Measures oxygen in closed systems, this oxygen analyzer with 15.7";; (400 mm) probe has a 15' (4.57 m) cable with fittings. Takes oxygen concentration measurement with temperatures of -148 to 752°F (-100 to 400°C). In addition, it uses a unique closed-loop measurement system.
Measures oxygen in closed systems, this oxygen analyzer with 15.7";; (400 mm) probe has a 15' (4.57 m) cable with fittings. Takes oxygen concentration measurement with temperatures of -148 to 752°F (-100 to 400°C). In addition, it uses a unique closed-loop measurement system.
It can be configured to output measuring ranges of 0 to 25% O2 or 0 to 100% O2.
Features
Applications
Supply | Voltage: 24 VDC ±10% Current: 500 mA maximum at 24 VDC |
Output | Digital: RS232 Analogue: 4 to 20 mA; load 600 Ω maximum 0 to 10 VDC; load 10 kΩ minimum |
Housing Temperature Limits | Storage/Operating: 14 to 185°F (-10 to 85°C) |
Permissible Gas Temperatures (Probe Tip) | Standard: -148 to 482°F (-100 to 250°C) High: -148 to 752°F (-100 to 400°C) Gas Flow Rate: 0 to 10 m/s |
Probe Length | 15.7"; (400 mm) |
Permissible Acceleration | Repetitive: 0.01 lbs (5 g) Incidental: 0.07 lbs (30 g) |
Oxygen Range | Analogue output: 0.11 to 25% O2, 0.11 to 100% O2 RS232 output: 0.11 and 100% O2 |
Accuracy After Calibration | 1% O2 |
Repeatability After Calibration | 0.5% O2 |
Output Resolution | Analogue 4 to 20 mA: 0.01 mA Analogue 0 to 10 VDC: 0.01 V Digital RS232: 0.01% O2 |
Response Time | < 15 seconds |
Warm Up Time (Prior To Sensor Operation) | 60 seconds |
Output Stabilisation Time | ~ 180 seconds |
Cable Length | 15' (4.57 m) |
Analyzer
Cable
Fittings
Supply | Voltage: 24 VDC ±10% Current: 500 mA maximum at 24 VDC |
Output | Digital: RS232 Analogue: 4 to 20 mA; load 600 Ω maximum 0 to 10 VDC; load 10 kΩ minimum |
Housing Temperature Limits | Storage/Operating: 14 to 185°F (-10 to 85°C) |
Permissible Gas Temperatures (Probe Tip) | Standard: -148 to 482°F (-100 to 250°C) High: -148 to 752°F (-100 to 400°C) Gas Flow Rate: 0 to 10 m/s |
Probe Length | 15.7"; (400 mm) |
Permissible Acceleration | Repetitive: 0.01 lbs (5 g) Incidental: 0.07 lbs (30 g) |
Oxygen Range | Analogue output: 0.11 to 25% O2, 0.11 to 100% O2 RS232 output: 0.11 and 100% O2 |
Accuracy After Calibration | 1% O2 |
Repeatability After Calibration | 0.5% O2 |
Output Resolution | Analogue 4 to 20 mA: 0.01 mA Analogue 0 to 10 VDC: 0.01 V Digital RS232: 0.01% O2 |
Response Time | < 15 seconds |
Warm Up Time (Prior To Sensor Operation) | 60 seconds |
Output Stabilisation Time | ~ 180 seconds |
Cable Length | 15' (4.57 m) |
Analyzer
Cable
Fittings