Model: PS48HD-C-D-N

Ideal for superior energy measurements, this versatile multi-circuit power submeter features 48 channels for monitoring voltage, current, power, energy, and many other electrical parameters on any combination of single and three-phase systems. In addition, this revenue-grade submeter comes with an enclosure and a display.

Ideal for superior energy measurements, this versatile multi-circuit power submeter features 48 channels for monitoring voltage, current, power, energy, and many other electrical parameters on any combination of single and three-phase systems. In addition, this revenue-grade submeter comes with an enclosure and a display.

Sale Price $3301.83 CAD
Regular Price $3494.00 CAD
Availability 1 in Stock
Quantity

Dent PS48HD-C-D-N Offers

Features

  • 48 current channels - monitors voltage, current, power, energy, and many other electrical parameters on any combination of single and/or three-phase systems
  • Two independent voltage inputs allow the meter to be used on two systems simultaneously
  • Line-Powered - 90 to 600 V phase-to-phase power supply
  • Revenue grade - ANSI C12.20-2010 Class 0.2
  • Extra level of protection - high-voltage cover offers additional safety
  • Communications - utilize either BACnet or Modbus protocol over either serial or ethernet
  • Positive and negative Modbus registers/BACnet objects allow for the meter to be used on net metering projects
  • Mix-and-match a full range of split core or RoCoil Rogowski-style CTs, including several revenue-grade options
  • Display shows real-time information about the meter configuration and metered data
  • PhaseChek confirms proper CT orientation
  • CE Mark

Applications

  • Tenant submetering
  • Bi-directional metering
  • Data centers
  • Real-Time power monitoring in commercial, retail, and industrial environments

Dent PS48HD-C-D-N Specifications

Service Type Single phase, split phase, three phase-four wire (WYE), three phase-three wire (delta)
Power From L1 phase to L2 phase. 90 to 600 VAC RMS CAT III 50/60 Hz, 500 mA AC maximum
Power Out Unregulated 12 VDC output, 200 mA, self-resetting fuse
AC Protection 0.5 A fuse 200 kA interrupt capacity
Voltage Channels 80 to 346 V AC line-to-neutral, 600 V line-to-line, CAT III
Current Channels 48 channels, 0.525 VAC maximum, 333 mV CTs, 0 to 4000+ A, depending on CT
Maximum Current Input 150% of current transducer rating (mV CTs) to maintain accuracy. Measure up to 4000 A with RōCoil CTs
Measurement Type True RMS using high-speed digital signal processing (DSP) with continuous sampling
Line Frequency 50/60 Hz
Waveform Sampling 1.8 kHz
Parameter Update Rate 1 second
Measurements Volts, amps, kW, kVAR, kVA, aPF, dPF, kW demand, kVA demand, import (received) kWh, export (delivered) kWh, net kWh, import (received) kVAh, export (delivered) kVAh, net kVAh, import (received) kVARh, export (delivered) kVARh, net kVARh, THD, theta, frequency. All parameters for each phase and system total
Accuracy 0.2% ANSI C12.20-2010 Class 0.2
Resolution Values reported in IEEE-754 single precision floating point format (32 bit)
Display 4-line display, tri-color backlight (PhaseChek)
Hardware RS-485, Ethernet, and USB (for ViewPoint HD use only)
Supported Protocols Modbus (using SunSpec IEEE-754 single precision floating point model), or BACnet
Max Distance 1200 meters with data range of 100 K bits per second or less
Supported BAUD Rates 9600, 19200, 38400, 57600, 76800, 115200
Data Bits 8
Parity None, even, odd
Stop Bit 2, 1
Data Formats Modbus, BACnet MS/TP, Modbus TCP or BACnet IP
Dimensions 13.5 x 10 x 3" (34.3 x 25.4 x 7.6 cm)
Click here for complete specifications on the Dent PS48HD-C-D-N

