Used with pitot tubes (sold separately) to measure quickly and accurately measure differential and static pressure and duct velocity, this high-performance handheld micromanometer is easy to operate. In addition, it can calculate flow, makes HVAC/R pressure measurements, and has data logging capabilities.
Used with pitot tubes (sold separately) to measure quickly and accurately measure differential and static pressure and duct velocity, this high-performance handheld micromanometer is easy to operate. In addition, it can calculate flow, makes HVAC/R pressure measurements, and has data logging capabilities.
Features
Applications
Static/Differential Pressure | Range: -15 to 15 "H2O (-28 to 28 mm Hg, -3735 to 3735 Pa) Accuracy: ±1% of reading ±0.0005 "H2O (±0.01 mm Hg, ±1 Pa) Resolution: 0.001 "H2O (0.1 Pa, 0.01 mmHg) |
Velocity (Pitot Tube Required) | Range2: 250 to 15,500 ft/min (1.27 to 78.7 m/s) Accuracy3: ±1.5% at 2000 ft/min (10.16 m/s) Resolution: 1 ft/min (0.1 m/s) |
Duct Size | 1 to 500" in increments of 0.1" (2.5 to 1270 cm in increments of 0.1 cm) |
Volumetric Flow Rate | Actual rate is a function of velocity, pressure, duct size, and K factor |
Data Storage | 12,700 samples and 100 test IDs |
Logging Interval | 1 second to 1 hour |
Time Constant | User selectable |
Environmental Conditions | Operating temperature: 40 to 113°F (5 to 45°C) Storage temperature: -4 to 140°F (-20 to 60°C) |
Power Requirements | 4 x AA batteries or optional AC adapter (sold separately) |
Dimensions | 3.3 x 7 x 1.8" (8.4 x 17.8 x 4.4 cm) |
Weight | 0.6 lbs (0.27 kg) |
Click on a category to view a selection of compatible accessories with the TSI/Alnor 5825 DP-Calc High-Performance Micromanometer, 250 to 15,500 ft/min.
Static/Differential Pressure | Range: -15 to 15 "H2O (-28 to 28 mm Hg, -3735 to 3735 Pa) Accuracy: ±1% of reading ±0.0005 "H2O (±0.01 mm Hg, ±1 Pa) Resolution: 0.001 "H2O (0.1 Pa, 0.01 mmHg) |
Velocity (Pitot Tube Required) | Range2: 250 to 15,500 ft/min (1.27 to 78.7 m/s) Accuracy3: ±1.5% at 2000 ft/min (10.16 m/s) Resolution: 1 ft/min (0.1 m/s) |
Duct Size | 1 to 500" in increments of 0.1" (2.5 to 1270 cm in increments of 0.1 cm) |
Volumetric Flow Rate | Actual rate is a function of velocity, pressure, duct size, and K factor |
Data Storage | 12,700 samples and 100 test IDs |
Logging Interval | 1 second to 1 hour |
Time Constant | User selectable |
Environmental Conditions | Operating temperature: 40 to 113°F (5 to 45°C) Storage temperature: -4 to 140°F (-20 to 60°C) |
Power Requirements | 4 x AA batteries or optional AC adapter (sold separately) |
Dimensions | 3.3 x 7 x 1.8" (8.4 x 17.8 x 4.4 cm) |
Weight | 0.6 lbs (0.27 kg) |
Click on a category to view a selection of compatible accessories with the TSI/Alnor 5825 DP-Calc High-Performance Micromanometer, 250 to 15,500 ft/min.