Conduct your water quality testing with this 5-in-1 photometer. It measures pH, alkalinity, free chlorine, total chlorine and cyanuric acid.
Conduct your water quality testing with this 5-in-1 photometer. It measures pH, alkalinity, free chlorine, total chlorine and cyanuric acid.
The Hanna HI 97104 pH/Alkalinity/Chlorine/Cyanuric Acid Photometer is a 5-in-1 device commonly used for a range of different applications. From drinking water to swimming pool water, this meter makes it easy to test your samples. It's durably built to withstand drops and shocks, and it features a backlit LCD to help you see the readings clearly in any conditions.
Features
Display | 128 x 64 backlit LCD |
Bandpass Filter Bandwidth | 8 nm |
Bandpass Filter Wavelength Accuracy | ±1 nm |
Light Detector | Silicon photocell |
Cuvette Type | Round, 1" (24.6 mm) diameter |
pH | 6.5 to 8.5 pH range; 0.1 pH resolution; ±0.1 pH at 77°F (25°C) accuracy |
pH Method | Adaptation of phenol red method |
Chlorine | 0 to 5 mg/L (ppm) range; 0.01 mg/L resolution; ±0.03 mg/L (ppm) ±3% of reading accuracy |
Chlorine Method | Adaptation of US EPA method 330.5, DPD Colorimetric method |
Cyanuric Acid | 0 to 80 mg/L (ppm) range; 1 mg/L resolution; ±1 mg/L ±15% of reading |
Cyanuric Acid Method | Adaptation of the turbidimetric method |
Environment | 32 to 122°F (0 to 50°C); 0 to 100% RH, non-serviceable |
Battery Life | 800+ measurements |
Product Length | 5.6" (142.5 mm) |
Product Width | 4" (102.5 mm) |
Product Height | 2" (50.5 mm) |
Product Weight | 13.4 oz (380 g) |
Manufacturer Warranty | 2 years |
Display | 128 x 64 backlit LCD |
Bandpass Filter Bandwidth | 8 nm |
Bandpass Filter Wavelength Accuracy | ±1 nm |
Light Detector | Silicon photocell |
Cuvette Type | Round, 1" (24.6 mm) diameter |
pH | 6.5 to 8.5 pH range; 0.1 pH resolution; ±0.1 pH at 77°F (25°C) accuracy |
pH Method | Adaptation of phenol red method |
Chlorine | 0 to 5 mg/L (ppm) range; 0.01 mg/L resolution; ±0.03 mg/L (ppm) ±3% of reading accuracy |
Chlorine Method | Adaptation of US EPA method 330.5, DPD Colorimetric method |
Cyanuric Acid | 0 to 80 mg/L (ppm) range; 1 mg/L resolution; ±1 mg/L ±15% of reading |
Cyanuric Acid Method | Adaptation of the turbidimetric method |
Environment | 32 to 122°F (0 to 50°C); 0 to 100% RH, non-serviceable |
Battery Life | 800+ measurements |
Product Length | 5.6" (142.5 mm) |
Product Width | 4" (102.5 mm) |
Product Height | 2" (50.5 mm) |
Product Weight | 13.4 oz (380 g) |