Ircon 5R-1810-0-0-0-RA IR Sensor, 700 to 1800°C (1292 to 3272°F)

Model: 5R-1810-0-0-0-RA

Ircon 5R-1810-0-0-0-RA IR Sensor, 700 to 1800°C (1292 to 3272°F)

Model: 5R-1810-0-0-0-RA

Self-contained, stand-alone infrared sensor that does not need a remote for operation. It has a thermo-electrically cooled detector and a total system health check that verifies that the temperature detector is working well.

Self-contained, stand-alone infrared sensor that does not need a remote for operation. It has a thermo-electrically cooled detector and a total system health check that verifies that the temperature detector is working well.

Discontinued!

This product has been discontinued and is no longer available.

There is no direct replacement, however we recommend the:

Fluke Process Instruments E1RL-F2-L-0-0 Endurance<sup>;</sup> Series Infrared High Temperature Ratio Pyrometers, 550 to 1800°C, Laser-

Fluke Process Instruments E1RL-F2-L-0-0 Endurance; Series Infrared High Temperature Ratio Pyrometers, 550 to 1800°C, Laser

Model: E1RL-F2-L-0-0

Endurance infrared sensors are designed with a rugged IP65 (NEMA 4) rated stainless steel housing to enable continuous visual process monitoring in harsh industrial environments.


Not what you're looking for? Let’s do a search and help you find what you need.


Ircon 5R-1810-0-0-0-RA IR Sensor Offers

Features

  • Self-contained, stand-alone infrared sensor, no remote electronics needed for operation
  • Thermo-electrically cooled detector
  • Total System Health Check diagnostics feature verifies that the temperature detector, internal circuitry and even the output signal are all working within factory specifications
  • Innovative Match Function allows you to input the process temperature (if known) and automatically adjust the emissivity
  • High resolution optics and adjustable focus enable precise targeting; distant objects can be measured using a very small focal area or "spot size"
  • Adjust focus by turning the rear portion of the sensor, which can be locked into position
  • Two built-in, thru-the-lens targeting options are available: visual or laser (optional)
  • Match Function takes the guess work out of setting emissivity
  • Optional Dirty Window Detector (DWD) can sense build-up on the window of the sensor and provide an alarm output to the user
  • Abilities to function both stand alone and networked, with standard I/O signal interfaces (both analog and bidirectional RS-485 digital) enable operation with other systems and devices
  • Sealed, stainless steel NEMA 4 (IP65) enclosure
  • Includes PC software for remote sensor setup and configuration
  • 2 µm unit with lower temperature range (down to 50°C/122°F)
  • Automatic internal self-calibration

Applications

Ideal for the following applications: Military, PhotoOptic, Pharmaceutical, Electrical.

Ircon 5R-1810-0-0-0-RA Specifications

Spectral Range 2.3 to 2.6µm
Accuracy ±0.3% rdg. +1°C or +2°C, whichever is greater
Response Time 20ms
Emissivity 0.100 to 1.000
Repeatability 0.1% f.s. + 1 digit @ 25°C
Analog Output 0-20mA, 4-20mA, 600Ω max.
Relay Output 24 VAC/VDC @ 1A resistive
Digital Input/Output RS-485 (57.6k baud)
Ambient Temperature Without Cooling: 0 to 55°C (32 to 130°F)
With Air Cooling: 0 to 105°C (32 to 220°F)
With Water Cooling: 0 to 200°C (32 to 400°F)

What's included with the Ircon 5R-1810-0-0-0-RA

  • Ircon 5R-1810-0-0-0-RA IR Sensor, 700 to 1800°C (1292 to 3272°F)

Ask a question about Ircon 5R-1810-0-0-0-RA IR Sensor, 700 to 1800°C (1292 to 3272°F)

Customer Reviews for the Ircon 5R-1810-0-0-0-RA

Ircon 5R-1810-0-0-0-RA IR Sensor Offers

Features

  • Self-contained, stand-alone infrared sensor, no remote electronics needed for operation
  • Thermo-electrically cooled detector
  • Total System Health Check diagnostics feature verifies that the temperature detector, internal circuitry and even the output signal are all working within factory specifications
  • Innovative Match Function allows you to input the process temperature (if known) and automatically adjust the emissivity
  • High resolution optics and adjustable focus enable precise targeting; distant objects can be measured using a very small focal area or "spot size"
  • Adjust focus by turning the rear portion of the sensor, which can be locked into position
  • Two built-in, thru-the-lens targeting options are available: visual or laser (optional)
  • Match Function takes the guess work out of setting emissivity
  • Optional Dirty Window Detector (DWD) can sense build-up on the window of the sensor and provide an alarm output to the user
  • Abilities to function both stand alone and networked, with standard I/O signal interfaces (both analog and bidirectional RS-485 digital) enable operation with other systems and devices
  • Sealed, stainless steel NEMA 4 (IP65) enclosure
  • Includes PC software for remote sensor setup and configuration
  • 2 µm unit with lower temperature range (down to 50°C/122°F)
  • Automatic internal self-calibration

Applications

Ideal for the following applications: Military, PhotoOptic, Pharmaceutical, Electrical.

Ircon 5R-1810-0-0-0-RA Specifications

Spectral Range 2.3 to 2.6µm
Accuracy ±0.3% rdg. +1°C or +2°C, whichever is greater
Response Time 20ms
Emissivity 0.100 to 1.000
Repeatability 0.1% f.s. + 1 digit @ 25°C
Analog Output 0-20mA, 4-20mA, 600Ω max.
Relay Output 24 VAC/VDC @ 1A resistive
Digital Input/Output RS-485 (57.6k baud)
Ambient Temperature Without Cooling: 0 to 55°C (32 to 130°F)
With Air Cooling: 0 to 105°C (32 to 220°F)
With Water Cooling: 0 to 200°C (32 to 400°F)

What's included with the Ircon 5R-1810-0-0-0-RA

  • Ircon 5R-1810-0-0-0-RA IR Sensor, 700 to 1800°C (1292 to 3272°F)

Ask a question about Ircon 5R-1810-0-0-0-RA IR Sensor, 700 to 1800°C (1292 to 3272°F)

Customer Reviews for the Ircon 5R-1810-0-0-0-RA

More Ircon Products