This full featured weather/heat stress meter allows you to detect when heat-related conditions are unsafe. This meter measures up to 15 parameters and features LINK that provides wireless communication to mobile devices and computers.
This full featured weather/heat stress meter allows you to detect when heat-related conditions are unsafe. This meter measures up to 15 parameters and features LINK that provides wireless communication to mobile devices and computers.
This all-inclusive heat stress tracker meter has many different features to detect hazardous conditions before situations get dangerous for anyone outside. It provides instant notification of dangerous conditions with a loud buzzer, bright LED beacon and on-screen warnings. The vane mount provides hands-free measurements over the course of the practice, training session or workday.
The Kestrel 5400 with LiNK wireless data communication adds a compass for tracking wind direction as well, expanding its usability to include HAZMAT response, and even measuring headwind at the running track!
LINK is a simple communication to Windows and Mac computers is provided through the optional LiNK .USB Dongle or USB Data Transfer Cable. Download your data to view, analyze and archive. Enables firmware update of Kestrel 5 series meters. LINK for iOS and Android (coming soon) Wirelessly connect with iOS and Android devices. When in range, view real-time measurements, receive on-screen alerts and download your data. Logged data can be viewed, analyzed, archived and shared via e-mail, Facebook and Twitter. Enables firmware update of Kestrel 5 series meters. NOTE: Range up to 100' line of sight – reduced by walls and obstructions.
Improved tripod mount, waterproof data transfer cable make the Kestrel 5 Series the most user friendly innovative line ever.
Features
Applications
Every Kestrel 5 Series meter is drop-tested, waterproof, dustproof and rugged, reliable and dependable.
Sensors | |
Wind Speed/Air Speed | Accuracy: Larger of 3% of reading, least significant digit or 20ft/min Resolution: 0.1 m/s, 1 ft/min, 0.1 km/h, 0.1 mph, 0.1 knots, 1 B, 0.1 F/S Specification range: 0.6 to 40.0 m/s, 118 to 7,874 ft/min, 2.2 to 144.0 km/h, 1.3 to 89.5 mph, 1.2 to 77.8 knots, 0 to 12 B, 2-131.2 |
Ambient Temperature | Accuracy: 0.9°F (0.5°C) Resolution: 0.1°F (0.1°C) Specification range: -20 to 158°F (29 to 70°C) |
Globe Temperature | Accuracy: 2.5°F (1.4°C) Resolution: 0.1°F (0.1°C) Specification range: -20 to 140°F (29 to 60°C) |
Relative Humidity | Accuracy: 2% RH Resolution: 0.1% RH Specification range: 10 to 90% 25°C noncondensing |
Pressure | 1.5 hPa|mbar, 0.044 inHg, 0.022 PSI Resolution: 0.1 hPa|mbar, 0.01 inHg, 0.01 PSI Specification range: 77°F (25°C), 700-1100 hPa|mbar, 20.67 to 32.48 inHg, 10.15 to 15.95 PSI |
Compass | Accuracy: 5° Resolution: 1°, 1/16th Cardinal Scale Specification range: 0 to 360° |
Calculated Measurements | |
AHLU | Accuracy: AHLU Accuracy derived, from HLI accuracy, accumulated over time. Resolution: 1.0 Sensors employed: Wind Speed, Temperature, Globe Temperature, Relative Humidity |
Altitude | Accuracy: typical: 23.6 ft/7.2 m from 750 to 1100 mBar, max: 48.2 ft/14.7 m from 300 to 750 mBar Resolution: 1 ft/1 m Sensors employed: Pressure, User Input (Reference Pressure) |
Barometric Pressure | Accuracy: 0.07 inHg, 2.4 hPa|mbar, 0.03 PSI Resolution: 0.01 inHg, 0.1 hPa|mbar, 0.01 PSI Sensors employed: Pressure, User Input, (Reference Altitude) |
Sometimes we only use the air temperature as a measure of how comfortable we will feel when working or playing outside. But when the days get longer and the sun becomes stronger we need to take into account a lot more than air temperature.
Heat-induced illnesses, such as heat exhaustion and heat stroke occur when your body can't keep itself cool. The evaporation of sweat is slowed on hot and humid days causing your body temperature to rise and become ill.
Symptoms of Heat Exhaustion and Heat Stroke
Preventing Heat Stress
And most importantly….Monitor the conditions you are in with a Heat Stress Meter
These meters measure how hot it REALLY feels outside when humidity is combined with temperature, air movement and radiant heat.
