Measures both dew point and moisture content, this dew-point transmitter has -166 to 68°F (-110 to 20°C) dp range and a standard HDPE guard for protection against fine particulates with <10 µm size. In addition, it is simple to install and available with a wide range of process connections and electrical connectors.
Measures both dew point and moisture content, this dew-point transmitter has -166 to 68°F (-110 to 20°C) dp range and a standard HDPE guard for protection against fine particulates with <10 µm size. In addition, it is simple to install and available with a wide range of process connections and electrical connectors.
Moisture transmitter for safe and hazardous areas.
Features
Applications
Measurement Range | -148 to 68°F (-100 to 20°C) dew point |
Accuracy | ±3.6°F (±2°C) dew point |
Response Time | 5 mins to T95 (dry to wet) |
Repeatability | 0.9°F (0.5°C) dew point |
Calibration | Traceable 13-point calibration certificate |
Output Signal | 4 to 20 mA (2-wire connection, current source); User configurable over range |
Supply Voltage | 12 to 28 V DC |
Temperature | Operating: -40 to 140°F (-40 to 60°C) Compensated temperature range: -4 to 122°F (-20 to 50°C) Storage: -40 to 140°F (-40 to 60°C) |
Operating Pressure | 45 MPa (450 barg/6527 psig) maximum |
Flow Rate | 1 to 5 Nl/min mounted in standard sampling block; 0 to 10 m/sec direct insertion |
Ingress Protection | IP66 in accordance with standard BS EN 60529:1992; NEMA 4 protection in accordance with standard NEMA 250–2003 |
Process Connection | ⅝"; - 18 UNF |
Housing Material | 316 stainless steel |
Dimensions | MiniDIN 43650 form C L=5.2 x Ø1.77"; (132 x Ø45 mm) (with connector cable) |
Weight | 0.33 lbs (150 g) |
Click on a category to view a selection of compatible accessories with the Michell EA34-TX Dew-Point Transmitter with ¾;"; - 16 UNF, -166 to 68°F, standard HDPE guard.
Measurement Range | -148 to 68°F (-100 to 20°C) dew point |
Accuracy | ±3.6°F (±2°C) dew point |
Response Time | 5 mins to T95 (dry to wet) |
Repeatability | 0.9°F (0.5°C) dew point |
Calibration | Traceable 13-point calibration certificate |
Output Signal | 4 to 20 mA (2-wire connection, current source); User configurable over range |
Supply Voltage | 12 to 28 V DC |
Temperature | Operating: -40 to 140°F (-40 to 60°C) Compensated temperature range: -4 to 122°F (-20 to 50°C) Storage: -40 to 140°F (-40 to 60°C) |
Operating Pressure | 45 MPa (450 barg/6527 psig) maximum |
Flow Rate | 1 to 5 Nl/min mounted in standard sampling block; 0 to 10 m/sec direct insertion |
Ingress Protection | IP66 in accordance with standard BS EN 60529:1992; NEMA 4 protection in accordance with standard NEMA 250–2003 |
Process Connection | ⅝"; - 18 UNF |
Housing Material | 316 stainless steel |
Dimensions | MiniDIN 43650 form C L=5.2 x Ø1.77"; (132 x Ø45 mm) (with connector cable) |
Weight | 0.33 lbs (150 g) |