz
Power/Energy IEC 62053-21 Class 1, ANSI C12.1-2008 (1% system accuracy, including 50 A or 100 A branch CTs)
Voltage ±0.5% of reading 90 to 277 V line-to-neutral
Sampling Frequency 2,560 Hz
Update Rate Modbus: 1.8 seconds; BACnet: 14 seconds; SNMP: 20 seconds
Overload Capability 22 kAIC
Physical Interface 10/100 Mbit Ethernet
Protocols Supported Modbus TCP, BACnet IP, SNMP
Physical Interface 2-wire RS-485
Protocols Supported Modbus RTU, BACnet MS/TP
Address 1 and 2
Baud Rate Selectable: 9600, 19200, 38400
Parity Selectable: NONE, ODD, EVEN
Communication Format 8 data-bits, 1 start-bit, 1 stop-bit
Ribbon Cable Support 2 each 4' (0.9 m) round ribbon cables ship standard; up to 20' (6 m) available
Operating Temperature 32 to 140°F (0 to 60°C) <95% RH non-condensing
Storage Temperature -40 to 158°F (-40 to 70°C)
Click here for complete specifications on the Veris E31E84

What's included with the Veris E31E84

  • Advanced Measurement Unit with Metal Housing
  • 2 x CT Adapter Boards
  • 2 x 4' (121.9 cm) Round Ribbon Cables CBL022
  • 42 x 50 A Split-Core CTs (E31CT0) To Monitor Up To 42 Branch Circuits
  • 2 x 3-phase Mains
  • 2 x Neutrals

Ask a question about Veris E31E84 Multi-Circuit/Panelboard Monitoring System, advanced with Ethernet, 84 branches

Customer Reviews for the Veris E31E84

More Veris Products