A complete and convenient portable power metering solution for load studies and energy audits, this kit includes the line-powered ELITEpro XC of your choice, plus quick-to-install flexible RoCoil CTs that measure from 0.5 right up to 6500A.
A complete and convenient portable power metering solution for load studies and energy audits, this kit includes the line-powered ELITEpro XC of your choice, plus quick-to-install flexible RoCoil CTs that measure from 0.5 right up to 6500A.
These meters can capture kWh/kW energy and demand data as well as virtually all relevant energy parameters for diagnostics and monitoring on three-phase or single-phase circuit installations. Electrical load diagnostic parameters, such as displacement power factor, are captured in addition to energy and demand values.
The ELITEpro XC's flexibility, size, and ease-of-use make it the ideal tool for gathering detailed consumption information in commercial, industrial, government and retail environments.
Four Analog Input Channels: Correlate your consumption with environmental conditions.
New to the ELITEpro XC are 4 analog input channels which can be configured for voltage or current input used in any combination among channels. Analog inputs are especially helpful when used in conjunction with power measurements to correlate the consumption of electricity with environmental, HVAC/R plant performance, or other process conditions. Typical uses might include logging ambient temperature, building temperatures, solar insolation, tank pressures, duct flows, etc. Obtain this valuable data using just one meter: the ELITEpro XC.
An Industry-Leading Selection of Quality Transformers
Choose from an interchangeable selection of CT options including split-core, clamp-on, hinged and flexible RoCoil™ types. The ELITEpro XC comes with an embedded Rogowski coil CT amplifier/integrator circuit so there is no need to provide external power when using our line of flexible RoCoil™ CTs.
All DENT CTs are internally shunted for intrinsically safe operation on energized conductors. Special high-accuracy CTs are available for existing CT secondary monitoring. The ELITEpro XC can monitor up to four single-phase loads, two three-phase (3-wire) Delta loads or one three-phase (4-wire) WYE load.
Case Study - ELITEpro XC: A Key Tool for Auditing Compressed Air Systems
Software
Setup, download & analyze
ELOG software is used to program the meter, display metered values, and retrieve and analyze the collected data.
ELOG graphically displays recorded data, performs analysis, and facilitates automatic remote data collection. Data is also easily exported to popular spreadsheet and database programs for additional analysis.
You are provided with an unlimited site license to the software with purchase.
Specifications
Technical | |
---|---|
Service Type | Single Phase (two wire or three wire), Three Phase-Four Wire (WYE), Three Phase-Three Wire (Delta), DC Systems (Solar/Battery) |
Voltage Channels | 3 channels, CAT III, 0-600 VAC (line-to-line) or 600 VDC |
Current Channels | 4 channels, .67 VAC max, ± 1 VDC. Ideal for 333 mV full scale CTs |
Maximum Current Input | External transducer dependent. 200% of current transducer rating (mV CTs) Measure up to 6000A with RoCoil CTs. |
Measurement Type | True RMS using high-speed digital signal processing (DSP) |
Line Frequency | DC/50/60/400 Hz* |
Waveform Sampling | 12 kHz |
Channel Sampling Rate | .125 seconds |
Integration Period | 1, 3, 15, 30 seconds; 1, 2, 5, 10, 15, 20, and 30 minutes; 1 and 12 hours, 1 day |
Energy Measurements | Volts, Amps, Amp-Hrs (Ah), kW, kWh, kVAR, kVARh, kVA, kVAh, Displacement Power Factor (dPF). All parameters for each phase and for system total. |
Analog Measurements | 0-10 Volts, 0 or 4-20 mA current loop. Non-isolated, external power for current loop. User scaling for sensor reporting in physical units. |
Accuracy | Better than 1% (<0.2% typical) for V, A, kW, kVAR, kVA, PF, Analog |
Resolution | 0.01 Amp, 0.1 Volt, 1 Watt, 1 VAR, 1 VA, 0.01 PF, 0.01 ANA |
LED Indicators | Tri-color (red, green, blue): 1 LED indicates communication (blue for wireless, Bluetooth® or Ethernet), 4 LEDs for correct phasing (PhaseChek™). |
Power | |
Line-Power | From L1 Phase to L2 Phase. 80-600V (AC or DC) CAT III DC/50/60/400 Hz, 125 mA, 5 W, or 10 VA max. Non-user replaceable .5 Amp internal fuse protection. |
Power In | 6-10 VDC, 500 mA |
Power Out | 6 VDC, 200 mA max |
Communications | |
USB (Standard) | USB standard (Type B). 1.8 M (6 ft) A-to-B USB Cable (included) |
Ethernet (Standard) | Standard RJ-45 Connector supports 10/100 MB Ethernet over Cat 5 or better. Configure for DHCP or Static IP. |
Bluetooth Wireless Technology (Optional) | Internal antenna with 10-100 ft range (typical). Requires Bluetooth® wireless technology adapter on Windows PC. Adapter must support the Serial Port Profile (SPP). |
Wi-Fi Adapter† (optional) | Wi-Fi option available as two separate configurations:
|
Mechanical | |
Operating Temperature | -7 to + 60 °C (20 to 140 °F) |
Operating Humidity | 5% to 95% non-condensing |
Enclosure Type | ABS plastic, 94-V0 flammability rating |
Weight | 340 g (12 ounces) |
Dimensions | 21.6 x 6.3 x 4.7 cm (8.5" x 2.5" x 1.9") |
* Performance varies at 400 Hz operation. Contact the factory for details.
