Handheld Wet Bulb Globe Temperature measurement tool and data logger that detects when heat-related conditions are unsafe well before your body does. This instrument is also a full weather meter that measures up to 15 parameters in all.
Handheld Wet Bulb Globe Temperature measurement tool and data logger that detects when heat-related conditions are unsafe well before your body does. This instrument is also a full weather meter that measures up to 15 parameters in all.
No matter what your activity, the Kestrel 5400 series heat stress tracker provides insight into the critical conditions affecting safety, performance and success. Getting accurate heat related measurements to keep your athletes and workers safe couldn't be easier. This meter provides instant notification of dangerous conditions on the bright LED beacon and on-screen warning system.
Improved tripod mount, waterproof data transfer cable make the Kestrel 5 Series the most user friendly innovative line ever.
Features
Applications
Every Kestrel 5 Series meter is drop-tested, waterproof, dustproof and just as rugged, reliable and dependable.
Sensors | |
Wind Speed/Air Speed | Accuracy: Larger of 3% of reading, least significant digit or 20ft/min Resolution: 0.1 m/s, 1 ft/min, 0.1 km/h, 0.1 mph, 0.1 knots, 1 B, 0.1 F/S Specification range: 0.6 to 40.0 m/s, 118 to 7,874 ft/min, 2.2 to 144.0 km/h, 1.3 to 89.5 mph, 1.2 to 77.8 knots, 0 to 12 B, 2-131.2 |
Ambient Temperature | Accuracy: 0.9°F (0.5°C) Resolution: 0.1°F (0.1°C) Specification range: -20 to 158°F (29 to 70°C) |
Globe Temperature | Accuracy: 2.5°F (1.4°C) Resolution: 0.1°F (0.1°C) Specification range: -20 to 140°F (29 to 60°C) |
Relative Humidity | Accuracy: 2% RH Resolution: 0.1% RH Specification range: 10 to 90% 25°C noncondensing |
Pressure | 1.5 hPa|mbar, 0.044 inHg, 0.022 PSI Resolution: 0.1 hPa|mbar, 0.01 inHg, 0.01 PSI Specification range: 77°F (25°C), 700-1100 hPa|mbar, 20.67 to 32.48 inHg, 10.15 to 15.95 PSI |
Compass | Accuracy: 5° Resolution: 1°, 1/16th Cardinal Scale Specification range: 0 to 360° |
Calculated Measurements | |
AHLU | Accuracy: AHLU Accuracy derived, from HLI accuracy, accumulated over time. Resolution: 1.0 Sensors employed: Wind Speed, Temperature, Globe Temperature, Relative Humidity |
Altitude | Accuracy: typical: 23.6 ft/7.2 m from 750 to 1100 mBar, max: 48.2 ft/14.7 m from 300 to 750 mBar Resolution: 1 ft/1 m Sensors employed: Pressure, User Input (Reference Pressure) |
Barometric Pressure | Accuracy: 0.07 inHg, 2.4 hPa|mbar, 0.03 PSI Resolution: 0.01 inHg, 0.1 hPa|mbar, 0.01 PSI Sensors employed: Pressure, User Input, (Reference Altitude) |
Sometimes we only use the air temperature as a measure of how comfortable we will feel when working or playing outside. But when the days get longer and the sun becomes stronger we need to take into account a lot more than air temperature.
Heat-induced illnesses, such as heat exhaustion and heat stroke occur when your body can't keep itself cool. The evaporation of sweat is slowed on hot and humid days causing your body temperature to rise and become ill.
Symptoms of Heat Exhaustion and Heat Stroke
Preventing Heat Stress
And most importantly….Monitor the conditions you are in with a Heat Stress Meter
These meters measure how hot it REALLY feels outside when humidity is combined with temperature, air movement and radiant heat.
What is WBGT or Wet Bulb Globe Temperature?
WBGT index is a term used in industry, sports and other areas to indicate the heat stress level for humans and animals. It calculates the heat stress of radiant heat, which takes into account temperature, humidity, wind speed, sun angle and cloud cover. This type of meter combines these factors into a single number so you can quickly take into account the conditions you are in.
