Streamline UPS and lead-acid battery diagnostics with this battery tester pro kit which is designed to measure and record guidance. In addition, this kit includes an L-shaped pin-type lead, which lets you reach deep into the battery racks and probe the entire terminals.
Streamline UPS and lead-acid battery diagnostics with this battery tester pro kit which is designed to measure and record guidance. In addition, this kit includes an L-shaped pin-type lead, which lets you reach deep into the battery racks and probe the entire terminals.
Compatible with many battery types, including lead-acid, nickel-cadmium and nickel-hydride batteries. Plus, it comes with a carrying case for easy transportation to and from work sites.
Features
The battery tester sets a new standard for UPS and lead-acid battery diagnostics. Since the battery’s internal resistance and voltage are measured using the impedance method, diagnostics can be performed while the battery is connected to its host device, without taking it offline. Proprietary noise reduction technology allows more accurate measurement, even in noisy environments.
When the battery tester is paired with a dedicated mobile app (GENNECT Cross), the mobile device will provide audio guidance announcing the next battery number to be measured. This feature helps prevent erroneous measurements. You can also set up measurement locations information and battery numbers in advance to create profiles to which measurement data and diagnostic results will be linked. This capability simplifies data management, even when performing diagnostic work on large numbers of batteries.
By using its comparator function to simultaneously measure the internal resistance and voltage of a lead-acid, nickel-cadmium, or nickel-hydride battery, the battery tester can generate comparative judgments quantifying degradation of the cell based on user-specified threshold values. Furthermore, voltage sign detection facilitates instantaneous determination of whether batteries have been connected properly in newly installed UPS systems.
The battery tester's auto-hold function automatically holds measured values once they stabilize. The instrument’s auto-memory function, which automatically stores measured values resulting from the auto-hold function in its internal memory, further streamlines work tasks.
The pin-type lead with L-shaped tips significantly improves ease of use when inspecting batteries installed in confined locations.
If you’re measuring a number of batteries in a large area, use the included shoulder strap to carry the instrument with you while making measurements.
Simply touch the test leads to the battery terminals to easily capture battery condition data. Automatically save measurements results using the auto-hold or auto-memory function in just 2 seconds.
Applications
Deterioration judgment of stationary lead-acid batteries
Resistance Measurement Range | 3 mΩ (max. display 3.100 mΩ, resolution 1 μΩ) to 3 Ω (max. display 3.100 Ω, resolution 1 mΩ), 4 ranges Accuracy: ±0.8 % rdg ±6 dgt (3 mΩ range: ±1 % rdg ±8 dgt) Testing source frequency: 1 kHz ±30 Hz With function for avoiding noise frequency enabled: 1 kHz ±80 Hz Testing current: 160 mA (3m/30 mΩ range), 16 mA (300 mΩ range), 1.6 mA (3 Ω range) Open terminal voltage: 5 V peak |
Voltage Measurement Range | ±6 V (maximum display ±6.000 V, resolution: 1 mV) to ±60 V (maximum display ±60.00 V, resolution: 10 mV), 2 ranges, Accuracy: ±0.08% rdg ±6 dgt |
Temperature Measurement Accuracy | Measurement range: 14 to 140°F (-10 to 60°C) Maximum display: 140°F (60°C) Resolution: 0.1°F (0.1°C) Measurement accuracy: ±1.8°F (±1°C) * When using the clip type lead with temperature sensor 9460 * When using the temperature probe 9451, add ±0.9°F (±0.5°C) (cable length: 59.1" [1.5 m]). * When using the temperature probe 9451S, add ±0.9°F (±0.5°C) (cable length: 3.94" [0.1 m]). BT3554-50 standalone accuracy with simulated input: ±0.9°F (±0.5°C) |
Absolute Maximum Input Voltage | 60 V DC maximum (no AC input) |
Measurement Time | 100 ms |
Response Time | Approximately 1.6 seconds |
Comparator | Compares measured values with set threshold values to make judgments and reports them to the user. Judgment notification method: Results are displayed as shown below (segment) and beeping tones sound When the Voltage value (high): Resistance value (low)= PASS, Resistance value (medium)= WARNING, Resistance value (high)= FAIL When the Voltage value (low): Resistance value (low)= WARNING, Resistance value (medium)= WARNING, Resistance value (high)= FAIL If the judgment result is WARNING or FAIL, the audio tone is accompanied by a red backlight. User-selectable voltage judgment method: ABS (absolute value judgment), POL (polarity judgment ) Savable settings: 200 tables |
