Ideal for partial discharge detection, pressurized leak detection, and mechanical fault detection, this industrial acoustic imaging camera detects mechanical faults for early identification of bearing problems. In addition, this camera quantifies the leak rate and cost of industrial gas and compressed air leaks.
Ideal for partial discharge detection, pressurized leak detection, and mechanical fault detection, this industrial acoustic imaging camera detects mechanical faults for early identification of bearing problems. In addition, this camera quantifies the leak rate and cost of industrial gas and compressed air leaks.
Work with on-camera and in-software severity assessment and type classification of partial discharge (PD) issues with this acoustic imaging camera. In addition, this camera features automatic frequency tuning, 8x zoom, 12 MP, GPS data integration, an IP54 rating, and a QR code reader.
Features
On-camera PD severity assessment speeds up decisions
Applications
Detection Threshold | 20 kHz: -7 dB SPL 35 kHz: 4 dB SPL 50 kHz: 10 dB SPL 80 kHz: 36 dB SPL 100 kHz: 51 dB SPL |
Bandwidth | 2 to 130 kHz |
Directional Resolution | From 1° up to 0.125° |
Operating Distance | From 1' (0.3 m) up to 656' (200 m) |
Severity Assessment | Automatic AI-based severity assessment including recommended actions onboard camera |
Leak Localization and Detection | Automatic leak recognition including estimated leak size and annual cost |
Leak Rate Detection Threshold | 0.0032 l/min from 2.5 m, 0.0044 l/min from 6 m |
Supported Gases | Compressed air, hydrogen, CO2, methane, natural gas, helium, argon, ammonia |
Other Acoustic Analysis Modes | Mechanical fault detection |
Digital Camera | 12 MP color |
Camera Field of View | 75° diagonal |
Video Frame Rate | Camera: 60 fps Acoustic image: 30 fps Screen: 70 fps |
Zoom | 8x digital zoom |
Video Image Resolution | 1280 × 720 |
Display | Size: 5" (127 mm), 1280 x 720 Resistive touch screen, TFT LCD, MIPI DSI |
Integrated Flashlight | LEDs, three modes off, normal and bright |
Analysis and Reporting | Online: FLIR Acoustic Camera Viewer (cloud service) Offline: FLIR Thermal Studio (desktop software) |
Communication and Data Storage | Data transfer: Wi-Fi 2.4 and 5 GHz IEEE 802.11.b/g/n/ac wireless LAN USB memory stick Camera software update: Automatic Over The Air (OTA) wireless update or via USB connection Still image format: .nlz and .jpg Video recording and format: Up to 5 minutes (.nlz format) Storage, internal: 128 GB (SD card) Storage, external: USB 8 GB, Cloud storage capacity is unlimited Image annotations: GPS, image tags and comments connection |
Power Supply | Camera power input: Nominal input voltage: 12 V DC Maximum input: 17 V DC, 3.3 A (limited) Battery: Li-Ion rechargeable battery pack (RRC 2054): 14.4 V DC, 3.45 Ah, 49.68 Wh Usage: Up to 2.5 hours (depends on ambient conditions and usage, needs to be retested and confirmed with final product) Charge time: Approximately 2 hours Maximum output: 16.8 V DC, 5 A Battery charger: Input: 19 to 26 V DC, 2.8 A Maximum output: 17.4 V DC, 4.8 A |
Environmental Data | Operating temperature range: 14 to 122°F (-10 to 50°C) Storage temperature range: -4 to 122°F (-20 to 50°C) maximum 4 to 77°F (-20 to 25°C) recommended (determined by the battery) Relative humidity: 0 to 90% recommended EMC: CFR47 FCC part 15 subpart B Radio: CFR47 FCC part 15 subpart C/E, ETSI EN 301 489-1/-17/-19, ETSI EN 300 328, ETSI EN 301 893 Protection class: IP54 Safety: IEC 62368-1 |
Dimensions | Camera: 11 x 7 x 6" (288 x 182 x 159 mm) Battery: 3.3 x 3.03" (85 x 77 mm), RRC2504 Packaging: 19.3 × 14.4 × 7.5" (490 x 365 x 190 mm) |
Weight | Camera: 2.64 lbs (1.2 kg) Battery: 0.55 lbs (0.25 kg) Camera + battery: 3.2 lbs (1.45 kg) Packaging: 13 lbs (6 kg) |
Click on a category to view a selection of compatible accessories with the FLIR Si2-Pro Industrial Acoustic Imaging Camera for partial discharge detection/pressurized leak detection/mechanical fault detection, 2 to 130 kHz, 1280 × 720.
