Highly intuitive and advanced, this three-phase analyzer with three 10.6" flex CTs lets you view RMS data, waveforms, demand data, phase angles, harmonics, unbalance, and flicker in real-time. This kit comes with an analyzer, voltage leads, an SD card, a USB cable, an ethernet cable, universal power cords, and 3 x CTs.
Highly intuitive and advanced, this three-phase analyzer with three 10.6" flex CTs lets you view RMS data, waveforms, demand data, phase angles, harmonics, unbalance, and flicker in real-time. This kit comes with an analyzer, voltage leads, an SD card, a USB cable, an ethernet cable, universal power cords, and 3 x CTs.
Ideal for testing power quality in any environment, this kit includes rugged and weatherproof hardware and the ability to power off Phase A or auxiliary power. Errors are minimized, making your testing more efficient with industry-leading software that enables you to analyze your results quickly and easily.
When data recording is needed, the record verification automatically identifies the current clamps, recognizes their range, and verifies that the unit is connected. In addition, this analyzer can record for extended periods because of its massive memory, utilizing an SD card which makes expanding the memory as easy as installing a new SD card. You can access the recorded data on the unit's color VGA display and transfer data to the high-power PQ Power Quality Analysis software via USB cable, USB stick, Ethernet, or the SD card.
The free software, which requires no license, optimizes this analyzer to locate the power quality phenomenon such as lighting issues, computer problems, tripping breakers, etc.
Features
Applications
Input Power | Phase A 90-600V 50/60 Hz or 105-600 V DC Aux input power - 120/240 V, 50/60 Hz Water-tight cord to operate off standard US, UK and EU plugs Supports live connect/disconnect |
Battery | NiMH battery pack (field replaceable) Discharge time: 8 hours Recharge time: 3 hours |
Data Storage | External SD card (up to 32 GB) |
Communication | Ethernet communications: network communications. Wireless communications with off-the-shelf bridge. USB stick - transfer data file to USB. Transfer setup configurations to and from USB stick. Perform firmware upgrades using USB stick. SD card: automatically writes data to SD card; no manual transfer required. Transfer setup configurations to and from SD card. No tool needed to access the SD card. |
Environmental | Operating: -4°F to 122°F (-20°C to 50°C) Storage: -22°F to 140°F (-30°C to 60°C) Relative humidity: 0 to 95% non-condensing Altitude 6561.68' (<2000 m): 1000V CAT III/600 V CAT IV Altitude 6561.68 to 13,123.36' (2000 to 4000 m): 600 V CAT III/300 V CAT IV Altitude 13,123.36 to 16,404.2' (4000 to 5000 m): 300 V CAT III/150 V CAT IV |
Case | Ruggedized enclosure IP54 when closed Lockable by means of padlock |
Display | Backlit 4.53 x 3.35" (11.5 x 8.5 cm) color VGA |
PQ Events | Dips/sags: Triggers off of voltage and current IEC61000-4-30 compliant Swells: Triggers off of voltage and current. IEC61000-4-30 compliant Sub-cycle distortions: Triggers off of voltage and current IEC61000-4-30 compliant Transient detection: 1 μsecond triggers off of first 3 voltage channels IEC61000-4-30 compliant THD: Triggers off of voltage and current IEC61000-4-30 compliant Rapid voltage change (RVC): Triggers off of first 3 voltage channels IEC61000-4-30 compliant Phase shifts: Trigger event when a phase shift occurs between the voltage channels. Record date and time, duration and waveforms of all enabled channels. Phase shift user selectable down to 1° Waveform capture of events: Capture waveforms on all enabled channels when an out of limits event occurs. Waveforms programmable with up to 9 pre-trigger cycles and 3600 post-trigger cycles Timed waveform capture: Captures waveforms periodically on all enabled channels. Waveform capture interval programmable down to 1 cycle. Programmable number of cycles to be captured up to 200 cycles Event triggered waveforms and timed triggered waveforms simultaneously Mains signaling events: Two selectable frequencies and amplitudes Selectable time interval. Measured per IEC61000-4-30 Captures waveforms on all enabled channels when a mains signaling event occurs. Waveform programmable with up to 9 pre-trigger cycles and 99 post-trigger cycles. Event flagging: Measured per IEC61000-4-30 |