What is WBGT or Wet Bulb Globe Temperature?
WBGT index is a term used in industry, sports and other areas to indicate the heat stress level for humans and animals. It calculates the heat stress of radiant heat, which takes into account temperature, humidity, wind speed, sun angle and cloud cover. This type of meter combines these factors into a single number so you can quickly take into account the conditions you are in.
What is Black Globe Temperature (GT)?
Skin can burn when it comes in contact with exposed machinery, tools and containers left in hot direct sunlight. Black Globe Temperature represents the integrated effects of radiation and wind on these objects.
Click on a category to view a selection of compatible accessories with the Kestrel 5400 Heat Stress Tracker Pro with LiNK, Compass + Vane Mount.
Sensors | |
Wind Speed/Air Speed | Accuracy: Larger of 3% of reading, least significant digit or 20ft/min Resolution: 0.1 m/s, 1 ft/min, 0.1 km/h, 0.1 mph, 0.1 knots, 1 B, 0.1 F/S Specification range: 0.6 to 40.0 m/s, 118 to 7,874 ft/min, 2.2 to 144.0 km/h, 1.3 to 89.5 mph, 1.2 to 77.8 knots, 0 to 12 B, 2-131.2 |
Ambient Temperature | Accuracy: 0.9°F (0.5°C) Resolution: 0.1°F (0.1°C) Specification range: -20 to 158°F (29 to 70°C) |
Globe Temperature | Accuracy: 2.5°F (1.4°C) Resolution: 0.1°F (0.1°C) Specification range: -20 to 140°F (29 to 60°C) |
Relative Humidity | Accuracy: 2% RH Resolution: 0.1% RH Specification range: 10 to 90% 25°C noncondensing |
Pressure | 1.5 hPa|mbar, 0.044 inHg, 0.022 PSI Resolution: 0.1 hPa|mbar, 0.01 inHg, 0.01 PSI Specification range: 77°F (25°C), 700-1100 hPa|mbar, 20.67 to 32.48 inHg, 10.15 to 15.95 PSI |
Compass | Accuracy: 5° Resolution: 1°, 1/16th Cardinal Scale Specification range: 0 to 360° |
Calculated Measurements | |
AHLU | Accuracy: AHLU Accuracy derived, from HLI accuracy, accumulated over time. Resolution: 1.0 Sensors employed: Wind Speed, Temperature, Globe Temperature, Relative Humidity |
Altitude | Accuracy: typical: 23.6 ft/7.2 m from 750 to 1100 mBar, max: 48.2 ft/14.7 m from 300 to 750 mBar Resolution: 1 ft/1 m Sensors employed: Pressure, User Input (Reference Pressure) |
Barometric Pressure | Accuracy: 0.07 inHg, 2.4 hPa|mbar, 0.03 PSI Resolution: 0.01 inHg, 0.1 hPa|mbar, 0.01 PSI Sensors employed: Pressure, User Input, (Reference Altitude) |
Sometimes we only use the air temperature as a measure of how comfortable we will feel when working or playing outside. But when the days get longer and the sun becomes stronger we need to take into account a lot more than air temperature.
Heat-induced illnesses, such as heat exhaustion and heat stroke occur when your body can't keep itself cool. The evaporation of sweat is slowed on hot and humid days causing your body temperature to rise and become ill.
Symptoms of Heat Exhaustion and Heat Stroke
Preventing Heat Stress
And most importantly….Monitor the conditions you are in with a Heat Stress Meter
These meters measure how hot it REALLY feels outside when humidity is combined with temperature, air movement and radiant heat.
What is WBGT or Wet Bulb Globe Temperature?
WBGT index is a term used in industry, sports and other areas to indicate the heat stress level for humans and animals. It calculates the heat stress of radiant heat, which takes into account temperature, humidity, wind speed, sun angle and cloud cover. This type of meter combines these factors into a single number so you can quickly take into account the conditions you are in.
What is Black Globe Temperature (GT)?
Skin can burn when it comes in contact with exposed machinery, tools and containers left in hot direct sunlight. Black Globe Temperature represents the integrated effects of radiation and wind on these objects.
Click on a category to view a selection of compatible accessories with the Kestrel 5400 Heat Stress Tracker Pro with LiNK, Compass + Vane Mount.