Hanna HI2002 edge Dedicated pH/ORP Meter

Model: HI2002 | Order No: HI 2002-01

Hanna HI2002 edge Dedicated pH/ORP Meter

Model: HI2002 | Order No: HI 2002-01

The innovative meter edge® design offers an easy to use meter that can measure pH and ORP. Incredibly versatile, and can be used in a variety of environments without taking up the space of a traditional benchtop meter.

The innovative meter edge® design offers an easy to use meter that can measure pH and ORP. Incredibly versatile, and can be used in a variety of environments without taking up the space of a traditional benchtop meter.

Sale Price $527.25 CAD
Regular Price $555.00 CAD
Availability 1 in Stock
Quantity

Hanna HI2002 Offers

The body of the meter is about half the size of a mini-tablet and is only 0.5" thick. The keypad being part of a screen allows for accidental benchtop spills to be wiped right off the screen. Not only is t portable, but it also has an internal memory that can store up to 1,000 readings.

Features

  • Advanced pH electrode diagnostics
  • Easy clean touch keypad
  • Capacitive Touch
  • Large, easy to read LCD
  • Digital pH electrodes
  • CAL Check
  • Sensor check
  • Wall mount
  • 3.5mm probe input
  • Cradle and electrode holder
  • Two USB Ports
  • Data logging
  • Two operating modes

Benchtop

It can sit on a benchtop stand with a spring-loaded probe holder, great for any kind of lab and benchtop pH applications.

Wall Mount

Can be used in a handy wall-mounted cradle, a good space saving alternative! The cradle also serves as a battery charger.

Portable

Fully portable; it can be taken out of the cradle and run on battery power as a handheld meter.

Wine-Specific Probe

  • Clog Prevention Sleeve (CPS)
  • Embedded microchip stores profile
  • Specific glass bulb for fast response

It features a special Clogging Prevention System (CPS) that prevents suspended solids from blocking the junction (the channel for electrolyte to flow). This probe has a built in temperature sensor, allowing the meter to adjust your pH readings to standard conditions.

In the winery, this can make a difference when you are reading your wine pH values at or just after fermentation (when they are likely to be warmer) versus in the middle of the winter, when wines in barrels or tanks might be at around 55°F.

This probe, like all probes for edge®, has a built-in microchip that stores sensor type, serial number, and calibration information. What this does for you is it allows the meter to instantly recognize which probe it is connected and when calibration needs to be performed.

Are you Making Errors when Measuring pH?

  • Storing the electrode dry
  • Wiping the sensing glass
  • Storing the electrode in DI water
  • Not cleaning the electrode
  • Calibration errors
  • Electrode selection
  • Not loosening or removing the fill hole cap
  • Electrolyte fill level
  • Inadequate probe submersion
  • Using an old or expired electrode

Hanna HI2002 Specifications

pH
Range Standard Mode: -2.000 to 16.000 pH
Basic Mode: -2.00 to 16.00 pH
Resolution 0.001 pH, 0.01 pH
Accuracy (@25°C/77°F) ±0.01 pH, ±0.002 pH
Calibration 5 points (Standard mode) 1.68, 4.01 (3.00†), 6.86, 7.01, 9.18, 10.01, 12.45, and two custom buffers; 3 points (Basic mode) 4.01; 6.86; 7.01; 9.18; 10.01
Temperature Compensation ATC: -5.0 to 100.0°C; 23.0 to 212.0°F
mV
Range ±1000.0 mV; ±2000.0 mV
Resolution 0.1 mV
Accuracy ±0.2 mV (±999.9 mV); ±1 mV (±2000 mV)
Click here for complete specifications on the Hanna HI2002

What's included with the Hanna HI2002

  • Dedicated pH/ORP Meter
  • Benchtop Docking Station with Electrode Holder
  • Wall Mount Cradle
  • USB Cable
  • Glass Body
  • Refillable pH Electrode with Temperature Sensor
  • 2 x Sachets each of pH 4, 7, 10, Cleaning Solution
  • 5 VDC Power Adapter
  • Instruction Manual

Click on a category to view a selection of compatible accessories with the Hanna HI2002 edge Dedicated pH/ORP Meter.

