MadgeTech VFC2000 without Glycol Bottle Specifications

Specifications
Memory 16,128 readings (all channels enabled)
Reading Rate 1 reading every second up to 1 reading every 24 hours
Cold Junction Compensation Automatic based on internal channel
Battery Life 3 years typical at 1 minute reading rate
Material ABS Plastic
Dimensions 3.0 x 3.5 x 0.95" (76.2 x 88.9 x 24.1 mm) - Data logger only
Operating Environment -4 to +140°F (-20 to +60°C), 0% RH to 95% RH non-condensing
Required Interface Package USB to Mini USB Cable
Weight 1.1250 lbs
Baud Rate 250,000
Internal Channel Temperature Sensor Semiconductor
Internal Channel Temperature Range -4 to +140°F (-20 to 60°C)
Internal Channel Temperature Resolution 0.18°F (0.01°C)
Internal Channel Temperature Calibrated Accuracy ±0.5°C (0 to +50°C)
Remote Channel Temperature Sensor Type K Thermocouple (Included)
Remote Channel (Thermocouple) Temperature Range -148 to +176°F (-100 to +80°C)
Remote Channel (Glycol Bottle) Temperature Range -58 to +176°F (-50 to +80°C)
Remote Channel Temperature Resolution 0.18°F (0.1°C)
Remote Channel Temperature Calibrated Accuracy ±0.5°C
Click here for complete specifications on the MadgeTech VFC2000 without Glycol Bottle

What's included with the MadgeTech VFC2000 without Glycol Bottle

  • MadgeTech VFC2000 without Glycol Bottle Vaccine Temperature Monitoring System

Ask a question about MadgeTech VFC2000 without Glycol Bottle Vaccine Temperature Monitoring System

Customer Reviews for the MadgeTech VFC2000 without Glycol Bottle

MadgeTech VFC2000 without Glycol Bottle Specifications

Specifications
Memory 16,128 readings (all channels enabled)
Reading Rate 1 reading every second up to 1 reading every 24 hours
Cold Junction Compensation Automatic based on internal channel
Battery Life 3 years typical at 1 minute reading rate
Material ABS Plastic
Dimensions 3.0 x 3.5 x 0.95" (76.2 x 88.9 x 24.1 mm) - Data logger only
Operating Environment -4 to +140°F (-20 to +60°C), 0% RH to 95% RH non-condensing
Required Interface Package USB to Mini USB Cable
Weight 1.1250 lbs
Baud Rate 250,000
Internal Channel Temperature Sensor Semiconductor
Internal Channel Temperature Range -4 to +140°F (-20 to 60°C)
Internal Channel Temperature Resolution 0.18°F (0.01°C)
Internal Channel Temperature Calibrated Accuracy ±0.5°C (0 to +50°C)
Remote Channel Temperature Sensor Type K Thermocouple (Included)
Remote Channel (Thermocouple) Temperature Range -148 to +176°F (-100 to +80°C)
Remote Channel (Glycol Bottle) Temperature Range -58 to +176°F (-50 to +80°C)
Remote Channel Temperature Resolution 0.18°F (0.1°C)
Remote Channel Temperature Calibrated Accuracy ±0.5°C
Click here for complete specifications on the MadgeTech VFC2000 without Glycol Bottle

What's included with the MadgeTech VFC2000 without Glycol Bottle

  • MadgeTech VFC2000 without Glycol Bottle Vaccine Temperature Monitoring System

Ask a question about MadgeTech VFC2000 without Glycol Bottle Vaccine Temperature Monitoring System

Customer Reviews for the MadgeTech VFC2000 without Glycol Bottle

More MadgeTech Products