What is Black Globe Temperature (GT)?
Skin can burn when it comes in contact with exposed machinery, tools and containers left in hot direct sunlight. Black Globe Temperature represents the integrated effects of radiation and wind on these objects.
Click on a category to view a selection of compatible accessories with the Kestrel 5400 Heat Stress Tracker, Tan.
Sensors | |
Wind Speed/Air Speed | Accuracy: Larger of 3% of reading, least significant digit or 20ft/min Resolution: 0.1 m/s, 1 ft/min, 0.1 km/h, 0.1 mph, 0.1 knots, 1 B, 0.1 F/S Specification range: 0.6 to 40.0 m/s, 118 to 7,874 ft/min, 2.2 to 144.0 km/h, 1.3 to 89.5 mph, 1.2 to 77.8 knots, 0 to 12 B, 2-131.2 |
Ambient Temperature | Accuracy: 0.9°F (0.5°C) Resolution: 0.1°F (0.1°C) Specification range: -20 to 158°F (29 to 70°C) |
Globe Temperature | Accuracy: 2.5°F (1.4°C) Resolution: 0.1°F (0.1°C) Specification range: -20 to 140°F (29 to 60°C) |
Relative Humidity | Accuracy: 2% RH Resolution: 0.1% RH Specification range: 10 to 90% 25°C noncondensing |
Pressure | 1.5 hPa|mbar, 0.044 inHg, 0.022 PSI Resolution: 0.1 hPa|mbar, 0.01 inHg, 0.01 PSI Specification range: 77°F (25°C), 700-1100 hPa|mbar, 20.67 to 32.48 inHg, 10.15 to 15.95 PSI |
Compass | Accuracy: 5° Resolution: 1°, 1/16th Cardinal Scale Specification range: 0 to 360° |
Calculated Measurements | |
AHLU | Accuracy: AHLU Accuracy derived, from HLI accuracy, accumulated over time. Resolution: 1.0 Sensors employed: Wind Speed, Temperature, Globe Temperature, Relative Humidity |
Altitude | Accuracy: typical: 23.6 ft/7.2 m from 750 to 1100 mBar, max: 48.2 ft/14.7 m from 300 to 750 mBar Resolution: 1 ft/1 m Sensors employed: Pressure, User Input (Reference Pressure) |
Barometric Pressure | Accuracy: 0.07 inHg, 2.4 hPa|mbar, 0.03 PSI Resolution: 0.01 inHg, 0.1 hPa|mbar, 0.01 PSI Sensors employed: Pressure, User Input, (Reference Altitude) |
Sometimes we only use the air temperature as a measure of how comfortable we will feel when working or playing outside. But when the days get longer and the sun becomes stronger we need to take into account a lot more than air temperature.
Heat-induced illnesses, such as heat exhaustion and heat stroke occur when your body can't keep itself cool. The evaporation of sweat is slowed on hot and humid days causing your body temperature to rise and become ill.
Symptoms of Heat Exhaustion and Heat Stroke
Preventing Heat Stress
And most importantly….Monitor the conditions you are in with a Heat Stress Meter
These meters measure how hot it REALLY feels outside when humidity is combined with temperature, air movement and radiant heat.
What is WBGT or Wet Bulb Globe Temperature?
WBGT index is a term used in industry, sports and other areas to indicate the heat stress level for humans and animals. It calculates the heat stress of radiant heat, which takes into account temperature, humidity, wind speed, sun angle and cloud cover. This type of meter combines these factors into a single number so you can quickly take into account the conditions you are in.
What is Black Globe Temperature (GT)?
Skin can burn when it comes in contact with exposed machinery, tools and containers left in hot direct sunlight. Black Globe Temperature represents the integrated effects of radiation and wind on these objects.
Click on a category to view a selection of compatible accessories with the Kestrel 5400 Heat Stress Tracker, Tan.