What's included with the Dent PS48HD-C-D-N

  • Dent PS48HD-C-D-N PowerScout 48 HD Multi-Circuit Power Submeter with enclosure and display

Ask a question about Dent PS48HD-C-D-N PowerScout 48 HD Multi-Circuit Power Submeter with enclosure and display

Customer Reviews for the Dent PS48HD-C-D-N

Dent PS48HD-C-D-N Offers

Features

  • 48 current channels - monitors voltage, current, power, energy, and many other electrical parameters on any combination of single and/or three-phase systems
  • Two independent voltage inputs allow the meter to be used on two systems simultaneously
  • Line-Powered - 90 to 600 V phase-to-phase power supply
  • Revenue grade - ANSI C12.20-2010 Class 0.2
  • Extra level of protection - high-voltage cover offers additional safety
  • Communications - utilize either BACnet or Modbus protocol over either serial or ethernet
  • Positive and negative Modbus registers/BACnet objects allow for the meter to be used on net metering projects
  • Mix-and-match a full range of split core or RoCoil Rogowski-style CTs, including several revenue-grade options
  • Display shows real-time information about the meter configuration and metered data
  • PhaseChek confirms proper CT orientation
  • CE Mark

Applications

  • Tenant submetering
  • Bi-directional metering
  • Data centers
  • Real-Time power monitoring in commercial, retail, and industrial environments

Dent PS48HD-C-D-N Specifications

Service Type Single phase, split phase, three phase-four wire (WYE), three phase-three wire (delta)
Power From L1 phase to L2 phase. 90 to 600 VAC RMS CAT III 50/60 Hz, 500 mA AC maximum
Power Out Unregulated 12 VDC output, 200 mA, self-resetting fuse
AC Protection 0.5 A fuse 200 kA interrupt capacity
Voltage Channels 80 to 346 V AC line-to-neutral, 600 V line-to-line, CAT III
Current Channels 48 channels, 0.525 VAC maximum, 333 mV CTs, 0 to 4000+ A, depending on CT
Maximum Current Input 150% of current transducer rating (mV CTs) to maintain accuracy. Measure up to 4000 A with RōCoil CTs
Measurement Type True RMS using high-speed digital signal processing (DSP) with continuous sampling
Line Frequency 50/60 Hz
Waveform Sampling 1.8 kHz
Parameter Update Rate 1 second
Measurements Volts, amps, kW, kVAR, kVA, aPF, dPF, kW demand, kVA demand, import (received) kWh, export (delivered) kWh, net kWh, import (received) kVAh, export (delivered) kVAh, net kVAh, import (received) kVARh, export (delivered) kVARh, net kVARh, THD, theta, frequency. All parameters for each phase and system total
Accuracy 0.2% ANSI C12.20-2010 Class 0.2
Resolution Values reported in IEEE-754 single precision floating point format (32 bit)
Display 4-line display, tri-color backlight (PhaseChek)
Hardware RS-485, Ethernet, and USB (for ViewPoint HD use only)
Supported Protocols Modbus (using SunSpec IEEE-754 single precision floating point model), or BACnet
Max Distance 1200 meters with data range of 100 K bits per second or less
Supported BAUD Rates 9600, 19200, 38400, 57600, 76800, 115200
Data Bits 8
Parity None, even, odd
Stop Bit 2, 1
Data Formats Modbus, BACnet MS/TP, Modbus TCP or BACnet IP
Dimensions 13.5 x 10 x 3" (34.3 x 25.4 x 7.6 cm)
Click here for complete specifications on the Dent PS48HD-C-D-N

What's included with the Dent PS48HD-C-D-N

  • Dent PS48HD-C-D-N PowerScout 48 HD Multi-Circuit Power Submeter with enclosure and display

Ask a question about Dent PS48HD-C-D-N PowerScout 48 HD Multi-Circuit Power Submeter with enclosure and display

Customer Reviews for the Dent PS48HD-C-D-N

More Dent Products