The pressure calibrator helps create tests, log results and import data to a PC. The FieldLab comes with a carrying case for protection and transport.
The pressure calibrator helps create tests, log results and import data to a PC. The FieldLab comes with a carrying case for protection and transport.
If you want to create tests, log results and move data to your PC, choose the Ralston FLP1-GT-QM-W1 FieldLab Digital Pressure Calibrator. The calibrator is made of strong stainless steel and reinforced polyamide with IP67 ingress protection for durability and comes with a carrying case to make it easy to bring with you.
Features
Product Height | 2.5" (64 mm) |
Accuracy | ±0.02% of full scale (0 to 20% of full scale), ±0.1% of reading (20 to 100% of full scale) |
Input(s) | USB Type-B |
Battery Life | 1,000 hours |
Operating Temperature | 14 to 122°F (-10 to 50°C) |
Number Of Batteries Required | 1 |
Approvals | CSA C22.2 No. 61010-1, UL/IEC/EN/AS No. 61010-1, North America - Class 1 Division 1 Groups A to D, T4, ATEX - Ex II 1 G Ex ia IICT4 Ga, IECEx - Ex ia IICT4 Ga, UN/DOT 38.3 (battery), Pressure Equipment Directive 2014/68/EU, Low Voltage Directive 2014/35/EU, Electromagnetic Compatibility Directive 2014/30/EU |
Product Length | 9" (23 cm) |
Product Width | 5" (13 cm) |
Pressure Measurement Range | 5,000 psi; Burst pressure: 20,000 psi |
Storage Temperature | -20 to 167°F (-29 to 75°C) |
Battery Type | Other |
Rechargeable Battery | Yes |
Product Weight | 2.58 lbs (1.17 kg) |
Power Source | Battery powered |
Power Requirements | 90 to 264 VAC, 50 to 60 Hz |
Product Height | 2.5" (64 mm) |
Accuracy | ±0.02% of full scale (0 to 20% of full scale), ±0.1% of reading (20 to 100% of full scale) |
Input(s) | USB Type-B |
Battery Life | 1,000 hours |
Operating Temperature | 14 to 122°F (-10 to 50°C) |
Number Of Batteries Required | 1 |
Approvals | CSA C22.2 No. 61010-1, UL/IEC/EN/AS No. 61010-1, North America - Class 1 Division 1 Groups A to D, T4, ATEX - Ex II 1 G Ex ia IICT4 Ga, IECEx - Ex ia IICT4 Ga, UN/DOT 38.3 (battery), Pressure Equipment Directive 2014/68/EU, Low Voltage Directive 2014/35/EU, Electromagnetic Compatibility Directive 2014/30/EU |
Product Length | 9" (23 cm) |
Product Width | 5" (13 cm) |
Pressure Measurement Range | 5,000 psi; Burst pressure: 20,000 psi |
Storage Temperature | -20 to 167°F (-29 to 75°C) |
Battery Type | Other |
Rechargeable Battery | Yes |
Product Weight | 2.58 lbs (1.17 kg) |
Power Source | Battery powered |
Power Requirements | 90 to 264 VAC, 50 to 60 Hz |