Obvius A8332-8F2D Flex I/O Module

Model: A8332-8F2D

Obvius A8332-8F2D Flex I/O Module

Model: A8332-8F2D

A universal remote I/O module with eight user-selectable inputs for pulse, analog, and resistive output devices, that allows a way to collect data from meters or sensors and bring that information into a Modbus network or energy monitoring system.

A universal remote I/O module with eight user-selectable inputs for pulse, analog, and resistive output devices, that allows a way to collect data from meters or sensors and bring that information into a Modbus network or energy monitoring system.

Discontinued!

This product has been discontinued and is no longer available. There is no direct replacement. Don't worry, we have some options to help you find what you need:

Visit our Electricity category for similar products.

Or let's do a search and help you find what you need:


Obvius A8332-8F2D Offers

Features

  • Designed specifically for metering applications
  • Easily add meters and sensor to a Modbus network
  • 8x user selectable inputs
  • 2x output relays
  • 2x pulse replicator
  • Non-volatile memory
  • LEDs for visual verification/status
  • Din or wall mount for easy installation
  • Field upgradable firmware

Compatibility

The Flex I/O is compatible with virtually any PLC or Modbus Master, allowing for the flexibility to use it in existing Modbus networks. Use with the Obvius AcquiSuite and take advantage of plug-and-play communication or use with the Obvius ModHopper for wireless communication.

Applications

  • Converting analog, resistive and pulse inputs to Modbus
  • Utility submetering (electric, gas, water, etc.)
  • Cost allocation
  • Measurement and verification
  • Benchmark building energy usage
  • Relay outputs for demand control
  • Environmental monitoring
  • Track energy use and peak demand for demand response
  • DC current monitoring for renewable energy

Obvius A8332-8F2D Specifications

Inputs
Modes Voltage:
0 to 10 VDC (min/max/average/instantaneous data)
Accuracy: ±0.25% of full scale at 68°F (20°C)

Current:
4 to 20 mA (min/max/average/instantaneous data)
Accuracy ±0.25% of full scale at 68°F (20°C)

Resistance:
4 to 20 mA (min/max/average/instantaneous data)

Pulse:
Intended for use with dry contact outputs (consumption/rate/runtime/status)
Standard and KYZ modes for form A and C relay outputs
Input terminals supplies 5 V at 5 mA sense voltage to detect contact closures
Maximum rate: 10 Hz, minimum pulse width 50 ms
Adjustable contact closure threshold: 100 Ω to 5 kΩ
Serial Port RS-485 two wire, 19200 or 9600 baud, 8N1
I/O 8 Flex IO inputs with user selectable modes: voltage, current, resistance, pulse and status
Isolation Pulse outputs and RS-485 port are isolated to 1500 VDC;
Power input, RS-232 and analog/pulse inputs are non-isolated
Outputs
Relays 2x, dry contact (opto-fet) 30 VDC, 150 mA max
Communication
Protocols Modbus/RTU
General Specifications
Processor ARM7, field upgradable firmware
LEDs 8x input status LEDs (red), 2x Modbus TX/RX (yellow), 1 power/alive status (green)
Memory Pulse count and runtime values are stored in non-volatile memory
Power Supply 24 VDC, 200 mA but not to exceed 8 A, required
Operating Temperature -22 to 158°F (-30 to 70°C), 0 to 95% RH, non-condensing
Altitude 6561.58' (2000 m) maximum
Pollution Degree 2
Dimensions 4.13 x 3.39 x 1.18" (105 x 86 x 30 mm)
Weight 3.7 oz (105 g)
Emissions FCC CFR 47 Part 15, Class A, EN 61000, EN 61326
Safety UL61010 Recognized, EN61010
Click here for complete specifications on the Obvius A8332-8F2D

What's included with the Obvius A8332-8F2D

  • Obvius A8332-8F2D Flex I/O Module

Ask a question about Obvius A8332-8F2D Flex I/O Module

Customer Reviews for the Obvius A8332-8F2D

Obvius A8332-8F2D Offers

Features

  • Designed specifically for metering applications
  • Easily add meters and sensor to a Modbus network
  • 8x user selectable inputs
  • 2x output relays
  • 2x pulse replicator
  • Non-volatile memory
  • LEDs for visual verification/status
  • Din or wall mount for easy installation
  • Field upgradable firmware

Compatibility

The Flex I/O is compatible with virtually any PLC or Modbus Master, allowing for the flexibility to use it in existing Modbus networks. Use with the Obvius AcquiSuite and take advantage of plug-and-play communication or use with the Obvius ModHopper for wireless communication.

Applications

  • Converting analog, resistive and pulse inputs to Modbus
  • Utility submetering (electric, gas, water, etc.)
  • Cost allocation
  • Measurement and verification
  • Benchmark building energy usage
  • Relay outputs for demand control
  • Environmental monitoring
  • Track energy use and peak demand for demand response
  • DC current monitoring for renewable energy

Obvius A8332-8F2D Specifications

Inputs
Modes Voltage:
0 to 10 VDC (min/max/average/instantaneous data)
Accuracy: ±0.25% of full scale at 68°F (20°C)

Current:
4 to 20 mA (min/max/average/instantaneous data)
Accuracy ±0.25% of full scale at 68°F (20°C)

Resistance:
4 to 20 mA (min/max/average/instantaneous data)

Pulse:
Intended for use with dry contact outputs (consumption/rate/runtime/status)
Standard and KYZ modes for form A and C relay outputs
Input terminals supplies 5 V at 5 mA sense voltage to detect contact closures
Maximum rate: 10 Hz, minimum pulse width 50 ms
Adjustable contact closure threshold: 100 Ω to 5 kΩ
Serial Port RS-485 two wire, 19200 or 9600 baud, 8N1
I/O 8 Flex IO inputs with user selectable modes: voltage, current, resistance, pulse and status
Isolation Pulse outputs and RS-485 port are isolated to 1500 VDC;
Power input, RS-232 and analog/pulse inputs are non-isolated
Outputs
Relays 2x, dry contact (opto-fet) 30 VDC, 150 mA max
Communication
Protocols Modbus/RTU
General Specifications
Processor ARM7, field upgradable firmware
LEDs 8x input status LEDs (red), 2x Modbus TX/RX (yellow), 1 power/alive status (green)
Memory Pulse count and runtime values are stored in non-volatile memory
Power Supply 24 VDC, 200 mA but not to exceed 8 A, required
Operating Temperature -22 to 158°F (-30 to 70°C), 0 to 95% RH, non-condensing
Altitude 6561.58' (2000 m) maximum
Pollution Degree 2
Dimensions 4.13 x 3.39 x 1.18" (105 x 86 x 30 mm)
Weight 3.7 oz (105 g)
Emissions FCC CFR 47 Part 15, Class A, EN 61000, EN 61326
Safety UL61010 Recognized, EN61010
Click here for complete specifications on the Obvius A8332-8F2D

What's included with the Obvius A8332-8F2D

  • Obvius A8332-8F2D Flex I/O Module

Ask a question about Obvius A8332-8F2D Flex I/O Module

Customer Reviews for the Obvius A8332-8F2D

More Obvius Products