The power meter with a wall mount enclosure is a revenue grade instrument for superior energy measurement. It features three channels that monitor voltage, current, power, energy, and many other electrical parameters on single or three-phase systems.
The power meter with a wall mount enclosure is a revenue grade instrument for superior energy measurement. It features three channels that monitor voltage, current, power, energy, and many other electrical parameters on single or three-phase systems.
Features
Revenue-grade performance
With high speed continuous sampling, data updates rate of 1 Hz and ANSI C12.20-2015 Class 0.2 revenue grade accuracy (depending on CT), the PowerScout 3 HD is well-suited for accountability metering in commercial, retail, and industrial facilities including demand response and tenant submetering.
Line or USB powered
The power meter is line-powered with an internal wide-range power supply, allowing line-to-line voltages from 90 to 600 VAC. For convenience, it also includes a USB (Type C) connector which allows the meter to be powered from a host PC or laptop computer during configuration.
Industry-standard Modbus or BACnet
The power meter supports both Modbus (based on SunSpec IEEE-754) and BACnet communications protocols. Communications interface can be accomplished through serial RS-485 or Ethernet using either Modbus RTU, BACnet MS/TP, Modbus TCP, or BACnet IP protocols.
Quick setup
It can be configured using one of two interfaces: PC Application ViewPoint HD or Web Browser. Configurations can be saved to a template for re-use. Use the on-board LCD and thumb wheel to verify setup.
Power troubleshooting
Includes PhaseChek™ circuitry for identifying mis-phased and backwards CTs. When used in conjunction with ViewPoint HD, advanced analytics are available including waveform visualization, vector polar plotting and harmonic distortion analysis.
Applications
Service Type | Single-phase, three phase-four wire (WYE), three phase-three wire (Delta) |
Power | From L1 Phase to L2 Phase. 90 to 600 VAC RMS CAT III 50/60 Hz, 500 mA AC maximum |
AC Protection | 0.5 A internal fuse protection. 200 KA interrupt |
Channels | Voltage: 80 to 346 V AC line-to-neutral, 600 V line-to-line, CAT III Current: 3 channels, 0.525 VAC maximum, 333 mV CTs, 0 to 4000+ A depending on CT |
Maximum Current Input | 150% of current transducer rating (mV CTs) to maintain accuracy Measure up to 4000 A with RoCoil CTs |
Measurement Type | True RMS using high-speed digital signal processing (DSP) |
Line Frequency | 50/60 Hz |
Sampling | Continuous 1.8 kHz (no blind cycles) |
Parameter Update Rate | 1.0 second |
Measurements | Volts, Amps, kW, kVAR, kVA, aPF, dPF, kW demand, kVA demand, Import (received) kWh, Export (delivered) kWh, Net kWh, Import (received) kVAh, Export (delivered) kVAh, Net kVAh, Import (received) kVARh, Export (delivered) kVARh, Net kVARh, THD, Theta, Frequency. All parameters for each phase and element total |
Resolution | 32-bit floating point |
Display | 2 x 16 character display with tri-color backlight |
Hardware | RS-485 Serial and Ethernet |
Maximum Communication Length | 1200 meters at 100K bits/second or less |
Communication Rate (Baud) | Modbus: 9600, 19200, 38400, 57600, 76800, 115200 baud BACnet: 9600, 19200, 38400, 76800 |
Data Bits | 8 |
Parity | None, Even, Odd |
Stop Bit | 2, 1 |
Supported Protocols | Modbus RTU, BACnet MS/TP, Modbus TCP or BACnet IP |
Wire Connections | 12 to 28 AWG 600 VAC, voltage connection must be #14 AWG or larger and 600 VAC rated |
Mounting | Wall mount enclosure |
Operating Temperature | -4 to 140°F (-20 to 60°C) |
Humidity | 5 to 95% non-condensing |
Enclosure | ABS Plastic, 94-V0 flammability rating |
Dimensions | 10.12 x 5.5 x 2.12" (25.7 x 14 x 5.37 cm) |
Weight | Approximately 22 oz (635 g) |
Certifications | UL listed: Conforms to UL Std 61010-1, 3rd Edition & IEC 61010-2-030 1st Edition CE: LVD (EN61010-1), EMC (EN61326-1), RoHS 2 (EN50581) |
Service Type | Single-phase, three phase-four wire (WYE), three phase-three wire (Delta) |
Power | From L1 Phase to L2 Phase. 90 to 600 VAC RMS CAT III 50/60 Hz, 500 mA AC maximum |
AC Protection | 0.5 A internal fuse protection. 200 KA interrupt |
Channels | Voltage: 80 to 346 V AC line-to-neutral, 600 V line-to-line, CAT III Current: 3 channels, 0.525 VAC maximum, 333 mV CTs, 0 to 4000+ A depending on CT |
Maximum Current Input | 150% of current transducer rating (mV CTs) to maintain accuracy Measure up to 4000 A with RoCoil CTs |
Measurement Type | True RMS using high-speed digital signal processing (DSP) |
Line Frequency | 50/60 Hz |
Sampling | Continuous 1.8 kHz (no blind cycles) |
Parameter Update Rate | 1.0 second |
Measurements | Volts, Amps, kW, kVAR, kVA, aPF, dPF, kW demand, kVA demand, Import (received) kWh, Export (delivered) kWh, Net kWh, Import (received) kVAh, Export (delivered) kVAh, Net kVAh, Import (received) kVARh, Export (delivered) kVARh, Net kVARh, THD, Theta, Frequency. All parameters for each phase and element total |
Resolution | 32-bit floating point |
Display | 2 x 16 character display with tri-color backlight |
Hardware | RS-485 Serial and Ethernet |
Maximum Communication Length | 1200 meters at 100K bits/second or less |
Communication Rate (Baud) | Modbus: 9600, 19200, 38400, 57600, 76800, 115200 baud BACnet: 9600, 19200, 38400, 76800 |
Data Bits | 8 |
Parity | None, Even, Odd |
Stop Bit | 2, 1 |
Supported Protocols | Modbus RTU, BACnet MS/TP, Modbus TCP or BACnet IP |
Wire Connections | 12 to 28 AWG 600 VAC, voltage connection must be #14 AWG or larger and 600 VAC rated |
Mounting | Wall mount enclosure |
Operating Temperature | -4 to 140°F (-20 to 60°C) |
Humidity | 5 to 95% non-condensing |
Enclosure | ABS Plastic, 94-V0 flammability rating |
Dimensions | 10.12 x 5.5 x 2.12" (25.7 x 14 x 5.37 cm) |
Weight | Approximately 22 oz (635 g) |
Certifications | UL listed: Conforms to UL Std 61010-1, 3rd Edition & IEC 61010-2-030 1st Edition CE: LVD (EN61010-1), EMC (EN61326-1), RoHS 2 (EN50581) |