Kane KANE258 Flue Gas Analyzer with direct CO, O2 and CO sensor protection

Model: KANE258

Kane KANE258 Flue Gas Analyzer with direct CO, O2 and CO sensor protection

Model: KANE258

Get direct CO, O2, and CO sensor protection with this flue gas analyzer which has an easy-to-use rotary dial and comes with an entry-level FGA for domestic gas applications. In addition, it has a purge pump protection that prevents damage to the CO sensor.

Get direct CO, O2, and CO sensor protection with this flue gas analyzer which has an easy-to-use rotary dial and comes with an entry-level FGA for domestic gas applications. In addition, it has a purge pump protection that prevents damage to the CO sensor.

Sale Price $930.95 CAD
Regular Price $949.95 CAD
Availability 2 to 3 Weeks
Quantity

Kane KANE258 Offers

Low flow detector system that switches off the analyzer's pump if it detects an over filled water trap.

Features

  • Rotary dial and six-line display
  • Data hold, log and print with user details to printer (sold separately)
  • Produce test reports: Combustion and temperature

Applications

  • Install and service domestic oil and gas appliances
  • Combustion performance checks
  • Combustion efficiency checks

Kane KANE258 Specifications

Measures CO: 0 to 2000 ppm
O2: 0 to 21%
Differential temperature
Calculates CO2: 0 to 20%
CO/CO2 ratio
Excess air
Combustion efficiency
Fuel Types Natural Gas, butane, LPG, light oil, wood pellets, propane
Battery Life >8 hours (continuous with pump on)
Operating Conditions Temperatures: 32 to 113°F (0 to 45°C)
Humidity: 15 to 90% RH, (non-condensing)
Power Supply Rechargeable batteries, USB charging
Dimensions 8.5 x 4.13 x 1.77" (216 x 105 x 45 mm)
Weight 0.0014 lbs (Approximately 0.625 g)

What's included with the Kane KANE258

  • Flue Gas Analyzer
  • Analyzer Calibration Certificate
  • Probe
  • USB Charger
  • Quick Reference Guide
  • 10-Year "No Quibble" Warranty When Recertified

Click on a category to view a selection of compatible accessories with the Kane KANE258 Flue Gas Analyzer with direct CO, O2 and CO sensor protection.

Kane CP2S Flue Probe for the KANE258/358/458s/457/958/988, 3.94" CP2S
Compatible with KANE258/358/458s/457/958/988 flue gas analyzers, this flue probe has a length of 3.94" (100 mm) with a molded handle and a shaft diameter of 0.24" (6 mm). In addition, it comes with a 39.37" (1000 mm) long hose.




Kane CP2T PTFE Lined Probe for the KANE258/358/458s/457/958/988, 11.22" CP2T
Compatible with the KANE258/358/458s/457/958/988 flue gas analyzers, this PTFE-lined probe has 0.31" (8 mm) diameter and comes with a 9.84" (3 m) neoprene hose. In addition, it has a shaft length of 11.22" (285 mm).




Kane SM14980 Flue Gas Probe Connector for the KANE258/358/458s/457/958/988 SM14980
Intended for use as a replacement, this flue gas probe connector is compatible with KANE258/358/458s/457/958/988 flue gas analyzers.




Ask a question about Kane KANE258 Flue Gas Analyzer with direct CO, O2 and CO sensor protection

Customer Reviews for the Kane KANE258

Kane KANE258 Offers

Low flow detector system that switches off the analyzer's pump if it detects an over filled water trap.

Features

  • Rotary dial and six-line display
  • Data hold, log and print with user details to printer (sold separately)
  • Produce test reports: Combustion and temperature

Applications

  • Install and service domestic oil and gas appliances
  • Combustion performance checks
  • Combustion efficiency checks

Kane KANE258 Specifications

Measures CO: 0 to 2000 ppm
O2: 0 to 21%
Differential temperature
Calculates CO2: 0 to 20%
CO/CO2 ratio
Excess air
Combustion efficiency
Fuel Types Natural Gas, butane, LPG, light oil, wood pellets, propane
Battery Life >8 hours (continuous with pump on)
Operating Conditions Temperatures: 32 to 113°F (0 to 45°C)
Humidity: 15 to 90% RH, (non-condensing)
Power Supply Rechargeable batteries, USB charging
Dimensions 8.5 x 4.13 x 1.77" (216 x 105 x 45 mm)
Weight 0.0014 lbs (Approximately 0.625 g)

What's included with the Kane KANE258

  • Flue Gas Analyzer
  • Analyzer Calibration Certificate
  • Probe
  • USB Charger
  • Quick Reference Guide
  • 10-Year "No Quibble" Warranty When Recertified

Click on a category to view a selection of compatible accessories with the Kane KANE258 Flue Gas Analyzer with direct CO, O2 and CO sensor protection.

Kane CP2S Flue Probe for the KANE258/358/458s/457/958/988, 3.94" CP2S
Compatible with KANE258/358/458s/457/958/988 flue gas analyzers, this flue probe has a length of 3.94" (100 mm) with a molded handle and a shaft diameter of 0.24" (6 mm). In addition, it comes with a 39.37" (1000 mm) long hose.




Kane CP2T PTFE Lined Probe for the KANE258/358/458s/457/958/988, 11.22" CP2T
Compatible with the KANE258/358/458s/457/958/988 flue gas analyzers, this PTFE-lined probe has 0.31" (8 mm) diameter and comes with a 9.84" (3 m) neoprene hose. In addition, it has a shaft length of 11.22" (285 mm).




Kane SM14980 Flue Gas Probe Connector for the KANE258/358/458s/457/958/988 SM14980
Intended for use as a replacement, this flue gas probe connector is compatible with KANE258/358/458s/457/958/988 flue gas analyzers.




Ask a question about Kane KANE258 Flue Gas Analyzer with direct CO, O2 and CO sensor protection

Customer Reviews for the Kane KANE258

More Kane Products