Work with this universal TRMS multimeter that features voltage, resistance, current, and temperature measuring ranges, including additional measuring and automatic functions. With universal auto-ranging, this multimeter is suitable for all areas of electrical engineering.
Work with this universal TRMS multimeter that features voltage, resistance, current, and temperature measuring ranges, including additional measuring and automatic functions. With universal auto-ranging, this multimeter is suitable for all areas of electrical engineering.
Features
Automatic blocking sockets (ABS)
Automatic blocking sockets prevent incorrect connection of measurement cables and inadvertent selection of the wrong measured quantity. This significantly reduces the danger to the user, the instrument, and the system under test, and eliminates it in many cases.
Automatic/manual measuring range selection
Measured quantities are selected with the rotary switch. The measuring range is automatically matched to measured values. The measuring range can be selected manually as well with the help of the AUTO/MAN key.
Display of negative values at the analog scale
Negative values are also displayed at the analog scale for zero frequency quantities, allowing for observation of measured quantity fluctuation around the zero-point.
Storage of measured values
By pressing the HOLD/MIN/MAX key, the currently displayed measurement value can be "frozen" in the display. The minimum and maximum values which were present at the input of the measuring instrument after activation of the MIN/MAX mode can be selectively "retained" with the MIN/ MAX function. The most important application is the determination of the minimum or maximum value during long-term observation of measurement quantities. MIN/MAX does not affect the analog display; it continues to display the current measurement value.
Continuity test
Allows for the detection of short-circuits and interrupted conductors. In addition to displaying test results, an acoustic signal can also be generated if desired.
Power saving circuit
The device is switched off automatically if the measured value remains unchanged for approximately 10 minutes, and if none of the controls are activated during this time. The automatic shutdown can be deactivated.
Protective cover for harsh conditions
The instrument is protected against damage in the event of impacts or dropping using a soft rubber cover with a tilt stand. The rubber material also assures that the instrument does not wander if it is set up on a vibrating surface.
RMS measurement with distorted waveshapes
The measuring method applied allows for RMS measurement for alternating signals (AC) in voltage and current measurement, independent of the waveshape up to 1 kHz (for non-sinusoidal signals as well).
Applications
Analog | |
Display | LCD scale with pointer Polarity: With automatic switching Overflow: Triangle |
Scaling | 0 to 60 with 61 scale divisions in all ranges |
Scale Length | 2.17" (55 mm) in all ranges |
Measuring Rate | 20 measurements per second | General Specification |
Measuring Function V | Range: 600 mV, 6, 60, 600 v Resolution: 100 μV, 1, 10, 100 mV |
Measuring Function A | Range: 60, 600 mA, 6, 10 A Resolution: 10, 100 μA, 1, 10 mA |
Measuring Function Ω | Range: 600 Ω, 6, 60, 600 kΩ, 6, 40 MΩ Resolution: 100 mΩ, 1, 10, 100 Ω, 1, 10 kΩ, 1 mV |
Interference | Emission: EN 61326-1: 2013 class B Immunity: EN 61326-1: 2013, EN 61326-1-2: 2013 |
Fuse Links for All Ranges | Up to 600 mA: FF 1.6 A/1000 V, 0.24 x 1.26" (6.3 mm x 32 mm), switching capacity: 10 kA at 1000 V~ with ohmic load, protects all current measuring ranges up to 600 mA in combination with power diodes Up to 10 A: FF 10 A/1000 V, 0.39 x 1.50" (10 mm x 38 mm), switching capacity: 30 kA at 1000 V with ohmic load, protects 6 and 10 A ranges to 1000 V |
Accuracy Range | 32 to 104°F (0 to 40°C) |
Display | LCD panel 2.56 x 1.18" (65 x 30 mm) with analog and digital display including unit of measure, type of current and various special functions. Background illumination the ON / OFF key, and is switched off automatically after approximately 1 |
Measured Quantity | Frequency: 45 to 65 Hz Waveshape: Sinusoidal |
Scaling | 0 to 60 with 61 scale divisions in all ranges |
Scale Length | 2.16" (55 mm), in all ranges |
Nominal Voltage | 600 V |
Pollution Degree | 2 |
Temperature | Operating: 14 to 122°F (-10 to 50°C) Storage: -13 to 158°F (-25 to 70°C), without batteries Ambient: 73.4°F (23°C) ± 2 K |
Relative Humidity | 45 to 75%, no condensation allow |
Elevation | To 6561.68' (2000 m) |
Protection | IP 40, IP 20 at the connector jacks per DIN VDE 0470, part 1 / EN 60529 |
Safety Class | II per IEC 61010-1:2010/EN 61010-1:2010/VDE 0411-1:2011 |
Measuring Category | CAT III |
Battery | 2 x 1.5 V AA size batteries, alkaline manganese per IEC LR6 or equivalent rechargeable NiCd battery |
Dimensions | 3.3 x 7.68 x 1.38" (84 x 195 x 35 mm) |
Weight | Approximately 0.77 lbs (0.35 kg), with batteries |
Click on a category to view a selection of compatible accessories with the Gossen Metrawatt M205A METRAHIT 2+ Universal TRMS Multimeter with analog bar graph and temperature measuring instrument.