† ELITEpro XC loggers that are equipped with a Wi-Fi package contain an internal antenna. An external antenna
is optional. You may toggle between using the internal and external antenna (if it is available on your logger) by
checking or unchecking the Use External Antenna checkbox in ELOG.
US/NORTH AMERICAN ELITEpro XC configuration includes 4 color (black, blue, red, white) voltage leads and
croc clips. INTERNATIONAL ELITEpro XC configuration includes 3 black voltage lead connections, 1 white
connection (neutral) and 5 color (black, blue, red, white, yellow) voltage leads and croc clips.
Software
Setup, download & analyze
ELOG software is used to program the meter, display metered values, and retrieve and analyze the collected data.
ELOG graphically displays recorded data, performs analysis, and facilitates automatic remote data collection. Data is also easily exported to popular spreadsheet and database programs for additional analysis.
You are provided with an unlimited site license to the software with purchase.
Specifications
Technical | |
---|---|
Service Type | Single Phase (two wire or three wire), Three Phase-Four Wire (WYE), Three Phase-Three Wire (Delta), DC Systems (Solar/Battery) |
Voltage Channels | 3 channels, CAT III, 0-600 VAC (line-to-line) or 600 VDC |
Current Channels | 4 channels, .67 VAC max, ± 1 VDC. Ideal for 333 mV full scale CTs |
Maximum Current Input | External transducer dependent. 200% of current transducer rating (mV CTs) Measure up to 6000A with RoCoil CTs. |
Measurement Type | True RMS using high-speed digital signal processing (DSP) |
Line Frequency | DC/50/60/400 Hz* |
Waveform Sampling | 12 kHz |
Channel Sampling Rate | .125 seconds |
Integration Period | 1, 3, 15, 30 seconds; 1, 2, 5, 10, 15, 20, and 30 minutes; 1 and 12 hours, 1 day |
Energy Measurements | Volts, Amps, Amp-Hrs (Ah), kW, kWh, kVAR, kVARh, kVA, kVAh, Displacement Power Factor (dPF). All parameters for each phase and for system total. |
Analog Measurements | 0-10 Volts, 0 or 4-20 mA current loop. Non-isolated, external power for current loop. User scaling for sensor reporting in physical units. |
Accuracy | Better than 1% (<0.2% typical) for V, A, kW, kVAR, kVA, PF, Analog |
Resolution | 0.01 Amp, 0.1 Volt, 1 Watt, 1 VAR, 1 VA, 0.01 PF, 0.01 ANA |
LED Indicators | Tri-color (red, green, blue): 1 LED indicates communication (blue for wireless, Bluetooth® or Ethernet), 4 LEDs for correct phasing (PhaseChek™). |
Power | |
Line-Power | From L1 Phase to L2 Phase. 80-600V (AC or DC) CAT III DC/50/60/400 Hz, 125 mA, 5 W, or 10 VA max. Non-user replaceable .5 Amp internal fuse protection. |
Power In | 6-10 VDC, 500 mA |
Power Out | 6 VDC, 200 mA max |
Communications | |
USB (Standard) | USB standard (Type B). 1.8 M (6 ft) A-to-B USB Cable (included) |
Ethernet (Standard) | Standard RJ-45 Connector supports 10/100 MB Ethernet over Cat 5 or better. Configure for DHCP or Static IP. |
Bluetooth Wireless Technology (Optional) | Internal antenna with 10-100 ft range (typical). Requires Bluetooth® wireless technology adapter on Windows PC. Adapter must support the Serial Port Profile (SPP). |
Wi-Fi Adapter† (optional) | Wi-Fi option available as two separate configurations:
|
Mechanical | |
Operating Temperature | -7 to + 60 °C (20 to 140 °F) |
Operating Humidity | 5% to 95% non-condensing |
Enclosure Type | ABS plastic, 94-V0 flammability rating |
Weight | 340 g (12 ounces) |
Dimensions | 21.6 x 6.3 x 4.7 cm (8.5" x 2.5" x 1.9") |
* Performance varies at 400 Hz operation. Contact the factory for details.
† ELITEpro XC loggers that are equipped with a Wi-Fi package contain an internal antenna. An external antenna
is optional. You may toggle between using the internal and external antenna (if it is available on your logger) by
checking or unchecking the Use External Antenna checkbox in ELOG.
US/NORTH AMERICAN ELITEpro XC configuration includes 4 color (black, blue, red, white) voltage leads and
croc clips. INTERNATIONAL ELITEpro XC configuration includes 3 black voltage lead connections, 1 white
connection (neutral) and 5 color (black, blue, red, white, yellow) voltage leads and croc clips.