Invest in safety with this mini hydrogen sulfide sensor, equipped with visual and audio alarms to immediately alert users to nearby high gas levels. In addition, compatible with the MicroRAE gas detector, this H2S sensor is a trusted choice among professionals across numerous industries.
Invest in safety with this mini hydrogen sulfide sensor, equipped with visual and audio alarms to immediately alert users to nearby high gas levels. In addition, compatible with the MicroRAE gas detector, this H2S sensor is a trusted choice among professionals across numerous industries.
Introducing a cutting-edge breakthrough in gas detection technology that sets a new benchmark for safety and accuracy, this hydrogen sulfide sensor provides precise and dependable monitoring of H2S gas levels. Hydrogen sulfide is a toxic and flammable gas commonly found in industrial processes, wastewater treatment facilities, and confined spaces, where this sensor performs at its best. Furthermore, exposure to elevated H2S levels poses serious health risks, making this sensor's reliable detection crucial for ensuring worker safety and environmental compliance.
Features
Applications
Gas Detected | Hydrogen sulfide (H2S) |
Measurement Range | 0 to 100 PPM |
Resolution | 0.1 ppm |
Bias/Equilibration | 0 V |
Sensor Type | Electrochemical |
Pressure Range | Atmospheric ±10% |
Cross-Sensitivity Data, Mini-H2S Sensor | CO Concentration: 50 ppm Response: 1.5 ppm C2/H5/OH Concentration: 5000 ppm Response: ±1.5 ppm SO2 Concentration: 20 ppm Response: <4 ppm NO Concentration: 50 ppm Response: 6 ppm NO2 Concentration: 10 ppm Response: -2.5 ppm H2 Concentration: 400 ppm Response: 4 ppm Note: The cross-sensitivity may fluctuate between ±30% and may differ from batch to batch or over the sensor's lifetime. The cross-sensitivities include, but are not limited to, the above gases. |
Calibration Gas | 25 ppm H2S, balance nitrogen |
Environmental Conditions | Operating temperature: -4 to 122°F (-20 to 50°C) Storage temperature: 32 to 68°F (0 to 20°C) Operating humidity: 15 to 90% RH non-condensing |
Lifetime | Storage: 6 months in sealed container Operating: 24 months in air |
Certifications | ATEX, CSA, IECEx, CE, IP rating for water and dust resistance |
Gas Detected | Hydrogen sulfide (H2S) |
Measurement Range | 0 to 100 PPM |
Resolution | 0.1 ppm |
Bias/Equilibration | 0 V |
Sensor Type | Electrochemical |
Pressure Range | Atmospheric ±10% |
Cross-Sensitivity Data, Mini-H2S Sensor | CO Concentration: 50 ppm Response: 1.5 ppm C2/H5/OH Concentration: 5000 ppm Response: ±1.5 ppm SO2 Concentration: 20 ppm Response: <4 ppm NO Concentration: 50 ppm Response: 6 ppm NO2 Concentration: 10 ppm Response: -2.5 ppm H2 Concentration: 400 ppm Response: 4 ppm Note: The cross-sensitivity may fluctuate between ±30% and may differ from batch to batch or over the sensor's lifetime. The cross-sensitivities include, but are not limited to, the above gases. |
Calibration Gas | 25 ppm H2S, balance nitrogen |
Environmental Conditions | Operating temperature: -4 to 122°F (-20 to 50°C) Storage temperature: 32 to 68°F (0 to 20°C) Operating humidity: 15 to 90% RH non-condensing |
Lifetime | Storage: 6 months in sealed container Operating: 24 months in air |
Certifications | ATEX, CSA, IECEx, CE, IP rating for water and dust resistance |