The SmartLog Pro with motorized turnstile controls access to ESD protected area to operators that have passed their pre-defined ESD tests and have been granted access to the area.
The SmartLog Pro with motorized turnstile controls access to ESD protected area to operators that have passed their pre-defined ESD tests and have been granted access to the area.
Features
SmartLog Pro® Input Voltage and Frequency (External Adapter) |
AC/DC Power Adapter Power input: 100 to 240 VAC, 50/60 Hz Power output: 5 VDC, 3.0 A Cable length: 5' (1.5 m) |
Turnstile Input Voltage and Frequency | 100 to 120 VAC, 50/60 Hz |
Operating Temperature | 70 to 85°F (21 to 30°C) for 1 GΩ test limit 41 to 85°F (5 to 30°C) for all other test limits |
Environmental Requirements | Indoor use only at altitudes less than 6500' (2 km) Maximum relative humidity of 80% up to 85°F (30°C) decreasing linearly to 50% at 85°F (30°C) Maximum relative humidity of 50% at 1 GΩ setting |
Test Switch Voltage | 5 VDC at open circuit |
Wrist Strap and Footwear Test Voltage | 30 VDC at open circuit Test current is limited by resistors and varies on the test range setting (100 kΩ to 1 GΩ) |
Test Accuracy | ±20% for 1 GΩ footwear test limit ±10% for all other test limits |
Dimensions | Turnstile: 44 x 50 x 60" (112 x 127 x 152 cm) Dual independent foot plate: 14 x 16 x 0.9" (35.6 x 40.1 x 2.3 cm) |
Weight | Turnstile: 400 lbs (181 kg) Dual independent foot plate: 7.5 lbs (3.4 kg) |
SmartLog Pro® Input Voltage and Frequency (External Adapter) |
AC/DC Power Adapter Power input: 100 to 240 VAC, 50/60 Hz Power output: 5 VDC, 3.0 A Cable length: 5' (1.5 m) |
Turnstile Input Voltage and Frequency | 100 to 120 VAC, 50/60 Hz |
Operating Temperature | 70 to 85°F (21 to 30°C) for 1 GΩ test limit 41 to 85°F (5 to 30°C) for all other test limits |
Environmental Requirements | Indoor use only at altitudes less than 6500' (2 km) Maximum relative humidity of 80% up to 85°F (30°C) decreasing linearly to 50% at 85°F (30°C) Maximum relative humidity of 50% at 1 GΩ setting |
Test Switch Voltage | 5 VDC at open circuit |
Wrist Strap and Footwear Test Voltage | 30 VDC at open circuit Test current is limited by resistors and varies on the test range setting (100 kΩ to 1 GΩ) |
Test Accuracy | ±20% for 1 GΩ footwear test limit ±10% for all other test limits |
Dimensions | Turnstile: 44 x 50 x 60" (112 x 127 x 152 cm) Dual independent foot plate: 14 x 16 x 0.9" (35.6 x 40.1 x 2.3 cm) |
Weight | Turnstile: 400 lbs (181 kg) Dual independent foot plate: 7.5 lbs (3.4 kg) |