International recording power meter with USB/Ethernet communications plus Wi-Fi adapter with internal antenna (75-300 '), includes crocodile clips. Capture kWh/kW energy and demand data as well as virtually all relevant energy parameters for diagnostics and monitoring on three-phase or single-phase circuit installations. Please note that all DENT software is compatible with Windows 7 and newer operating systems. It is not compatible with macOS. Includes soft carrying case.
International recording power meter with USB/Ethernet communications plus Wi-Fi adapter with internal antenna (75-300 '), includes crocodile clips. Capture kWh/kW energy and demand data as well as virtually all relevant energy parameters for diagnostics and monitoring on three-phase or single-phase circuit installations. Please note that all DENT software is compatible with Windows 7 and newer operating systems. It is not compatible with macOS. Includes soft carrying case.
The Dent ELITEpro XC Energy Datalogger is ideal for the measurement and analysis of energy consumption data, gathered from analog voltage and current inputs. This model features an internal Wi-Fi antenna, includes a set of crocodile clips and a case, and is designed for international use. The ELITEpro XC features configurable analog inputs with a voltage transducer range of 0 to 10VDC and a current loop transducer range of 0 or 4 to 20mA. This datalogger may be used on single or three-phase systems, using phase-to-phase services of a range of 80 to 600V (AC or DC) when line powered and 0 to 600V (AC or DC) when externally powered.
The ELITEpro XC is easy to use, with a simple setup and DENT's patended PhaseChek indicator to ensure proper instillation. This datalogger communicated quickly via USB connection and features a standard Ethernet port. Its compact, durable design means the ELITEpro XC can fit easily inside of breaker panels-making it the ideal datalogger for energy audits, surveys, and load profiling.
Technical Specifications:
Communication Specifications:
Technical | |
---|---|
Service Type | Single phase (two wire or three wire), three phase-four wire (WYE), three phase-three wire (Delta), DC systems (solar/battery) |
Voltage Channels | 3 channels, CAT III, 0 to 600 VAC (line-to-line) or 600 VDC |
Current Channels | 4 channels, 0.67 VAC max, +/- 1 VDC Ideal for 333 mV full scale CTs |
Maximum Current Input | External transducer dependent 200% of current transducer rating (mV CTs) Measure up to 6000 A with RoCoil CTs. |
Measurement Type | True RMS using high-speed digital signal processing (DSP) |
Line Frequency | DC/50/60/400 Hz* |
Waveform Sampling | 12 kHz |
Channel Sampling Rate | 0.125 seconds |
Integration Period | 1, 3, 15, 30 seconds; 1, 2, 5, 10, 15, 20, and 30 minutes; 1 and 12 hours, 1 day |
Energy Measurements | Volts, Amps, Amp-Hrs (Ah), kW, kWh, kVAR, kVARh, kVA, kVAh, Displacement Power Factor (dPF). All parameters for each phase and for system total |
Analog Measurements | 0 to 10 V, 0 or 4 to 20 mA current loop Non-isolated, external power for current loop. User scaling for sensor reporting in physical units |
Accuracy | Better than 1% (<0.2% typical) for V, A, kW, kVAR, kVA, PF, Analog |
Resolution | 0.01 A, 0.1 V, 1 W, 1 VAR, 1 VA, 0.01 PF, 0.01 ANA |
LED Indicators | Tri-color (red, green, blue): 1 LED indicates communication (blue for wireless, Bluetooth® or Ethernet), 4 LEDs for correct phasing (PhaseChek™). |
Power | |
Line-Power | From L1 Phase to L2 Phase. 80 to 600 V (AC or DC) CAT III DC/50/60/400 Hz, 125 mA, 5 W, or 10 VA max Non-user replaceable 0.5 A internal fuse protection. |
Power In | 6 to 10 VDC, 500 mA |
Power Out | 6 VDC, 200 mA max |
Communications | |
USB (Standard) | USB standard (type B) 6' (1.8 m) A-to-B USB cable (included) |
Ethernet (Standard) | Standard RJ-45 connector supports 10/100 MB Ethernet over Cat 5 or better Configure for DHCP or static IP |
Bluetooth Wireless Technology (Optional) | Internal antenna with 10 to 100' range (typical) Requires Bluetooth® wireless technology adapter on Windows PC Adapter must support the Serial Port Profile (SPP). |
Wi-Fi Adapter† (optional) | Wi-Fi option available as two separate configurations:
|
Mechanical | |
Operating Temperature | 20 to 140 °F (-7 to 60 °C) |
Operating Humidity | 5 to 95% non-condensing |
Enclosure Type | ABS plastic, 94-V0 flammability rating |
Weight | 12 ounces (340 g) |
Dimensions | 8.5 x 2.5 x 1.9" (21.6 x 6.3 x 4.7 cm) |
* Performance varies at 400 Hz operation. Contact the factory for details.
