Hanna HI99121 Direct Soil Measurement pH Portable Meter

Model: HI99121 | Order No: HI 99121

Hanna HI99121 Direct Soil Measurement pH Portable Meter

Model: HI99121 | Order No: HI 99121

The perfect portable pH meter for soil testing. Test both pH of soil directly or after preparation of a soil slurry with deionized water. Features a conical, rugged tip that can be directly inserted into moist or soft soil. For harder soils, the kit includes a plastic auger to perforate the ground.

The perfect portable pH meter for soil testing. Test both pH of soil directly or after preparation of a soil slurry with deionized water. Features a conical, rugged tip that can be directly inserted into moist or soft soil. For harder soils, the kit includes a plastic auger to perforate the ground.

Sale Price $591.85 CAD
Regular Price $623.00 CAD
Availability 1 in Stock
Quantity

Hanna HI99121 Offers

The HI99121 meter features a large multi level LCD screen which displays both pH and temperature readings simultaneously with 0.01 pH resolution and an accuracy of ±0.05 pH. The LCD screen also has indicators for calibration status and stability, as well as on-screen tutorial messages. The HI99121 has many advanced features that are found in more expensive portable instrumentation including automatic calibration, buffer recognition,and temperature compensation.

Features

  • Conical, rugged tip that can be directly inserted into moist or soft soil
  • Automatic Temperature Compensation
  • Automatic Two-Point Calibration
  • Waterproof
  • Refillable
  • Built-in Temperature Sensor
  • Amplified Electrode
  • BEPS- Alerts the user of low battery power that could adversely affect readings
  • Compact, heavy-duty
  • Battery % displayed on start-up
  • HELP feature, displays messages on LCD

Are you Making Errors with Measuring pH?

  • Storing the Electrode
  • Wiping the Sensing Glass
  • Storing the Electrode in DI Water
  • Not Cleaning the Electrode
  • Calibration Errors
  • Electrode Selection
  • Not Loosening or Removing the Fill Hole Cap
  • Electrolyte Fill Level
  • Inadequate Probe Submersion
  • Using an Old or Expired Electrode

Five Tips for Calibrating your pH Meter

  • Always Read your Manual
  • Make Sure you Have the Right pH Buffers
  • Calibrate Often
  • Be Aware of your Slope and Offset
  • Electrode Care

Hanna HI99121 Specifications

pH Range -2.00 to 16.00 pH
pH Resolution 0.01 pH
pH Accuracy ±0.02 pH
pH Calibration Automatic, at one or two points with two sets of standard buffers (pH 4.01 / 7.01 / 10.01 or pH 4.01 / 6.86 / 9.18)
Temperature Range -5.0 to 80.0°C / 23.0 to 176.0°F
Temperature Resolution 0.1°C / 0.1°F
Temperature Accuracy ±0.5°C (up to 60°C); ±1.0°C (outside) / ±1°F (up to 140°F); ±2.0°F (outside)
Temperature Compensation Automatic from -5.0 to 105.0ºC (23 to 221ºF)
Click here for complete specifications on the Hanna HI99121

What's included with the Hanna HI99121

  • Direct Soil Measurement pH Portable Meter
  • pH Electrode
  • Soil Auger
  • Soil Preparation Solution (230 mL)
  • pH 4.01 Buffer Solution Sachet (20 mL)
  • pH 7.01 Buffer Solution Sachet (20 mL)
  • Cleaning Solution Sachet for Inorganic Soil Deposits (20 mL)
  • Cleaning Solution Sachet for Organic Soil Deposits (20 mL)
  • 100 mL Plastic Beaker
  • Batteries
  • Instructions
  • Hard Carrying Case

Click on a category to view a selection of compatible accessories with the Hanna HI99121 Direct Soil Measurement pH Portable Meter.



Hanna HI7004M Calibration Solution, pH 4.01, 230 mL HI7004M
HI7004M is a premium quality pH 4.01 calibration solution. Hanna's line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.




Hanna HI7006M Calibration Solution, pH 6.86, 230 mL HI7006M
HI7006M is a premium quality pH 6.86 calibration solution. Hanna's line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.




Hanna HI7082L Electrolyte Solution 3.5M KCI, 460 mL HI7082L
Electrolyte solution to ensure the correct electrode performance.




Hanna HI70663L Cleaning Solution for Soil Deposits, 500 mL HI70663L
Eliminate impurities and residues left on electrode surfaces when immersed in samples during measurement with this acidic cleaning solution. In addition, this solution is specially formulated for pH electrodes used in agricultural applications.




Hanna HI70664L Cleaning Solution for Humus Deposits, 500 mL HI70664L
An effective, alkaline cleaning solution that is specially formulated for cleaning pH electrodes used in agricultural applications with humus organic soil matter.




