This loop calibrator features mA sourcing, simulation and measurement. It has a 24V loop power supply and selectable step or ramp outputs. This product includes an ISO Certificate with full Data and Uncertainties.
This loop calibrator features mA sourcing, simulation and measurement. It has a 24V loop power supply and selectable step or ramp outputs. This product includes an ISO Certificate with full Data and Uncertainties.
This loop calibrator sources and measures mA. The R5820 features a 24V loop power supply, selectable step or ramp outputs and a large easy-to-read 5-digit LCD display.
This product includes an ISO Certificate with full Data and Uncertainties.
Features
DC Voltage Measurement | |
Range | 28V |
Output Range | -0.200 to 28.000V |
Resolution | 1mV |
Accuracy | ±0.02% reading ± 2mV |
DC Current Measurement | |
Range | 20mA |
Output Range | -1.000 to 22.000mA |
Resolution | 0.001mA |
Accuracy | ±0.02% reading + 4µA |
Loop Current Measurement | |
Range | 20mA |
Output Range | 0.000 to 22.000mA |
Resolution | 0.001mA |
Accuracy | ±0.02% reading + 4µA |
Current Output | |
Range | 20mA |
Output Range | 0.000 to 22.000mA |
Resolution | 0.001mA |
Accuracy | ±0.05% setting + 4µA |
Analog Transducer Output | |
Range | -20mA |
Output Range | 0.000 to -22.000mA |
Resolution | 0.001mA |
Accuracy | ±0.05% setting + 4µA |
Loop Power | 24V |
Accuracy | ±10% |
General Specifications | |
Display | 5-Digit LCD |
Kick Stand | Yes |
Battery Life | Approx. 20 hours |
Power Supply | 2 AA Batteries |
Auto shut off | Yes (after 15 mins/off) |
Low Battery Indicator | Yes |
Replaceable Test Leads | Yes |
Product Certifications | CE |
Operating Temperature | 32 to 122°F (0 to 50°C) |
Operating Humidity Range | 0 to 85% |
Storage Temperature | 14 to 122°F (-10 to 50°C) |
Dimensions | 7.1 x 3.5 x 1.9" (180 x 90 x 47mm) |
Weight | 8.2oz (500g) |
Click on a category to view a selection of compatible accessories with the REED R5820-NIST Loop Calibrator, .
DC Voltage Measurement | |
Range | 28V |
Output Range | -0.200 to 28.000V |
Resolution | 1mV |
Accuracy | ±0.02% reading ± 2mV |
DC Current Measurement | |
Range | 20mA |
Output Range | -1.000 to 22.000mA |
Resolution | 0.001mA |
Accuracy | ±0.02% reading + 4µA |
Loop Current Measurement | |
Range | 20mA |
Output Range | 0.000 to 22.000mA |
Resolution | 0.001mA |
Accuracy | ±0.02% reading + 4µA |
Current Output | |
Range | 20mA |
Output Range | 0.000 to 22.000mA |
Resolution | 0.001mA |
Accuracy | ±0.05% setting + 4µA |
Analog Transducer Output | |
Range | -20mA |
Output Range | 0.000 to -22.000mA |
Resolution | 0.001mA |
Accuracy | ±0.05% setting + 4µA |
Loop Power | 24V |
Accuracy | ±10% |
General Specifications | |
Display | 5-Digit LCD |
Kick Stand | Yes |
Battery Life | Approx. 20 hours |
Power Supply | 2 AA Batteries |
Auto shut off | Yes (after 15 mins/off) |
Low Battery Indicator | Yes |
Replaceable Test Leads | Yes |
Product Certifications | CE |
Operating Temperature | 32 to 122°F (0 to 50°C) |
Operating Humidity Range | 0 to 85% |
Storage Temperature | 14 to 122°F (-10 to 50°C) |
Dimensions | 7.1 x 3.5 x 1.9" (180 x 90 x 47mm) |
Weight | 8.2oz (500g) |
Click on a category to view a selection of compatible accessories with the REED R5820-NIST Loop Calibrator, .