FREE SHIPPING ON ONLINE ORDERS OVER $99*

Dwyer DHC-006 Digihelic Differential Pressure Controller (0-2.5"w.c.)

Model: DHC-006

Dwyer DHC-006 Digihelic Differential Pressure Controller (0-2.5"w.c.)

Model: DHC-006

3 in 1 instrument possessing a digital display gage, control relay switches, and a transmitter with current output all packed in the popular Photohelic® gage style housing. Ideal for pressure, velocity and flow applications, achieving a 1% full scale accuracy on ranges down to the extremely low 0.25" w.c. to 2.5" w.c. full scale.

3 in 1 instrument possessing a digital display gage, control relay switches, and a transmitter with current output all packed in the popular Photohelic® gage style housing. Ideal for pressure, velocity and flow applications, achieving a 1% full scale accuracy on ranges down to the extremely low 0.25" w.c. to 2.5" w.c. full scale.

Sale Price $736.56 CAD
Regular Price $792.00 CAD
Availability 1 to 2 Weeks
Quantity

Dwyer DH3-005 Digital Pressure Panel Meter

  • Type: Pressure
  • Item: Digital Panel Meter
  • Input Range: 0 to 2.5" WC
  • Display Span: 9999
  • Display Digits: Selectable
  • Display: 4 Digit LCD
  • Relays: 2 SPDT
  • Fits: 4-1/2" Round Cut Out
  • Connector Type: Compression Fitting
  • Process Connection: 1/8" ID Tubing
  • Power Required: 12 to 28VDC, 12 to 28 VAC
  • Output: 4 to 20mA DC
  • Depth: 3-1/8
  • Mounting: Front Ring

Dwyer DHC-006 Specifications

Switch Specifications
Switch Type 2 SPDT relays
Electrical Rating 1 A at 30 VAC/VDC
Set Point Adjustment Adjustable via keypad on face
General Specifications
Service Air and non-combustible, compatible gases
Wetted Materials Consult factory
Housing Material Die cast aluminum case and bezel
Accuracy ±1.5% for 0.25" and ±0.25" w.c. ranges
Ranges 0.5" to 5" w.c. and corresponding bi-directional (except ±2.5" w.c.) ±1%
All other ranges: ±0.5% @ 77°F (25°C) including hysteresis and repeatability (after 1 hour warm-up)
Stability <±1% per year
Pressure Limits Ranges ≤ 2.5" w.c.: 25 psi
±2.5", 5" w.c.: 5 psi
10" w.c.: 5 psi
25" w.c.: 5 psi
50" w.c.: 5 psi
100" w.c.: 9 psi
Temperature Limits 32 to 140°F (0 to 60°C)
Compensated Temperature Limits 32 to 140°F (0 to 60°C)
Thermal Effects 0.020%/°F (0.036/°C) from 77°F (25°C)
0.25" and ±0.25" w.c. ranges: ±0.03%/°F (±0.054%/°C)
Power Requirements 12 to 28 VDC
12 to 28 VAC
50 to 400 Hz
Power Consumption 3 VA max
Output Signal 4 to 20 mA DC into 900 Ω max
Zero and Span Adjustments Accessible via menus
Response Time 250 ms (damping set to 1)
Display Backlit 4 digit LCD 0.4" height LED indicators for set point and alarm status
Electrical Connections 15 pin male high density D-sub connection. 18" (46 cm) cable with 10 conductors included
Process Connections ⅛" female NPT. Side or back connections
Mounting Orientation Mount unit in vertical plane
Dimensions 5 x 318" (127 x 79.38 mm)
Weight 1.75 lb (794 g)
Agency Approvals CE
Click here for complete specifications on the Dwyer DHC-006

What's included with the Dwyer DHC-006

  • Dwyer DHC-006 Digihelic Differential Pressure Controller (0-2.5"w.c.)

Click on a category to view a selection of compatible accessories with the Dwyer DHC-006 Digihelic Differential Pressure Controller (0-2.5"w.c.).


Dwyer A-370 Flush Mounting Bracket for Capsuhelic Gauges A-370
Bracket is surface mounted. Steel with gray hammertone epoxy finish.




Ask a question about Dwyer DHC-006 Digihelic Differential Pressure Controller (0-2.5"w.c.)

Customer Reviews for the Dwyer DHC-006

Dwyer DH3-005 Digital Pressure Panel Meter

  • Type: Pressure
  • Item: Digital Panel Meter
  • Input Range: 0 to 2.5" WC
  • Display Span: 9999
  • Display Digits: Selectable
  • Display: 4 Digit LCD
  • Relays: 2 SPDT
  • Fits: 4-1/2" Round Cut Out
  • Connector Type: Compression Fitting
  • Process Connection: 1/8" ID Tubing
  • Power Required: 12 to 28VDC, 12 to 28 VAC
  • Output: 4 to 20mA DC
  • Depth: 3-1/8
  • Mounting: Front Ring

Dwyer DHC-006 Specifications

Switch Specifications
Switch Type 2 SPDT relays
Electrical Rating 1 A at 30 VAC/VDC
Set Point Adjustment Adjustable via keypad on face
General Specifications
Service Air and non-combustible, compatible gases
Wetted Materials Consult factory
Housing Material Die cast aluminum case and bezel
Accuracy ±1.5% for 0.25" and ±0.25" w.c. ranges
Ranges 0.5" to 5" w.c. and corresponding bi-directional (except ±2.5" w.c.) ±1%
All other ranges: ±0.5% @ 77°F (25°C) including hysteresis and repeatability (after 1 hour warm-up)
Stability <±1% per year
Pressure Limits Ranges ≤ 2.5" w.c.: 25 psi
±2.5", 5" w.c.: 5 psi
10" w.c.: 5 psi
25" w.c.: 5 psi
50" w.c.: 5 psi
100" w.c.: 9 psi
Temperature Limits 32 to 140°F (0 to 60°C)
Compensated Temperature Limits 32 to 140°F (0 to 60°C)
Thermal Effects 0.020%/°F (0.036/°C) from 77°F (25°C)
0.25" and ±0.25" w.c. ranges: ±0.03%/°F (±0.054%/°C)
Power Requirements 12 to 28 VDC
12 to 28 VAC
50 to 400 Hz
Power Consumption 3 VA max
Output Signal 4 to 20 mA DC into 900 Ω max
Zero and Span Adjustments Accessible via menus
Response Time 250 ms (damping set to 1)
Display Backlit 4 digit LCD 0.4" height LED indicators for set point and alarm status
Electrical Connections 15 pin male high density D-sub connection. 18" (46 cm) cable with 10 conductors included
Process Connections ⅛" female NPT. Side or back connections
Mounting Orientation Mount unit in vertical plane
Dimensions 5 x 318" (127 x 79.38 mm)
Weight 1.75 lb (794 g)
Agency Approvals CE
Click here for complete specifications on the Dwyer DHC-006

What's included with the Dwyer DHC-006

  • Dwyer DHC-006 Digihelic Differential Pressure Controller (0-2.5"w.c.)

Click on a category to view a selection of compatible accessories with the Dwyer DHC-006 Digihelic Differential Pressure Controller (0-2.5"w.c.).


Dwyer A-370 Flush Mounting Bracket for Capsuhelic Gauges A-370
Bracket is surface mounted. Steel with gray hammertone epoxy finish.




Ask a question about Dwyer DHC-006 Digihelic Differential Pressure Controller (0-2.5"w.c.)

Customer Reviews for the Dwyer DHC-006

More Dwyer Products