Motor Inrush | Can record RMS, power, energy and PF every 1 cycle simultaneously continuously Can capture up to 1 minute of raw waveform data on every motor start up on all channels simultaneously Can monitor a motor for weeks of months continuously Support both three-phase and single-phase motors |
Real Time Data | Scope mode: View waveforms in scope mode Freeze, zoom and pan View vector scope View ANSI unbalance View IEC unbalance View harmonic in real time View inter-harmonics in real time View RMS voltage and current in real time DMM mode: View IEC unbalance View harmonic in real time View RMS voltage and current in real time View THD in real time View active power in real time View reactive power in real time View apparent power in real time View DPF in real time View TPF in real time View flicker in real time |
Compliance | IEC61000-4-7 IEC61000-4-30 Ed. 3 (Class A) IEC61000-4-15 IEC61000-4-27 IEC61010-1 RoHS2 Directive 2011/65/EU IEC6132 IEC60529 MIL-STD-810 G IEEE 1453 IEEE 1459 CAN/CSA-C22 No. 1010.1-92 |
Sampling | Resolution: 16-bit analog to digital converter on 8 channels Maximum speed: 1 MHz Maximum RMS: 17,664 per channel PLL synchronization: 42.5 to 69 Hz |
Real Time Clock | Accuracy: ±20 ppm |
Voltage | AC voltage range: 0 to 1000 V AC RMS DC voltage range: ±1500 V DC AC voltage accuracy: 0.1% per IEC61000-4-30 DC voltage accuracy: ±0.2% of full scale ±2 V DC Voltage ratios: Adjustable voltage ratios for measuring secondaries (0.0001 through 9999) Resolution: 16 bit Crest factor: 1.5 Maximum pk voltage: 1628 V/2500 V Impedance: 20.01 MΩ to gnd nominal Voltage lead set: 4 voltage leads, 6' (2 m) in length, safety banana leads, removable alligator clips, set of color bands for customizing color codes, safety green/yellow ground lead |
Current Channels | 5 current channels Range: 0 to 6000 A (CT dependent) Ratios: Adjustable current ratios for measuring secondaries (000.1 through 9999) AC accuracy: ±0.5% of reading ±0.05% of full scale DC accuracy: ±1.0% of full scale Resolution: 16 bit Crest factor: 4.0 |
Power and Energy | Active power (KW): Per IEEE1459 Reactive power (KVAR): Per IEEE1459 Apparent power (KVA): Per IEEE1459 Energy parameters (KWH, KVARH, KVAH): Per IEEE1459 Displacement power factor range: -1 to 1 Displacement power factor accuracy: ±0.02 + CT error True power factor range: 0 to 1 True power factor accuracy: ±0.02 + CT error Power configurations: 11 Aggregation window: 1 cycle to 1 hour - fixed and sliding windows Unbalance: ANSI and IEC methodology per IEC61000-4-27 Total harmonic distortion (THD): Per IEC61000-4-30 & IEC 61000-4-7 Distortion 200ms, 3 seconds, 10 minutes windows Vthd 0 to 100%, ±5% for V≥1% Vnom, Ithd ±5% reading at ≥3% Inom, ±0.15% full scale at <3% Inom Harmonics: 0 through 50th continuous Inter-harmonics: 0 through 50th continuous Total demand distortion (TDD): Per IEEE519 Frequency: Per IEC61000-4-30 Flicker: Per IEC61000-4-15 Pst: 10 minutes: 0.2-10, ±0.05 at Pst=1 (50/60 Hz only) Plt: 2 hours: 0.2-10, ±0.05 at Pst=1 (50/60 Hz only) |
Functions | Auto identify CT and CT range setting Configuration verification - Display if unit is connected incorrectly On board analysis - Perform data analysis on unit. Compare recorded values against customizable templates Waveform analysis through the 128th order Clock hour orientation - Time sync recording to nearest interval Scheduled run - Select start and stop time of recording. Instrument then automatically begins recording On board configuration - Ability to configure recording parameters from front panel of instrument Auto setup - Ability to have instrument automatically configure itself On board naming of data and setup files -Ability to name data and setup files from the front panel of the instrument Supported languages: English, Spanish, French, German and Czech On board instrument preference settings: Selectable traces colors Selectable short cut buttons Selectable time out period Chart grid ON/OFF |
Measurement Parameters | RMS voltage RMS current Sags/dips/swells Transients (1 msecond) (±2697 V) Sub-cycle events 64 msecond (notching, noise) Rapid voltage change Phase angle stability IEC unbalance ANSII unbalance Power (KW, KVAR, KVA, DPF and TPF) Energy (KWH, KVARH and KVAH) Power factor 1 to 0 to -1 Phase angle THD TDD Harmonics Inter-harmonics Power harmonics Harmonic direction Flicker Waveform capture Frequency |
Software | Windows compliant (XP, Win 7, 8, 10) |
Click on a category to view a selection of compatible accessories with the Megger MPQ2000 Power Quality Analyzer Gold Kit with three 10.6" flex CT's, 1000 V AC, 1500 V DC.
