The pressure pump includes a pressure reference, process connection and hose. The pump works with air, inert gas and natural gas.
The pressure pump includes a pressure reference, process connection and hose. The pump works with air, inert gas and natural gas.
Trust the reliability of the Ralston DCAP-1KPSIG-FL Pressure Test Pump with 1,000 psi FieldLab pressure reference, which works with air, inert gas and natural gas. The pump is made of anodized aluminum, brass and stainless steel for strength and features Buna-N and Delrin seal material for proper protection.
Features
Product Length | Pump: 5" (13 cm); Pressure reference: 9" (23 cm); Process connection: 1.29" (33 mm); Hose: 3' (0.9 m) |
Product Width | Pump: 3" (77 mm); Pressure reference: 5" (13 cm); Process connection: 0.56" (15 mm) |
Battery Type | Other |
Seal Type | Buna-N and Delrin (pump); Teflon and Viton (pressure reference); Buna-N (process connection) |
Operating Temperature | Hose: 0 to 140°F (-18 to 60°C); Pressure reference: 14 to 133°F (-10 to 50°C); Process connection: 0 to 225°F (-18 to 105°C); Hose: -40 to 140°F (-40 to 60°C) |
Power Source | Pneumatic |
Rechargeable Battery | Yes |
Product Weight | Pump: 1.75 lbs (795 g); Pressure reference: 2.56 lbs (1.16 kg) |
Power Requirements | 90 to 264 VAC, 50 to 60 Hz |
Approvals | Pressure reference: CSA C22.2 No. 61010-1, UL/IEC/EN/AS No. 61010-1, North America - Class 1 Division 1 Groups A to D, T4, ATEX - Ex II 1 G Ex ia IICT4 Ga, IECEx to Ex ia IICT4 Ga, UN/DOT 38.3 (battery), Pressure Equipment Directive 2014/68/EU, Low Voltage Directive 2014/35/EU, Electromagnetic Compatibility Directive 2014/30/EU |
Product Height | Pump: 10.5" (27 cm); Pressure reference: 2.5" (64 mm) |
Pressure Limit | 650 psi (pump), 1,000 psi (pressure reference), 5,000 psi (process connection), 6,900 psi (hose); Burst Pressure: 2,600 psi (pump), 4,000 psi (pressure reference), 27,000 psi (hose) |
Adjustment Resolution | 0.001 psi |
Battery Life | 1,000 hours |
Number Of Batteries Required | 1 |
Product Length | Pump: 5" (13 cm); Pressure reference: 9" (23 cm); Process connection: 1.29" (33 mm); Hose: 3' (0.9 m) |
Product Width | Pump: 3" (77 mm); Pressure reference: 5" (13 cm); Process connection: 0.56" (15 mm) |
Battery Type | Other |
Seal Type | Buna-N and Delrin (pump); Teflon and Viton (pressure reference); Buna-N (process connection) |
Operating Temperature | Hose: 0 to 140°F (-18 to 60°C); Pressure reference: 14 to 133°F (-10 to 50°C); Process connection: 0 to 225°F (-18 to 105°C); Hose: -40 to 140°F (-40 to 60°C) |
Power Source | Pneumatic |
Rechargeable Battery | Yes |
Product Weight | Pump: 1.75 lbs (795 g); Pressure reference: 2.56 lbs (1.16 kg) |
Power Requirements | 90 to 264 VAC, 50 to 60 Hz |
Approvals | Pressure reference: CSA C22.2 No. 61010-1, UL/IEC/EN/AS No. 61010-1, North America - Class 1 Division 1 Groups A to D, T4, ATEX - Ex II 1 G Ex ia IICT4 Ga, IECEx to Ex ia IICT4 Ga, UN/DOT 38.3 (battery), Pressure Equipment Directive 2014/68/EU, Low Voltage Directive 2014/35/EU, Electromagnetic Compatibility Directive 2014/30/EU |
Product Height | Pump: 10.5" (27 cm); Pressure reference: 2.5" (64 mm) |
Pressure Limit | 650 psi (pump), 1,000 psi (pressure reference), 5,000 psi (process connection), 6,900 psi (hose); Burst Pressure: 2,600 psi (pump), 4,000 psi (pressure reference), 27,000 psi (hose) |
Adjustment Resolution | 0.001 psi |
Battery Life | 1,000 hours |
Number Of Batteries Required | 1 |