Analog | |
Display | LCD scale with pointer Polarity: With automatic switching Overflow: Triangle |
Scaling | 0 to 60 with 61 scale divisions in all ranges |
Scale Length | 2.17" (55 mm) in all ranges |
Measuring Rate | 20 measurements per second | General Specification |
Measuring Function V | Range: 600 mV, 6, 60, 600 v Resolution: 100 μV, 1, 10, 100 mV |
Measuring Function A | Range: 60, 600 mA, 6, 10 A Resolution: 10, 100 μA, 1, 10 mA |
Measuring Function Ω | Range: 600 Ω, 6, 60, 600 kΩ, 6, 40 MΩ Resolution: 100 mΩ, 1, 10, 100 Ω, 1, 10 kΩ, 1 mV |
Interference | Emission: EN 61326-1: 2013 class B Immunity: EN 61326-1: 2013, EN 61326-1-2: 2013 |
Fuse Links for All Ranges | Up to 600 mA: FF 1.6 A/1000 V, 0.24 x 1.26" (6.3 mm x 32 mm), switching capacity: 10 kA at 1000 V~ with ohmic load, protects all current measuring ranges up to 600 mA in combination with power diodes Up to 10 A: FF 10 A/1000 V, 0.39 x 1.50" (10 mm x 38 mm), switching capacity: 30 kA at 1000 V with ohmic load, protects 6 and 10 A ranges to 1000 V |
Accuracy Range | 32 to 104°F (0 to 40°C) |
Display | LCD panel 2.56 x 1.18" (65 x 30 mm) with analog and digital display including unit of measure, type of current and various special functions. Background illumination the ON / OFF key, and is switched off automatically after approximately 1 |
Measured Quantity | Frequency: 45 to 65 Hz Waveshape: Sinusoidal |
Scaling | 0 to 60 with 61 scale divisions in all ranges |
Scale Length | 2.16" (55 mm), in all ranges |
Nominal Voltage | 600 V |
Pollution Degree | 2 |
Temperature | Operating: 14 to 122°F (-10 to 50°C) Storage: -13 to 158°F (-25 to 70°C), without batteries Ambient: 73.4°F (23°C) ± 2 K |
Relative Humidity | 45 to 75%, no condensation allow |
Elevation | To 6561.68' (2000 m) |
Protection | IP 40, IP 20 at the connector jacks per DIN VDE 0470, part 1 / EN 60529 |
Safety Class | II per IEC 61010-1:2010/EN 61010-1:2010/VDE 0411-1:2011 |
Measuring Category | CAT III |
Battery | 2 x 1.5 V AA size batteries, alkaline manganese per IEC LR6 or equivalent rechargeable NiCd battery |
Dimensions | 3.3 x 7.68 x 1.38" (84 x 195 x 35 mm) |
Weight | Approximately 0.77 lbs (0.35 kg), with batteries |
Click on a category to view a selection of compatible accessories with the Gossen Metrawatt M205A METRAHIT 2+ Universal TRMS Multimeter with analog bar graph and temperature measuring instrument.