Input Power | Phase A 90-600V 50/60 Hz or 105-600 V DC Aux input power - 120/240 V, 50/60 Hz Water-tight cord to operate off standard US, UK and EU plugs Supports live connect/disconnect |
Battery | NiMH battery pack (field replaceable) Discharge time: 8 hours Recharge time: 3 hours |
Data Storage | External SD card (up to 32 GB) |
Communication | Ethernet communications: network communications. Wireless communications with off-the-shelf bridge. USB stick - transfer data file to USB. Transfer setup configurations to and from USB stick. Perform firmware upgrades using USB stick. SD card: automatically writes data to SD card; no manual transfer required. Transfer setup configurations to and from SD card. No tool needed to access the SD card. |
Environmental | Operating: -4°F to 122°F (-20°C to 50°C) Storage: -22°F to 140°F (-30°C to 60°C) Relative humidity: 0 to 95% non-condensing Altitude 6561.68' (<2000 m): 1000V CAT III/600 V CAT IV Altitude 6561.68 to 13,123.36' (2000 to 4000 m): 600 V CAT III/300 V CAT IV Altitude 13,123.36 to 16,404.2' (4000 to 5000 m): 300 V CAT III/150 V CAT IV |
Case | Ruggedized enclosure IP54 when closed Lockable by means of padlock |
Display | Backlit 4.53 x 3.35" (11.5 x 8.5 cm) color VGA |
PQ Events | Dips/sags: Triggers off of voltage and current IEC61000-4-30 compliant Swells: Triggers off of voltage and current. IEC61000-4-30 compliant Sub-cycle distortions: Triggers off of voltage and current IEC61000-4-30 compliant Transient detection: 1 μsecond triggers off of first 3 voltage channels IEC61000-4-30 compliant THD: Triggers off of voltage and current IEC61000-4-30 compliant Rapid voltage change (RVC): Triggers off of first 3 voltage channels IEC61000-4-30 compliant Phase shifts: Trigger event when a phase shift occurs between the voltage channels. Record date and time, duration and waveforms of all enabled channels. Phase shift user selectable down to 1° Waveform capture of events: Capture waveforms on all enabled channels when an out of limits event occurs. Waveforms programmable with up to 9 pre-trigger cycles and 3600 post-trigger cycles Timed waveform capture: Captures waveforms periodically on all enabled channels. Waveform capture interval programmable down to 1 cycle. Programmable number of cycles to be captured up to 200 cycles Event triggered waveforms and timed triggered waveforms simultaneously Mains signaling events: Two selectable frequencies and amplitudes Selectable time interval. Measured per IEC61000-4-30 Captures waveforms on all enabled channels when a mains signaling event occurs. Waveform programmable with up to 9 pre-trigger cycles and 99 post-trigger cycles. Event flagging: Measured per IEC61000-4-30 |
Motor Inrush | Can record RMS, power, energy and PF every 1 cycle simultaneously continuously Can capture up to 1 minute of raw waveform data on every motor start up on all channels simultaneously Can monitor a motor for weeks of months continuously Support both three-phase and single-phase motors |
Real Time Data | Scope mode: View waveforms in scope mode Freeze, zoom and pan View vector scope View ANSI unbalance View IEC unbalance View harmonic in real time View inter-harmonics in real time View RMS voltage and current in real time DMM mode: View IEC unbalance View harmonic in real time View RMS voltage and current in real time View THD in real time View active power in real time View reactive power in real time View apparent power in real time View DPF in real time View TPF in real time View flicker in real time |
Compliance | IEC61000-4-7 IEC61000-4-30 Ed. 3 (Class A) IEC61000-4-15 IEC61000-4-27 IEC61010-1 RoHS2 Directive 2011/65/EU IEC6132 IEC60529 MIL-STD-810 G IEEE 1453 IEEE 1459 CAN/CSA-C22 No. 1010.1-92 |
