Powerful and economical, this panel meter is the ideal solution for large-scale deployment within an electrical distribution system. In addition, this meter is certified ANSI C12.20 0.2 accuracy class and IEC 62053-22 0.2S energy measurements.
Powerful and economical, this panel meter is the ideal solution for large-scale deployment within an electrical distribution system. In addition, this meter is certified ANSI C12.20 0.2 accuracy class and IEC 62053-22 0.2S energy measurements.
Discontinued!
This product has been discontinued and is no longer available. There is no direct replacement. Don't worry, we have some options to help you find what you need:
Visit our Plug-In Power Meters category for similar products.
Or let's do a search and help you find what you need:
Features
*Depending on model configuration.
Applications
Isolation | All inputs and outputs are galvanically isolated to 2500 V AC |
Sensing Method | RMS Sampling at 400+ samples per cycle on all channels measured readings simultaneously |
Environmental Rating | Storage/Operating: -4 to 158°F (-20 to 70°C) Humidity: To 95% RH non-condensing Faceplate rating: NEMA 12 (water-resistant) gasket included Protection: IP30 - meter front/back |
Compliance | ANSI C12.20 0.2 Accuracy Class and C12.1 (MET Labs Certified) ANSI C62.41 (Burst) FCC, Part 15, Subpart B, Class A (Radiated and Conducted Emissions) IEC 62053-22 Accuracy, 0.2S (KEMA Laboratories Certified) IEC 62053-23 Edition 1, Class 2 EN 61000-6-2 - Immunity for Industrial Environments: 2005 EN 61000-6-4 - Emission Standards for Industrial Environments: 2007 CE (EN 61326-1, EN 61000-6-2, EN 61000-6-4) EN 61000-3-2, Class A (Harmonic Current) EN 61000-3-3 (Voltage Fluctuation and Flicker) IEC 61000-4-2, Ed.1.2, Class A (Electrostatic Discharge) IEC 61000-4-3, Class A (Radiated EM Immunity) IEC 61000-4-4, Second Ed., Class A (EFT) IEC 61000-4-5, Ed. 1.1, Class A (Surge Immunity) IEC 61000-4-6 (Conducted Immunity) IEC 61000-4-8, Class A (Magnetic Immunity) IEC 61000-4-11, Class A (Voltage Variations Immunity) IEC/CISPR11, Ed.4.1 (Radiated Emissions) CISPR22, Class A, Fifth Ed. IEC 61850 (KEMA Laboratories Certified) IEEE C37.90.1 (Surge Withstand Capability) Certified to UL/IEC 61010-1 and CSA C22.2 No. 61010-1, UL File: E250818 REACH/RoHS 3 Directive 2011/65/EU New York State approved for residential metering |
Dimensions | 4.85 x 4.85 x 4.25" (123.2 x 123.2 x 108 mm) |
Weight | 2 lbs (0.91 kg) |
Isolation | All inputs and outputs are galvanically isolated to 2500 V AC |
Sensing Method | RMS Sampling at 400+ samples per cycle on all channels measured readings simultaneously |
Environmental Rating | Storage/Operating: -4 to 158°F (-20 to 70°C) Humidity: To 95% RH non-condensing Faceplate rating: NEMA 12 (water-resistant) gasket included Protection: IP30 - meter front/back |
Compliance | ANSI C12.20 0.2 Accuracy Class and C12.1 (MET Labs Certified) ANSI C62.41 (Burst) FCC, Part 15, Subpart B, Class A (Radiated and Conducted Emissions) IEC 62053-22 Accuracy, 0.2S (KEMA Laboratories Certified) IEC 62053-23 Edition 1, Class 2 EN 61000-6-2 - Immunity for Industrial Environments: 2005 EN 61000-6-4 - Emission Standards for Industrial Environments: 2007 CE (EN 61326-1, EN 61000-6-2, EN 61000-6-4) EN 61000-3-2, Class A (Harmonic Current) EN 61000-3-3 (Voltage Fluctuation and Flicker) IEC 61000-4-2, Ed.1.2, Class A (Electrostatic Discharge) IEC 61000-4-3, Class A (Radiated EM Immunity) IEC 61000-4-4, Second Ed., Class A (EFT) IEC 61000-4-5, Ed. 1.1, Class A (Surge Immunity) IEC 61000-4-6 (Conducted Immunity) IEC 61000-4-8, Class A (Magnetic Immunity) IEC 61000-4-11, Class A (Voltage Variations Immunity) IEC/CISPR11, Ed.4.1 (Radiated Emissions) CISPR22, Class A, Fifth Ed. IEC 61850 (KEMA Laboratories Certified) IEEE C37.90.1 (Surge Withstand Capability) Certified to UL/IEC 61010-1 and CSA C22.2 No. 61010-1, UL File: E250818 REACH/RoHS 3 Directive 2011/65/EU New York State approved for residential metering |
Dimensions | 4.85 x 4.85 x 4.25" (123.2 x 123.2 x 108 mm) |
Weight | 2 lbs (0.91 kg) |