Hanna Instruments HI7004L 4.01 pH Buffer Solution 1 x 500 mL bottle HI7004L
Hanna's buffer solutions are prepared according to precise formulas and are standardized with a pH meter calibrated according to the NIST standards. The 20 mL sachets are single-dose whereas, for more demanding applications, you may choose between packages of 230 mL, 500 mL, 1 Liter or 1 Gallon (3.78 L). All pH 4 solutions show batch number, expiration date and the correlation table between pH and temperature. This buffer value is widely used in water purification plants, in the food industry and where ever the pH is expected to be slightly acidic.




Hanna HI7082L Electrolyte Solution 3.5M KCI, 460 mL HI7082L
Electrolyte solution to ensure the correct electrode performance.




Hanna HI70300L Electrode Storage Solution, 500 mL HI70300L
A storage solution prepared with reagent grade chemicals that can be used to ensure optimum performance of your pH and ORP electrodes. It is necessary to store a pH electrode in a solution in order to keep the glass membrane of the pH electrode hydrated.




Hanna HI7010L Calibration Solution, pH 10.01, 500 mL HI7010L
Calibration buffer solution with a pH of 10.01. The lot number and expiration date are clearly marked on the label, with an air tight and tamper proof seal, to ensure the quality of the solution. Hanna's line of calibration buffers have been specially formulated to have an expiration of 2 years from the date of manufacture for an unopened bottle.




Hanna HI7061L General Purpose Cleaning Solution, 500 mL HI7061L
Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. This is a general cleaning solution that can be used for a variety of applications.




Hanna HI7007L Calibration Solution, pH 7.01, 500 mL HI7007L
Calibration buffer solution with a pH of 7.01. The lot number and expiration date are clearly marked on the label, with an air tight and tamper proof seal, to ensure the quality of the solution. Hanna's line of calibration buffers have been specially formulated to have an expiration of 2 years from the date of manufacture for an unopened bottle.




Hanna HI7082M Electrolyte Solution 3.5M KCl, 230 mL HI7082M
This is a pH and ORP electrode fill solution that contains 3.5M KCl, which is specifically produced for double junction electrodes.




Hanna HI12300 Digital PEI Body pH Electrode for Field Applications HI12300
Plastic body, double junction, gel filled pH electrode, with a built-in temperature sensor for temperature compensated measurements in a single probe design.




Hanna HI10480 Digital Glass Body pH Electrode with Clogging Prevention System HI10480
Digital pH electrode with a built-in temperature sensor, specifically designed for measuring the pH in wine.




Ask a question about Hanna HI2002 edge Dedicated pH/ORP Meter

Customer Reviews for the Hanna HI2002

Hanna HI2002 Offers

The body of the meter is about half the size of a mini-tablet and is only 0.5" thick. The keypad being part of a screen allows for accidental benchtop spills to be wiped right off the screen. Not only is t portable, but it also has an internal memory that can store up to 1,000 readings.

Features

  • Advanced pH electrode diagnostics
  • Easy clean touch keypad
  • Capacitive Touch
  • Large, easy to read LCD
  • Digital pH electrodes
  • CAL Check
  • Sensor check
  • Wall mount
  • 3.5mm probe input
  • Cradle and electrode holder
  • Two USB Ports
  • Data logging
  • Two operating modes

Benchtop

It can sit on a benchtop stand with a spring-loaded probe holder, great for any kind of lab and benchtop pH applications.

Wall Mount

Can be used in a handy wall-mounted cradle, a good space saving alternative! The cradle also serves as a battery charger.

Portable

Fully portable; it can be taken out of the cradle and run on battery power as a handheld meter.

Wine-Specific Probe

  • Clog Prevention Sleeve (CPS)
  • Embedded microchip stores profile
  • Specific glass bulb for fast response

It features a special Clogging Prevention System (CPS) that prevents suspended solids from blocking the junction (the channel for electrolyte to flow). This probe has a built in temperature sensor, allowing the meter to adjust your pH readings to standard conditions.

In the winery, this can make a difference when you are reading your wine pH values at or just after fermentation (when they are likely to be warmer) versus in the middle of the winter, when wines in barrels or tanks might be at around 55°F.

This probe, like all probes for edge®, has a built-in microchip that stores sensor type, serial number, and calibration information. What this does for you is it allows the meter to instantly recognize which probe it is connected and when calibration needs to be performed.

Are you Making Errors when Measuring pH?

