Hanna HI 98198 Optical Dissolved Oxygen Meter Kit

Model: HI 98198

Hanna HI 98198 Optical Dissolved Oxygen Meter Kit

Model: HI 98198

Utilize this DO kit to measure dissolved oxygen in your water samples. The kit comes with a hard carrying case to accommodate both field and lab use.

Utilize this DO kit to measure dissolved oxygen in your water samples. The kit comes with a hard carrying case to accommodate both field and lab use.

Sale Price $2122.30 CAD
Regular Price $2234.00 CAD
Availability 1 to 2 Weeks
Quantity

Hanna HI 98198 Offers



The Hanna HI 98198 Optical Dissolved Oxygen Meter Kit produces readings you can rely on. It's made from highly durable materials and advanced technologies to provide you with long-lasting accuracy. It can even log up to 4,000 individual readings. Plus, the DO meter comes with a probe and various accessories and solutions.

Features

  • Measures the concentration of dissolved oxygen in water
  • Requires no membranes, no filling solution and no warm-up time
  • Optical DO technology ensures stable, accurate readings
  • IP67-rated body is rugged and waterproof
  • GLP data: date, time, pressure, calibrated value, temperature and salinity value of the last calibration
  • Data logging function can save up to 4,000 readings
  • USB-C port makes transferring data easy
  • Probe is made with an IP68-rated ABS body and stainless-steel guard to resist water and dust
  • Smart Cap™ technology with built-in RFID reader
  • Includes assortment of accessories and solutions
  • Automatic shutoff modes: 5, 10, 30 and 60 minutes or disabled
  • Applications Saltwater, Freshwater

Hanna HI 98198 Specifications


DO Range0 to 50 mg/L, 0 to 500% saturation
DO Resolution0.01 mg/L, 0.1% saturation
DO Accuracy1.5% of reading ±0.01mg/L for 0 to 20 mg/L; 5% of reading for 20 to 50 mg/L; 1.5% of reading ±0.1% for 0 to 200%; 5% of reading for 200 to 500%
DO CalibrationManual or automatic (1 or 2 points)
DO Temperature CompensationAutomatic from 23 to 122°F (-5 to 50°C)
Barometric Pressure CompensationSingle point anywhere within pressure range
Salinity CompensationAutomatic from 0 to 70 PSU (manually set)
Altitude CompensationAutomatic from 420 to 850 mmHg
Temperature Range23 to 122°F (-5 to 50°C)
Temperature Resolution0.1°
Temperature Accuracy±0.4°F (±0.3°C)
DisplayBacklit LCD
AutoEndYes
Battery Life~200 hours of continuous use without backlight; ~50 hours with backlight
Environment32 to 122°F (0 to 50°C); 100% RH max
Product Length7.3" (185 mm); 13' (4 m) probe cable
Product Width3.6" (93 mm)
Product Height1.4" (35.2 mm)
Product Weight15.9 oz (450 g)
Manufacturer Warranty2 years meter and probe; 1 year Smart Cap™

What's included with the Hanna HI 98198


  • Meter
  • HI 764113 Probe
  • Smart Cap™ with O-Ring
  • Bicomponent Zero Oxygen Solution
  • Calibration/Storage Vessel
  • 2 x Plastic Beakers
  • Syringe with Silicone Grease
  • Lens Wipe
  • 4 x 1.5 V AA Batteries
  • Instruction Manual
  • Meter Quality Certificate
  • Probe Quality Certificate
  • Cap Quality Certificate
  • USB Type A to C Cable
  • Carrying Case

Ask a question about Hanna HI 98198 Optical Dissolved Oxygen Meter Kit

Customer Reviews for the Hanna HI 98198

Hanna HI 98198 Offers



The Hanna HI 98198 Optical Dissolved Oxygen Meter Kit produces readings you can rely on. It's made from highly durable materials and advanced technologies to provide you with long-lasting accuracy. It can even log up to 4,000 individual readings. Plus, the DO meter comes with a probe and various accessories and solutions.

Features

  • Measures the concentration of dissolved oxygen in water
  • Requires no membranes, no filling solution and no warm-up time
  • Optical DO technology ensures stable, accurate readings
  • IP67-rated body is rugged and waterproof
  • GLP data: date, time, pressure, calibrated value, temperature and salinity value of the last calibration
  • Data logging function can save up to 4,000 readings
  • USB-C port makes transferring data easy
  • Probe is made with an IP68-rated ABS body and stainless-steel guard to resist water and dust
  • Smart Cap™ technology with built-in RFID reader
  • Includes assortment of accessories and solutions
  • Automatic shutoff modes: 5, 10, 30 and 60 minutes or disabled
  • Applications Saltwater, Freshwater

Hanna HI 98198 Specifications


DO Range0 to 50 mg/L, 0 to 500% saturation
DO Resolution0.01 mg/L, 0.1% saturation
DO Accuracy1.5% of reading ±0.01mg/L for 0 to 20 mg/L; 5% of reading for 20 to 50 mg/L; 1.5% of reading ±0.1% for 0 to 200%; 5% of reading for 200 to 500%
DO CalibrationManual or automatic (1 or 2 points)
DO Temperature CompensationAutomatic from 23 to 122°F (-5 to 50°C)
Barometric Pressure CompensationSingle point anywhere within pressure range
Salinity CompensationAutomatic from 0 to 70 PSU (manually set)
Altitude CompensationAutomatic from 420 to 850 mmHg
Temperature Range23 to 122°F (-5 to 50°C)
Temperature Resolution0.1°
Temperature Accuracy±0.4°F (±0.3°C)
DisplayBacklit LCD
AutoEndYes
Battery Life~200 hours of continuous use without backlight; ~50 hours with backlight
Environment32 to 122°F (0 to 50°C); 100% RH max
Product Length7.3" (185 mm); 13' (4 m) probe cable
Product Width3.6" (93 mm)
Product Height1.4" (35.2 mm)
Product Weight15.9 oz (450 g)
Manufacturer Warranty2 years meter and probe; 1 year Smart Cap™

What's included with the Hanna HI 98198


  • Meter
  • HI 764113 Probe
  • Smart Cap™ with O-Ring
  • Bicomponent Zero Oxygen Solution
  • Calibration/Storage Vessel
  • 2 x Plastic Beakers
  • Syringe with Silicone Grease
  • Lens Wipe
  • 4 x 1.5 V AA Batteries
  • Instruction Manual
  • Meter Quality Certificate
  • Probe Quality Certificate
  • Cap Quality Certificate
  • USB Type A to C Cable
  • Carrying Case

Ask a question about Hanna HI 98198 Optical Dissolved Oxygen Meter Kit

Customer Reviews for the Hanna HI 98198

More Hanna Products