This meter adds additional features required for engineers working on more demanding applications. Functions such as PI and DAR, capacitance measurement and a greater range of test voltages increase the suitability for many applications. The stabilized insulation test voltage is accurate to +2% -0%. This compares to the industry standard +20%, providing a more accurate test voltage without risking over-voltage damage to circuits or components. The output voltage is consistant between 0 and 2% throughout the test range. This value added kit includes the R9999 Industrial Tool Bag for FREE.
This meter adds additional features required for engineers working on more demanding applications. Functions such as PI and DAR, capacitance measurement and a greater range of test voltages increase the suitability for many applications. The stabilized insulation test voltage is accurate to +2% -0%. This compares to the industry standard +20%, providing a more accurate test voltage without risking over-voltage damage to circuits or components. The output voltage is consistant between 0 and 2% throughout the test range. This value added kit includes the R9999 Industrial Tool Bag for FREE.
This insulation tester features a variable range to allow any intermediate voltage from 10 V to 1000 V in 1 V steps, when testing specific test voltages that do not appear in the standard ranges is required. Continuity testing is now significantly faster, and a single auto-ranging 0.01 Ω to 1.0 MΩ function replaces the "ohms" and "kOhms" ranges. Retained are the 200 mA and 20 mA test options. The instrument is over-moulded for increased protection and has an IP54 weatherproof rating.
Features
Black and blue polyester bag with a reinforced bottom, padded shoulder strap, double zipper and mesh pockets. Outside Dimensions (LxWxH): 15.8 x 7.8 x 11.8" (400 x 200 x 300mm).
Applications
Test voltage | 50 V, 100 V, 250 V, 500 V, 1000 V |
Display range | Analogue: 1 GΩ full scale |
Resolution | 0.1 kΩ |
Short circuit/charge current | 2 mA +0% -50% to EN 61557-2 (2007) |
Open circuit voltage insulation | -0% +2% ± 2V |
Test current | 1 mA at min. pass value of insulation to a maximum of 2 mA max. |
Leakage | 10% ±3 digits |
Voltage | 3% ±3 digits ±0.5% of rated voltage |
Timer control | 60 second countdown timer |
Continuity measurement | 0.01 Ω to 999 kΩ (0 to 1000 kΩ on analogue scale) |
Open circuit voltage | 5 V ± 1 V |
Test current | 200 mA (–0 mA +20 mA), (0.01 Ω to 4 Ω) |
Polarity | Single polarity (Default) / Dual polarity (configurable on setup). |
Lead resistance | Null up to 9.00 Ω |
Voltage range | AC: 10 mV to 600 V TRMS sinusoidal (15 Hz to 400 Hz) DC: 0 to 600 V |
Frequency measurement range | 15 Hz - 400 Hz |
Frequency measurement accuracy | ±0.5% ± 1digit (100 Hz to 400 Hz unspecified) |
Storage capacity | >1000 test results |
Data download | Bluetooth® wireless, Bluetooth® Class II |
Power supply | 6 x 1.5 V cells type IEC LR6 (AA, MN1500, HP7, AM3 R6HP) Alkaline 6 x 1.2 V NiMH rechargeable cells may be used |
Battery life | 3000 insulation tests with duty cycle of 5 sec ON /55 sec OFF @ 1000 V into 1 MΩ |
The stabilized insulation test voltage is accurate to +2% -0%. This compares to the industry standard +20%, providing a more accurate test voltage without risking over-voltage damage to circuits or components. The output voltage is consistant between 0 and 2% throughout the test range.
Case is black and blue polyester with plastic injection logo. Outside Dimensions (LxWxH): 15.8 x 7.8 x 11.8" (400 x 200 x 300mm).
Test voltage | 50 V, 100 V, 250 V, 500 V, 1000 V |
Display range | Analogue: 1 GΩ full scale |
Resolution | 0.1 kΩ |
Short circuit/charge current | 2 mA +0% -50% to EN 61557-2 (2007) |
Open circuit voltage insulation | -0% +2% ± 2V |
Test current | 1 mA at min. pass value of insulation to a maximum of 2 mA max. |
Leakage | 10% ±3 digits |
Voltage | 3% ±3 digits ±0.5% of rated voltage |
Timer control | 60 second countdown timer |
Continuity measurement | 0.01 Ω to 999 kΩ (0 to 1000 kΩ on analogue scale) |
Open circuit voltage | 5 V ± 1 V |
Test current | 200 mA (–0 mA +20 mA), (0.01 Ω to 4 Ω) |
Polarity | Single polarity (Default) / Dual polarity (configurable on setup). |
Lead resistance | Null up to 9.00 Ω |
Voltage range | AC: 10 mV to 600 V TRMS sinusoidal (15 Hz to 400 Hz) DC: 0 to 600 V |
Frequency measurement range | 15 Hz - 400 Hz |
Frequency measurement accuracy | ±0.5% ± 1digit (100 Hz to 400 Hz unspecified) |
Storage capacity | >1000 test results |
Data download | Bluetooth® wireless, Bluetooth® Class II |
Power supply | 6 x 1.5 V cells type IEC LR6 (AA, MN1500, HP7, AM3 R6HP) Alkaline 6 x 1.2 V NiMH rechargeable cells may be used |
Battery life | 3000 insulation tests with duty cycle of 5 sec ON /55 sec OFF @ 1000 V into 1 MΩ |
The stabilized insulation test voltage is accurate to +2% -0%. This compares to the industry standard +20%, providing a more accurate test voltage without risking over-voltage damage to circuits or components. The output voltage is consistant between 0 and 2% throughout the test range.