Michell XZR200 Oxygen Analyzer with 15.7";; probe, 752°F, 15' cable with fittings

Model: XZR200 | Order No: XZR200-B2-C2-D2

Michell XZR200 Oxygen Analyzer with 15.7";; probe, 752°F, 15' cable with fittings

Model: XZR200 | Order No: XZR200-B2-C2-D2

Measures oxygen in closed systems, this oxygen analyzer with 15.7";; (400 mm) probe has a 15' (4.57 m) cable with fittings. Takes oxygen concentration measurement with temperatures of -148 to 752°F (-100 to 400°C). In addition, it uses a unique closed-loop measurement system.

Measures oxygen in closed systems, this oxygen analyzer with 15.7";; (400 mm) probe has a 15' (4.57 m) cable with fittings. Takes oxygen concentration measurement with temperatures of -148 to 752°F (-100 to 400°C). In addition, it uses a unique closed-loop measurement system.

Your Price $3568.00 CAD
Availability 2 to 3 Weeks
Quantity

Michell XZR200 Offers

It can be configured to output measuring ranges of 0 to 25% O2 or 0 to 100% O2.

Features

  • Zirconium dioxide technology
  • High accuracy linear output
  • Configurable outputs; 4 to 20 mA and 0 to 10 V DC or RS232 comms interface
  • Selectable output measuring ranges; 0 to 25% O2 or 0 to 100% O2 or fully adjustable via RS232
  • Can be calibrated in fresh air (20.7% O2) or in any other known O2 concentration
  • Housed in a sealed die-cast aluminium housing with attached oxygen sensor probe and amphenol Ecomate connector
  • Works at temperatures from -148 to 752°F (-100 to 400°C)

Applications

  • Combustion control of industrial boilers
  • Burning oil, gas, coal or biomass
  • Incubators
  • Composting probes and welding equipment

Michell XZR200 Specifications

Supply Voltage: 24 VDC ±10%
Current: 500 mA maximum at 24 VDC
Output Digital: RS232
Analogue: 4 to 20 mA; load 600 Ω maximum
0 to 10 VDC; load 10 kΩ minimum
Housing Temperature Limits Storage/Operating: 14 to 185°F (-10 to 85°C)
Permissible Gas Temperatures (Probe Tip) Standard: -148 to 482°F (-100 to 250°C)
High: -148 to 752°F (-100 to 400°C)
Gas Flow Rate: 0 to 10 m/s
Probe Length 15.7"; (400 mm)
Permissible Acceleration Repetitive: 0.01 lbs (5 g)
Incidental: 0.07 lbs (30 g)
Oxygen Range Analogue output: 0.11 to 25% O2, 0.11 to 100% O2
RS232 output: 0.11 and 100% O2
Accuracy After Calibration 1% O2
Repeatability After Calibration 0.5% O2
Output Resolution Analogue 4 to 20 mA: 0.01 mA
Analogue 0 to 10 VDC: 0.01 V
Digital RS232: 0.01% O2
Response Time < 15 seconds
Warm Up Time (Prior To Sensor Operation) 60 seconds
Output Stabilisation Time ~ 180 seconds
Cable Length 15' (4.57 m)

What's included with the Michell XZR200

Analyzer

Cable

Fittings

Ask a question about Michell XZR200 Oxygen Analyzer with 15.7";; probe, 752°F, 15' cable with fittings

Customer Reviews for the Michell XZR200

Michell XZR200 Offers

It can be configured to output measuring ranges of 0 to 25% O2 or 0 to 100% O2.

Features

  • Zirconium dioxide technology
  • High accuracy linear output
  • Configurable outputs; 4 to 20 mA and 0 to 10 V DC or RS232 comms interface
  • Selectable output measuring ranges; 0 to 25% O2 or 0 to 100% O2 or fully adjustable via RS232
  • Can be calibrated in fresh air (20.7% O2) or in any other known O2 concentration
  • Housed in a sealed die-cast aluminium housing with attached oxygen sensor probe and amphenol Ecomate connector
  • Works at temperatures from -148 to 752°F (-100 to 400°C)

Applications

  • Combustion control of industrial boilers
  • Burning oil, gas, coal or biomass
  • Incubators
  • Composting probes and welding equipment

Michell XZR200 Specifications

Supply Voltage: 24 VDC ±10%
Current: 500 mA maximum at 24 VDC
Output Digital: RS232
Analogue: 4 to 20 mA; load 600 Ω maximum
0 to 10 VDC; load 10 kΩ minimum
Housing Temperature Limits Storage/Operating: 14 to 185°F (-10 to 85°C)
Permissible Gas Temperatures (Probe Tip) Standard: -148 to 482°F (-100 to 250°C)
High: -148 to 752°F (-100 to 400°C)
Gas Flow Rate: 0 to 10 m/s
Probe Length 15.7"; (400 mm)
Permissible Acceleration Repetitive: 0.01 lbs (5 g)
Incidental: 0.07 lbs (30 g)
Oxygen Range Analogue output: 0.11 to 25% O2, 0.11 to 100% O2
RS232 output: 0.11 and 100% O2
Accuracy After Calibration 1% O2
Repeatability After Calibration 0.5% O2
Output Resolution Analogue 4 to 20 mA: 0.01 mA
Analogue 0 to 10 VDC: 0.01 V
Digital RS232: 0.01% O2
Response Time < 15 seconds
Warm Up Time (Prior To Sensor Operation) 60 seconds
Output Stabilisation Time ~ 180 seconds
Cable Length 15' (4.57 m)

What's included with the Michell XZR200

Analyzer

Cable

Fittings

Ask a question about Michell XZR200 Oxygen Analyzer with 15.7";; probe, 752°F, 15' cable with fittings