The cable fault finder with BNC to alligator clips is easy-to-use. It comes with a cable fault locator, a cable and wire manager and a tone generator with SmartTone technology. It finds the distance to opens or shorts on electrical wire, telephone wire, security wire and coax.
The cable fault finder with BNC to alligator clips is easy-to-use. It comes with a cable fault locator, a cable and wire manager and a tone generator with SmartTone technology. It finds the distance to opens or shorts on electrical wire, telephone wire, security wire and coax.
Features
Power | 4 AA alkaline batteries, provide 50 hours |
Reverse Battery Protection | No damage to the tester will occur if the batteries are installed backwards |
Input Protection | 250 V rms ac, continuous or intermittent |
Impedance Range | 35 to 330 Ω with auto-compensation within this range. Cables with an impedance outside this range will not be properly tested and may produce erratic or incorrect readings |
Maximum Length | 2500 feet on most cable types, and 500 feet on very lossy cables. The tester will feet on very lossy cables. The tester will display "Err" if the cable is too long to be correctly measured |
Minimum Length | No minimum length Minimum non-zero reading is 2 feet |
Temperature Range Operating Storage | 32 to 131°F (0 to 55°C) -40 to 158°F (-40 to 70°C) |
Humidity Operating Storage | 0 to 80%, 0 to 100% |
Weight | 1 lbs with batteries and clip leads |
Operating Altitude | 10,000 ft max |
Certifications and Compliance | Conformité Européenne. Conforms to relevant European Union directives. CAN/CSA-C22.2 No. 60950-1-03 CAN/CSA-C22.2 No. 1010.1-92 CSA-C22.2 No. 1010.1B-97, UL/ANSI 3111-1 |
Power | 4 AA alkaline batteries, provide 50 hours |
Reverse Battery Protection | No damage to the tester will occur if the batteries are installed backwards |
Input Protection | 250 V rms ac, continuous or intermittent |
Impedance Range | 35 to 330 Ω with auto-compensation within this range. Cables with an impedance outside this range will not be properly tested and may produce erratic or incorrect readings |
Maximum Length | 2500 feet on most cable types, and 500 feet on very lossy cables. The tester will feet on very lossy cables. The tester will display "Err" if the cable is too long to be correctly measured |
Minimum Length | No minimum length Minimum non-zero reading is 2 feet |
Temperature Range Operating Storage | 32 to 131°F (0 to 55°C) -40 to 158°F (-40 to 70°C) |
Humidity Operating Storage | 0 to 80%, 0 to 100% |
Weight | 1 lbs with batteries and clip leads |
Operating Altitude | 10,000 ft max |
Certifications and Compliance | Conformité Européenne. Conforms to relevant European Union directives. CAN/CSA-C22.2 No. 60950-1-03 CAN/CSA-C22.2 No. 1010.1-92 CSA-C22.2 No. 1010.1B-97, UL/ANSI 3111-1 |