  • Storing the electrode dry
  • Wiping the sensing glass
  • Storing the electrode in DI water
  • Not cleaning the electrode
  • Calibration errors
  • Electrode selection
  • Not loosening or removing the fill hole cap
  • Electrolyte fill level
  • Inadequate probe submersion
  • Using an old or expired electrode

Hanna HI2002 Specifications

pH
Range Standard Mode: -2.000 to 16.000 pH
Basic Mode: -2.00 to 16.00 pH
Resolution 0.001 pH, 0.01 pH
Accuracy (@25°C/77°F) ±0.01 pH, ±0.002 pH
Calibration 5 points (Standard mode) 1.68, 4.01 (3.00†), 6.86, 7.01, 9.18, 10.01, 12.45, and two custom buffers; 3 points (Basic mode) 4.01; 6.86; 7.01; 9.18; 10.01
Temperature Compensation ATC: -5.0 to 100.0°C; 23.0 to 212.0°F
mV
Range ±1000.0 mV; ±2000.0 mV
Resolution 0.1 mV
Accuracy ±0.2 mV (±999.9 mV); ±1 mV (±2000 mV)
Click here for complete specifications on the Hanna HI2002

What's included with the Hanna HI2002

  • Dedicated pH/ORP Meter
  • Benchtop Docking Station with Electrode Holder
  • Wall Mount Cradle
  • USB Cable
  • Glass Body
  • Refillable pH Electrode with Temperature Sensor
  • 2 x Sachets each of pH 4, 7, 10, Cleaning Solution
  • 5 VDC Power Adapter
  • Instruction Manual

Click on a category to view a selection of compatible accessories with the Hanna HI2002 edge Dedicated pH/ORP Meter.

Hanna Instruments HI7004L 4.01 pH Buffer Solution 1 x 500 mL bottle HI7004L
Hanna's buffer solutions are prepared according to precise formulas and are standardized with a pH meter calibrated according to the NIST standards. The 20 mL sachets are single-dose whereas, for more demanding applications, you may choose between packages of 230 mL, 500 mL, 1 Liter or 1 Gallon (3.78 L). All pH 4 solutions show batch number, expiration date and the correlation table between pH and temperature. This buffer value is widely used in water purification plants, in the food industry and where ever the pH is expected to be slightly acidic.




Hanna HI7082L Electrolyte Solution 3.5M KCI, 460 mL HI7082L
Electrolyte solution to ensure the correct electrode performance.




Hanna HI70300L Electrode Storage Solution, 500 mL HI70300L
A storage solution prepared with reagent grade chemicals that can be used to ensure optimum performance of your pH and ORP electrodes. It is necessary to store a pH electrode in a solution in order to keep the glass membrane of the pH electrode hydrated.




Hanna HI7010L Calibration Solution, pH 10.01, 500 mL HI7010L
Calibration buffer solution with a pH of 10.01. The lot number and expiration date are clearly marked on the label, with an air tight and tamper proof seal, to ensure the quality of the solution. Hanna's line of calibration buffers have been specially formulated to have an expiration of 2 years from the date of manufacture for an unopened bottle.




Hanna HI7061L General Purpose Cleaning Solution, 500 mL HI7061L
Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. This is a general cleaning solution that can be used for a variety of applications.




Hanna HI7007L Calibration Solution, pH 7.01, 500 mL HI7007L
Calibration buffer solution with a pH of 7.01. The lot number and expiration date are clearly marked on the label, with an air tight and tamper proof seal, to ensure the quality of the solution. Hanna's line of calibration buffers have been specially formulated to have an expiration of 2 years from the date of manufacture for an unopened bottle.




Hanna HI7082M Electrolyte Solution 3.5M KCl, 230 mL HI7082M
This is a pH and ORP electrode fill solution that contains 3.5M KCl, which is specifically produced for double junction electrodes.




Hanna HI12300 Digital PEI Body pH Electrode for Field Applications HI12300
Plastic body, double junction, gel filled pH electrode, with a built-in temperature sensor for temperature compensated measurements in a single probe design.




Hanna HI10480 Digital Glass Body pH Electrode with Clogging Prevention System HI10480
Digital pH electrode with a built-in temperature sensor, specifically designed for measuring the pH in wine.




Ask a question about Hanna HI2002 edge Dedicated pH/ORP Meter

Customer Reviews for the Hanna HI2002

More Hanna Products