Hanna HI70300L Electrode Storage Solution, 500 mL HI70300L
A storage solution prepared with reagent grade chemicals that can be used to ensure optimum performance of your pH and ORP electrodes. It is necessary to store a pH electrode in a solution in order to keep the glass membrane of the pH electrode hydrated.




Ask a question about Hanna HI99121 Direct Soil Measurement pH Portable Meter

Customer Reviews for the Hanna HI99121

Hanna HI99121 Offers

The HI99121 meter features a large multi level LCD screen which displays both pH and temperature readings simultaneously with 0.01 pH resolution and an accuracy of ±0.05 pH. The LCD screen also has indicators for calibration status and stability, as well as on-screen tutorial messages. The HI99121 has many advanced features that are found in more expensive portable instrumentation including automatic calibration, buffer recognition,and temperature compensation.

Features

  • Conical, rugged tip that can be directly inserted into moist or soft soil
  • Automatic Temperature Compensation
  • Automatic Two-Point Calibration
  • Waterproof
  • Refillable
  • Built-in Temperature Sensor
  • Amplified Electrode
  • BEPS- Alerts the user of low battery power that could adversely affect readings
  • Compact, heavy-duty
  • Battery % displayed on start-up
  • HELP feature, displays messages on LCD

Are you Making Errors with Measuring pH?

  • Storing the Electrode
  • Wiping the Sensing Glass
  • Storing the Electrode in DI Water
  • Not Cleaning the Electrode
  • Calibration Errors
  • Electrode Selection
  • Not Loosening or Removing the Fill Hole Cap
  • Electrolyte Fill Level
  • Inadequate Probe Submersion
  • Using an Old or Expired Electrode

Five Tips for Calibrating your pH Meter

  • Always Read your Manual
  • Make Sure you Have the Right pH Buffers
  • Calibrate Often
  • Be Aware of your Slope and Offset
  • Electrode Care

Hanna HI99121 Specifications

pH Range -2.00 to 16.00 pH
pH Resolution 0.01 pH
pH Accuracy ±0.02 pH
pH Calibration Automatic, at one or two points with two sets of standard buffers (pH 4.01 / 7.01 / 10.01 or pH 4.01 / 6.86 / 9.18)
Temperature Range -5.0 to 80.0°C / 23.0 to 176.0°F
Temperature Resolution 0.1°C / 0.1°F
Temperature Accuracy ±0.5°C (up to 60°C); ±1.0°C (outside) / ±1°F (up to 140°F); ±2.0°F (outside)
Temperature Compensation Automatic from -5.0 to 105.0ºC (23 to 221ºF)
Click here for complete specifications on the Hanna HI99121

What's included with the Hanna HI99121

  • Direct Soil Measurement pH Portable Meter
  • pH Electrode
  • Soil Auger
  • Soil Preparation Solution (230 mL)
  • pH 4.01 Buffer Solution Sachet (20 mL)
  • pH 7.01 Buffer Solution Sachet (20 mL)
  • Cleaning Solution Sachet for Inorganic Soil Deposits (20 mL)
  • Cleaning Solution Sachet for Organic Soil Deposits (20 mL)
  • 100 mL Plastic Beaker
  • Batteries
  • Instructions
  • Hard Carrying Case

Click on a category to view a selection of compatible accessories with the Hanna HI99121 Direct Soil Measurement pH Portable Meter.



Hanna HI7004M Calibration Solution, pH 4.01, 230 mL HI7004M
HI7004M is a premium quality pH 4.01 calibration solution. Hanna's line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.




Hanna HI7006M Calibration Solution, pH 6.86, 230 mL HI7006M
HI7006M is a premium quality pH 6.86 calibration solution. Hanna's line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.




Hanna HI7082L Electrolyte Solution 3.5M KCI, 460 mL HI7082L
Electrolyte solution to ensure the correct electrode performance.




Hanna HI70663L Cleaning Solution for Soil Deposits, 500 mL HI70663L
Eliminate impurities and residues left on electrode surfaces when immersed in samples during measurement with this acidic cleaning solution. In addition, this solution is specially formulated for pH electrodes used in agricultural applications.




Hanna HI70664L Cleaning Solution for Humus Deposits, 500 mL HI70664L
An effective, alkaline cleaning solution that is specially formulated for cleaning pH electrodes used in agricultural applications with humus organic soil matter.




Hanna HI70300L Electrode Storage Solution, 500 mL HI70300L
A storage solution prepared with reagent grade chemicals that can be used to ensure optimum performance of your pH and ORP electrodes. It is necessary to store a pH electrode in a solution in order to keep the glass membrane of the pH electrode hydrated.




Ask a question about Hanna HI99121 Direct Soil Measurement pH Portable Meter

Customer Reviews for the Hanna HI99121

More Hanna Products