Capable of data logging multiple parameters simultaneously including CO, CO2, temperature and relative humidity. Features built in memory capable of storing multiple point measurements.
Capable of data logging multiple parameters simultaneously including CO, CO2, temperature and relative humidity. Features built in memory capable of storing multiple point measurements.
Discontinued!
This product has been discontinued and is no longer available.
This is the direct replacement:
The Kanomax IAQ Monitor 2211 features quick start-up and high accuracy in measuring carbon dioxide and carbon monoxide concentration levels in the environment. Temperature and humidity are also simultaneously measured in ah handy lightweight design.
CO |
Range | 0 to
500PPM |
Accuracy | +/-3% of
reading or +/-3PPM whichever is
greater |
|
Resolution | 0.1PPM:
0-99PPM 1PPM: 100-500 PPM |
|
CO2 |
Range | 0 to 5000PPM |
Accuracy | +/-3% of
reading or+/-50PPM whichever is
greater |
|
Resolution | 1PPM | |
Temperature |
Range |
-
4 to 140F (-20 to 60C) |
Accuracy | +/- 1F (+/-0.5C) | |
Resolution |
0.1F
(0.1C ) |
|
Relative
Humidity |
Range | 2 to
98%RH |
Accuracy | 2 to
80%RH:±2%RH, 80 to 98%RH:±3%RH |
|
Resolution | 0.1%RH |
|
Function |
Normal
Mode |
Normal
measuring (do not store and
calculate the data.) Relative
humidity, CO, CO2, Dew point, Wet
bulb temperature, Absolute humidity
and Humidity Ratio |
Calculation
Mode |
Store
the
data, and calculate the maximum,
minimum and average value. |
|
%
OA Mode |
Measure
ventilation
ratio (Ask for ventilation ratio by
calculating from temperature and CO2
value) |
|
Data
Output
Mode |
Perform
re-calculation
of stored data and output of data to
PC and Printer. |
|
Calibration
Mode |
Perform
the
calibration of CO and CO2. |
|
Output |
Digital |
RS232C |
Analog
(option) |
DC 0 to 1V |
|
Power Supply | AAA Battery x 4 (Mn, Alkaline, or Ni-Cd) | |
Dimensions |
Unit |
3.5" x
7.5" x 2.0" |
Probe |
Length:
12.5 inch / Diameter: 1.0 inch |
|
Weight (including batteries) | Approx. 1.2 lbs (500g) |
CO |
Range | 0 to
500PPM |
Accuracy | +/-3% of
reading or +/-3PPM whichever is
greater |
|
Resolution | 0.1PPM:
0-99PPM 1PPM: 100-500 PPM |
|
CO2 |
Range | 0 to 5000PPM |
Accuracy | +/-3% of
reading or+/-50PPM whichever is
greater |
|
Resolution | 1PPM | |
Temperature |
Range |
-
4 to 140F (-20 to 60C) |
Accuracy | +/- 1F (+/-0.5C) | |
Resolution |
0.1F
(0.1C ) |
|
Relative
Humidity |
Range | 2 to
98%RH |
Accuracy | 2 to
80%RH:±2%RH, 80 to 98%RH:±3%RH |
|
Resolution | 0.1%RH |
|
Function |
Normal
Mode |
Normal
measuring (do not store and
calculate the data.) Relative
humidity, CO, CO2, Dew point, Wet
bulb temperature, Absolute humidity
and Humidity Ratio |
Calculation
Mode |
Store
the
data, and calculate the maximum,
minimum and average value. |
|
%
OA Mode |
Measure
ventilation
ratio (Ask for ventilation ratio by
calculating from temperature and CO2
value) |
|
Data
Output
Mode |
Perform
re-calculation
of stored data and output of data to
PC and Printer. |
|
Calibration
Mode |
Perform
the
calibration of CO and CO2. |
|
Output |
Digital |
RS232C |
Analog
(option) |
DC 0 to 1V |
|
Power Supply | AAA Battery x 4 (Mn, Alkaline, or Ni-Cd) | |
Dimensions |
Unit |
3.5" x
7.5" x 2.0" |
Probe |
Length:
12.5 inch / Diameter: 1.0 inch |
|
Weight (including batteries) | Approx. 1.2 lbs (500g) |