Memory Functionality | Operation: Save, load, and delete measurement data, Save and delete profile information, Number of data sets: 6000, Memory architecture: 500 data sets per unit (12 units) Saved data: Saved measurement data is linked to profile information. 1. Measurement data: Data can be saved, loaded, and deleted by operating the instrument. -1. Date and time -2. Resistance value, voltage value, and temperature -3. Comparator threshold value and judgment result 2. Profile information: Profile information can be saved, loaded, and deleted using a supported application (GENNECT Cross or GENNECT One). -1. Profile numbers: 1 to 100 (Data (2), (3), and (4) below are saved for each profile number) -2. Location: User-defined comment such as location of UPS -3. Device information: User-defined comment such as UPS management number -4. Battery number: 1 to 500 (start number, end number) |
Measurement Navigator | Operation: Announces the next battery number to be measured via a screen display and audio guidance Preparations: Profile information that's been registered with a supported application (GENNECT Cross or GENNECT One) must be transferred to the instrument |
Communication Interface | USB |
Other Functions | Temperature measurement 14 to 140°F (-10 to 60°C), zero-adjustment, hold, auto-hold, auto-memory, auto-power-save, clock |
Power Supply | 8 x LR6 (AA) alkaline dry battery Continuous operating time: About 8.3 hours |
Dimensions | 7.83 x 5.20 x 2.39" (199 x 132 x 60.6 mm) with protector |
Weight | 33.9 oz (960 g) including batteries and protector |
Battery Tester with Bluetooth
Pin Type Lead
Protector
Adjustment Board
Precautions For Radio-Wave Emitting Equipment
Power-On Option Sticker
Spare Fuse
USB Cable
Carrying Case
8 x LR6 (AA) Alkaline Batteries
Application Software CD
User's Manual
Resistance Measurement Range | 3 mΩ (max. display 3.100 mΩ, resolution 1 μΩ) to 3 Ω (max. display 3.100 Ω, resolution 1 mΩ), 4 ranges Accuracy: ±0.8 % rdg ±6 dgt (3 mΩ range: ±1 % rdg ±8 dgt) Testing source frequency: 1 kHz ±30 Hz With function for avoiding noise frequency enabled: 1 kHz ±80 Hz Testing current: 160 mA (3m/30 mΩ range), 16 mA (300 mΩ range), 1.6 mA (3 Ω range) Open terminal voltage: 5 V peak |
Voltage Measurement Range | ±6 V (maximum display ±6.000 V, resolution: 1 mV) to ±60 V (maximum display ±60.00 V, resolution: 10 mV), 2 ranges, Accuracy: ±0.08% rdg ±6 dgt |
Temperature Measurement Accuracy | Measurement range: 14 to 140°F (-10 to 60°C) Maximum display: 140°F (60°C) Resolution: 0.1°F (0.1°C) Measurement accuracy: ±1.8°F (±1°C) * When using the clip type lead with temperature sensor 9460 * When using the temperature probe 9451, add ±0.9°F (±0.5°C) (cable length: 59.1" [1.5 m]). * When using the temperature probe 9451S, add ±0.9°F (±0.5°C) (cable length: 3.94" [0.1 m]). BT3554-50 standalone accuracy with simulated input: ±0.9°F (±0.5°C) |
Absolute Maximum Input Voltage | 60 V DC maximum (no AC input) |
Measurement Time | 100 ms |
Response Time | Approximately 1.6 seconds |
Comparator | Compares measured values with set threshold values to make judgments and reports them to the user. Judgment notification method: Results are displayed as shown below (segment) and beeping tones sound When the Voltage value (high): Resistance value (low)= PASS, Resistance value (medium)= WARNING, Resistance value (high)= FAIL When the Voltage value (low): Resistance value (low)= WARNING, Resistance value (medium)= WARNING, Resistance value (high)= FAIL If the judgment result is WARNING or FAIL, the audio tone is accompanied by a red backlight. User-selectable voltage judgment method: ABS (absolute value judgment), POL (polarity judgment ) Savable settings: 200 tables |
Memory Functionality | Operation: Save, load, and delete measurement data, Save and delete profile information, Number of data sets: 6000, Memory architecture: 500 data sets per unit (12 units) Saved data: Saved measurement data is linked to profile information. 1. Measurement data: Data can be saved, loaded, and deleted by operating the instrument. -1. Date and time -2. Resistance value, voltage value, and temperature -3. Comparator threshold value and judgment result 2. Profile information: Profile information can be saved, loaded, and deleted using a supported application (GENNECT Cross or GENNECT One). -1. Profile numbers: 1 to 100 (Data (2), (3), and (4) below are saved for each profile number) -2. Location: User-defined comment such as location of UPS -3. Device information: User-defined comment such as UPS management number -4. Battery number: 1 to 500 (start number, end number) |
Measurement Navigator | Operation: Announces the next battery number to be measured via a screen display and audio guidance Preparations: Profile information that's been registered with a supported application (GENNECT Cross or GENNECT One) must be transferred to the instrument |
Communication Interface | USB |
Other Functions | Temperature measurement 14 to 140°F (-10 to 60°C), zero-adjustment, hold, auto-hold, auto-memory, auto-power-save, clock |
Power Supply | 8 x LR6 (AA) alkaline dry battery Continuous operating time: About 8.3 hours |
Dimensions | 7.83 x 5.20 x 2.39" (199 x 132 x 60.6 mm) with protector |
Weight | 33.9 oz (960 g) including batteries and protector |
Battery Tester with Bluetooth
Pin Type Lead
Protector
Adjustment Board
Precautions For Radio-Wave Emitting Equipment
Power-On Option Sticker
Spare Fuse
USB Cable
Carrying Case
8 x LR6 (AA) Alkaline Batteries
Application Software CD
User's Manual