This high precision luminance meter for distance measurement with an acceptance angle of 1° is assigned to class B in accordance with DIN 5032-7, appendix B of IEC 13032-1 and CIE 69. It measures the perceived brightness of back-lighted surfaces in candelas per square meter (cd/m2) or foot-lamberts (fL) in consideration of ambient light.
This high precision luminance meter for distance measurement with an acceptance angle of 1° is assigned to class B in accordance with DIN 5032-7, appendix B of IEC 13032-1 and CIE 69. It measures the perceived brightness of back-lighted surfaces in candelas per square meter (cd/m2) or foot-lamberts (fL) in consideration of ambient light.
This high precision luminance meter for distance measurement with an acceptance angle of 1° is assigned to class B in accordance with DIN 5032-7, appendix B of IEC 13032-1 and CIE 69. It measures the perceived brightness of back-lighted surfaces in candelas per square meter (cd/m²) or foot-lamberts (fL) in consideration of ambient light.
MAVO-SPOT 2 USB Is equipped with an excellent adaptation to the spectral brightness sensitivity of the human eye and is highly precise with a minimal deviation of just f1' < 3 %, which is significantly better than specified in the standard. By means of the mirror reflex optics, the measuring subject may be targeted precisely in a 15° field of view and a sharply marked 1° measuring circle in the center of the viewfinder. Focus can be set for distances ranging from 1 meter to infinity. Shorter distances as of 34cm are made possible by means of optional close-up lenses. Alternatively, contact measurement can also be performed with an optional, top quality probe. The velvety coating on the adapter disc prevents scratching of self-luminous and back-lighted surfaces. Measurement functions are selected and measurements are started with convenient on-hand operation.
The display on the viewfinder is activated along with back-light by simply pressing a key. The comparative and ratio measurements are especially advantageous, by means of which deviation of measured value B from reference value A is evaluated and displayed. The relationship A/B is used for contrast measurement at workstations. Percentage deviation %A allows for an assessment of the consistency of monitor screens and projection screen lighting, and difference A-B is used to detect deviation during the production process.
Features
Applications
Ideal for the following applications: Monitors, TV Screens, Light Boxes, Light Panels, Traffic Signals, Accent Lighting, Medical Offices, Tunnel Lighting.
Illuminance | 0.1 to 99,900lx |
Back-Light | Yes |
Measured Value Memory | 1000 measured values or 10 groups of 100 measured values |
Measuring Method | Distance measurement, Contact measurement with optional luminance attachment |
Click on a category to view a selection of compatible accessories with the Gossen Photo M508G Mavo-Spot 2 USB Luminance 1° Spot Measurement Instrument.
Illuminance | 0.1 to 99,900lx |
Back-Light | Yes |
Measured Value Memory | 1000 measured values or 10 groups of 100 measured values |
Measuring Method | Distance measurement, Contact measurement with optional luminance attachment |
Click on a category to view a selection of compatible accessories with the Gossen Photo M508G Mavo-Spot 2 USB Luminance 1° Spot Measurement Instrument.