Sampling | Resolution: 16-bit analog to digital converter on 8 channels Maximum speed: 1 MHz Maximum RMS: 17,664 per channel PLL synchronization: 42.5 to 69 Hz |
Real Time Clock | Accuracy: ±20 ppm |
Voltage | AC voltage range: 0 to 1000 V AC RMS DC voltage range: ±1500 V DC AC voltage accuracy: 0.1% per IEC61000-4-30 DC voltage accuracy: ±0.2% of full scale ±2 V DC Voltage ratios: Adjustable voltage ratios for measuring secondaries (0.0001 through 9999) Resolution: 16 bit Crest factor: 1.5 Maximum pk voltage: 1628 V/2500 V Impedance: 20.01 MΩ to gnd nominal Voltage lead set: 4 voltage leads, 6' (2 m) in length, safety banana leads, removable alligator clips, set of color bands for customizing color codes, safety green/yellow ground lead |
Current Channels | 5 current channels Range: 0 to 6000 A (CT dependent) Ratios: Adjustable current ratios for measuring secondaries (000.1 through 9999) AC accuracy: ±0.5% of reading ±0.05% of full scale DC accuracy: ±1.0% of full scale Resolution: 16 bit Crest factor: 4.0 |
Power and Energy | Active power (KW): Per IEEE1459 Reactive power (KVAR): Per IEEE1459 Apparent power (KVA): Per IEEE1459 Energy parameters (KWH, KVARH, KVAH): Per IEEE1459 Displacement power factor range: -1 to 1 Displacement power factor accuracy: ±0.02 + CT error True power factor range: 0 to 1 True power factor accuracy: ±0.02 + CT error Power configurations: 11 Aggregation window: 1 cycle to 1 hour - fixed and sliding windows Unbalance: ANSI and IEC methodology per IEC61000-4-27 Total harmonic distortion (THD): Per IEC61000-4-30 & IEC 61000-4-7 Distortion 200ms, 3 seconds, 10 minutes windows Vthd 0 to 100%, ±5% for V≥1% Vnom, Ithd ±5% reading at ≥3% Inom, ±0.15% full scale at <3% Inom Harmonics: 0 through 50th continuous Inter-harmonics: 0 through 50th continuous Total demand distortion (TDD): Per IEEE519 Frequency: Per IEC61000-4-30 Flicker: Per IEC61000-4-15 Pst: 10 minutes: 0.2-10, ±0.05 at Pst=1 (50/60 Hz only) Plt: 2 hours: 0.2-10, ±0.05 at Pst=1 (50/60 Hz only) |
Functions | Auto identify CT and CT range setting Configuration verification - Display if unit is connected incorrectly On board analysis - Perform data analysis on unit. Compare recorded values against customizable templates Waveform analysis through the 128th order Clock hour orientation - Time sync recording to nearest interval Scheduled run - Select start and stop time of recording. Instrument then automatically begins recording On board configuration - Ability to configure recording parameters from front panel of instrument Auto setup - Ability to have instrument automatically configure itself On board naming of data and setup files -Ability to name data and setup files from the front panel of the instrument Supported languages: English, Spanish, French, German and Czech On board instrument preference settings: Selectable traces colors Selectable short cut buttons Selectable time out period Chart grid ON/OFF |
Measurement Parameters | RMS voltage RMS current Sags/dips/swells Transients (1 msecond) (±2697 V) Sub-cycle events 64 msecond (notching, noise) Rapid voltage change Phase angle stability IEC unbalance ANSII unbalance Power (KW, KVAR, KVA, DPF and TPF) Energy (KWH, KVARH and KVAH) Power factor 1 to 0 to -1 Phase angle THD TDD Harmonics Inter-harmonics Power harmonics Harmonic direction Flicker Waveform capture Frequency |
Software | Windows compliant (XP, Win 7, 8, 10) |
Click on a category to view a selection of compatible accessories with the Megger MPQ2000 Power Quality Analyzer Gold Kit with three 10.6" flex CT's, 1000 V AC, 1500 V DC.