Detection Threshold | 20 kHz: -7 dB SPL 35 kHz: 4 dB SPL 50 kHz: 10 dB SPL 80 kHz: 36 dB SPL 100 kHz: 51 dB SPL |
Bandwidth | 2 to 130 kHz |
Directional Resolution | From 1° up to 0.125° |
Operating Distance | From 1' (0.3 m) up to 656' (200 m) |
Severity Assessment | Automatic AI-based severity assessment including recommended actions onboard camera |
Leak Localization and Detection | Automatic leak recognition including estimated leak size and annual cost |
Leak Rate Detection Threshold | 0.0032 l/min from 2.5 m, 0.0044 l/min from 6 m |
Supported Gases | Compressed air, hydrogen, CO2, methane, natural gas, helium, argon, ammonia |
Other Acoustic Analysis Modes | Mechanical fault detection |
Digital Camera | 12 MP color |
Camera Field of View | 75° diagonal |
Video Frame Rate | Camera: 60 fps Acoustic image: 30 fps Screen: 70 fps |
Zoom | 8x digital zoom |
Video Image Resolution | 1280 × 720 |
Display | Size: 5" (127 mm), 1280 x 720 Resistive touch screen, TFT LCD, MIPI DSI |
Integrated Flashlight | LEDs, three modes off, normal and bright |
Analysis and Reporting | Online: FLIR Acoustic Camera Viewer (cloud service) Offline: FLIR Thermal Studio (desktop software) |
Communication and Data Storage | Data transfer: Wi-Fi 2.4 and 5 GHz IEEE 802.11.b/g/n/ac wireless LAN USB memory stick Camera software update: Automatic Over The Air (OTA) wireless update or via USB connection Still image format: .nlz and .jpg Video recording and format: Up to 5 minutes (.nlz format) Storage, internal: 128 GB (SD card) Storage, external: USB 8 GB, Cloud storage capacity is unlimited Image annotations: GPS, image tags and comments connection |
Power Supply | Camera power input: Nominal input voltage: 12 V DC Maximum input: 17 V DC, 3.3 A (limited) Battery: Li-Ion rechargeable battery pack (RRC 2054): 14.4 V DC, 3.45 Ah, 49.68 Wh Usage: Up to 2.5 hours (depends on ambient conditions and usage, needs to be retested and confirmed with final product) Charge time: Approximately 2 hours Maximum output: 16.8 V DC, 5 A Battery charger: Input: 19 to 26 V DC, 2.8 A Maximum output: 17.4 V DC, 4.8 A |
Environmental Data | Operating temperature range: 14 to 122°F (-10 to 50°C) Storage temperature range: -4 to 122°F (-20 to 50°C) maximum 4 to 77°F (-20 to 25°C) recommended (determined by the battery) Relative humidity: 0 to 90% recommended EMC: CFR47 FCC part 15 subpart B Radio: CFR47 FCC part 15 subpart C/E, ETSI EN 301 489-1/-17/-19, ETSI EN 300 328, ETSI EN 301 893 Protection class: IP54 Safety: IEC 62368-1 |
Dimensions | Camera: 11 x 7 x 6" (288 x 182 x 159 mm) Battery: 3.3 x 3.03" (85 x 77 mm), RRC2504 Packaging: 19.3 × 14.4 × 7.5" (490 x 365 x 190 mm) |
Weight | Camera: 2.64 lbs (1.2 kg) Battery: 0.55 lbs (0.25 kg) Camera + battery: 3.2 lbs (1.45 kg) Packaging: 13 lbs (6 kg) |
Click on a category to view a selection of compatible accessories with the FLIR Si2-Pro Industrial Acoustic Imaging Camera for partial discharge detection/pressurized leak detection/mechanical fault detection, 2 to 130 kHz, 1280 × 720.