Dwyer 641B-4 Air Velocity Transmitter, 250 to 2000 FPM

Model: 641B-4

Dwyer 641B-4 Air Velocity Transmitter, 250 to 2000 FPM

Model: 641B-4

Suitable for measuring dirty air flow through heated mass-flow sensor technology, this air velocity transmitter runs four selectable ranges from 250 to 2000 FPM. In addition, this transmitter runs with an isolated 4 to 20 mA output and a corresponding metric range of 1.25 to 10 MPS.

Suitable for measuring dirty air flow through heated mass-flow sensor technology, this air velocity transmitter runs four selectable ranges from 250 to 2000 FPM. In addition, this transmitter runs with an isolated 4 to 20 mA output and a corresponding metric range of 1.25 to 10 MPS.

Sale Price $934.65 CAD
Regular Price $1005.00 CAD
Availability 4 to 5 Weeks
Quantity

ISO Certified In-House Calibration Certificate for your Dwyer 641B-4 Air Velocity Transmitter

ISO Certified In-House Calibration Certificate for your Dwyer 641B-4 Air Velocity Transmitter

Dwyer 641B-4 Offers

Features

  • Ranges from 250 to 2000 FPM (1.25 to 10 MPS)
  • Provides and isolated 4 to 20 mA output proportional to the velocity
  • Steel sensor allows the unit to be used in dirty air environments
  • This rugged sensor is ideally suited for quick field cleaning from a simple cloth to a pulse of air from an air source
  • Proper sensor performance can be maintained in these polluted environments by easily removing dust and debris from the sensor which is problematic for pitot tubes and other flow sensing transmitters
  • Digital filter for signal dampening
  • Designed for easy and flexible connection to power and loop receivers

Applications

  • Exhaust stack flow monitoring
  • Air control in drying processes
  • HVAC/R air velocity measurements
  • Fan supply and exhaust tracking
  • Clean room ventilation monitoring

Dwyer 641B-4 Specifications

Service Air and compatible non-combustible gases from 250 to 2000 FPM (1.25 to 10 MPS)
Accuracy 5% FS process gas: 32 to 122°F (0 to 50°C)
6% FS process gas: -40 to 32°F and 122 to 176°F (-40 to 0°C and 50 to 80°C)
Response Time Flow: 1.5 seconds to 95% of final value (output filter set to minimum)
Temperature Limits Process: -40 to 176°F (-40 to 80°C)
Ambient: 32 to 140°F (0 to 60°C)
Humidity Limit Non-condensing
Power Requirements 12 to 35 V DC / 10 to 16 V AC
1.5 A rating required on supply due to initial power surge drawn by transmitter
Output Signal: 4 to 20 mA, isolated 24 V source, 3 or 4-wire connection
Filter: selectable 0.5 to 15 seconds
Loop Resistance 600 Ω
Current Consumption 300 mA maximum*
*A brief current transient exceeding 300 mA may be seen on startup.
Electrical Connections Screw-type terminal
Enclosure Rating Designed to meet NEMA 4X (IP66)
Mounting Orientation Mounting not position sensitive
Dimensions 1.72 x 9.25" (43.66 x 235 mm)
Weight 0.79 lbs (357.2 g)
Click here for complete specifications on the Dwyer 641B-4

What's included with the Dwyer 641B-4

  • Dwyer 641B-4 Air Velocity Transmitter, 250 to 2000 FPM

Click on a category to view a selection of compatible accessories with the Dwyer 641B-4 Air Velocity Transmitter, 250 to 2000 FPM.

Ask a question about Dwyer 641B-4 Air Velocity Transmitter, 250 to 2000 FPM

Customer Reviews for the Dwyer 641B-4

Dwyer 641B-4 Offers

Features

  • Ranges from 250 to 2000 FPM (1.25 to 10 MPS)
  • Provides and isolated 4 to 20 mA output proportional to the velocity
  • Steel sensor allows the unit to be used in dirty air environments
  • This rugged sensor is ideally suited for quick field cleaning from a simple cloth to a pulse of air from an air source
  • Proper sensor performance can be maintained in these polluted environments by easily removing dust and debris from the sensor which is problematic for pitot tubes and other flow sensing transmitters
  • Digital filter for signal dampening
  • Designed for easy and flexible connection to power and loop receivers

Applications

  • Exhaust stack flow monitoring
  • Air control in drying processes
  • HVAC/R air velocity measurements
  • Fan supply and exhaust tracking
  • Clean room ventilation monitoring

Dwyer 641B-4 Specifications

Service Air and compatible non-combustible gases from 250 to 2000 FPM (1.25 to 10 MPS)
Accuracy 5% FS process gas: 32 to 122°F (0 to 50°C)
6% FS process gas: -40 to 32°F and 122 to 176°F (-40 to 0°C and 50 to 80°C)
Response Time Flow: 1.5 seconds to 95% of final value (output filter set to minimum)
Temperature Limits Process: -40 to 176°F (-40 to 80°C)
Ambient: 32 to 140°F (0 to 60°C)
Humidity Limit Non-condensing
Power Requirements 12 to 35 V DC / 10 to 16 V AC
1.5 A rating required on supply due to initial power surge drawn by transmitter
Output Signal: 4 to 20 mA, isolated 24 V source, 3 or 4-wire connection
Filter: selectable 0.5 to 15 seconds
Loop Resistance 600 Ω
Current Consumption 300 mA maximum*
*A brief current transient exceeding 300 mA may be seen on startup.
Electrical Connections Screw-type terminal
Enclosure Rating Designed to meet NEMA 4X (IP66)
Mounting Orientation Mounting not position sensitive
Dimensions 1.72 x 9.25" (43.66 x 235 mm)
Weight 0.79 lbs (357.2 g)
Click here for complete specifications on the Dwyer 641B-4

What's included with the Dwyer 641B-4

  • Dwyer 641B-4 Air Velocity Transmitter, 250 to 2000 FPM

Click on a category to view a selection of compatible accessories with the Dwyer 641B-4 Air Velocity Transmitter, 250 to 2000 FPM.

Ask a question about Dwyer 641B-4 Air Velocity Transmitter, 250 to 2000 FPM

Customer Reviews for the Dwyer 641B-4

More Dwyer Products