† ELITEpro XC loggers that are equipped with a Wi-Fi package contain an internal antenna. An external antenna
is optional. You may toggle between using the internal and external antenna (if it is available on your logger) by
checking or unchecking the Use External Antenna checkbox in ELOG.
US/NORTH AMERICAN ELITEpro XC configuration includes 4 color (black, blue, red, white) voltage leads and
croc clips. INTERNATIONAL ELITEpro XC configuration includes 3 black voltage lead connections, 1 white
connection (neutral) and 5 color (black, blue, red, white, yellow) voltage leads and croc clips.
What happens if your ELITEpro XC is on a local area network at a remote project site, but you're hundreds of miles away, at your office, and need to download data off the meter? Port Forwarding makes it possible to complete the download and, with a little planning, you probably already have everything you need to successfully download your data.
Port forwarding is a name given to the combined technique of:
Port forwarding allows remote computers (for example, computers on the Internet) to connect to a specific computer or service within a private local area network (LAN). In the case of the ELITEpro XC (or ELITEpro SP) with Ethernet, port forwarding allows remote connection between the ELITEpro XC and a computer on another network through the firewall via ELOG software.
For instance, if the ELITEpro XC is on the local area network at a remote project site, but you wish to download data off the meter from the office, you can remotely access the ELITEpro XC from any computer with an Internet connection through ELOG.
Requirements
Prior to beginning, confirm the following information:
Note: The ELITEpro XC itself does not need to be configured for Port Forwarding. All the configuration takes place on the router.
Each router manufacturer uses slightly different software. Check your router's documentation for specific directions on how to port forward with your router's software. Regardless of what software is on your router, you'll be required to enter the same general information.
Instructions
Here are the steps to connecting your networked ELITEpro XC from a different network:
Click on a category to view a selection of compatible accessories with the Dent ElitePro EXC-I-WI-C Energy Data Logger, Int'l, Int. Wi-Fi.
Technical | |
---|---|
Service Type | Single phase (two wire or three wire), three phase-four wire (WYE), three phase-three wire (Delta), DC systems (solar/battery) |
Voltage Channels | 3 channels, CAT III, 0 to 600 VAC (line-to-line) or 600 VDC |
Current Channels | 4 channels, 0.67 VAC max, +/- 1 VDC Ideal for 333 mV full scale CTs |
Maximum Current Input | External transducer dependent 200% of current transducer rating (mV CTs) Measure up to 6000 A with RoCoil CTs. |
Measurement Type | True RMS using high-speed digital signal processing (DSP) |
Line Frequency | DC/50/60/400 Hz* |
Waveform Sampling | 12 kHz |
Channel Sampling Rate | 0.125 seconds |
Integration Period | 1, 3, 15, 30 seconds; 1, 2, 5, 10, 15, 20, and 30 minutes; 1 and 12 hours, 1 day |
Energy Measurements | Volts, Amps, Amp-Hrs (Ah), kW, kWh, kVAR, kVARh, kVA, kVAh, Displacement Power Factor (dPF). All parameters for each phase and for system total |
Analog Measurements | 0 to 10 V, 0 or 4 to 20 mA current loop Non-isolated, external power for current loop. User scaling for sensor reporting in physical units |
Accuracy | Better than 1% (<0.2% typical) for V, A, kW, kVAR, kVA, PF, Analog |
Resolution | 0.01 A, 0.1 V, 1 W, 1 VAR, 1 VA, 0.01 PF, 0.01 ANA |
LED Indicators | Tri-color (red, green, blue): 1 LED indicates communication (blue for wireless, Bluetooth® or Ethernet), 4 LEDs for correct phasing (PhaseChek™). |
Power | |
Line-Power | From L1 Phase to L2 Phase. 80 to 600 V (AC or DC) CAT III DC/50/60/400 Hz, 125 mA, 5 W, or 10 VA max Non-user replaceable 0.5 A internal fuse protection. |
Power In | 6 to 10 VDC, 500 mA |
Power Out | 6 VDC, 200 mA max |
Communications | |
USB (Standard) | USB standard (type B) 6' (1.8 m) A-to-B USB cable (included) |
Ethernet (Standard) | Standard RJ-45 connector supports 10/100 MB Ethernet over Cat 5 or better Configure for DHCP or static IP |
Bluetooth Wireless Technology (Optional) | Internal antenna with 10 to 100' range (typical) Requires Bluetooth® wireless technology adapter on Windows PC Adapter must support the Serial Port Profile (SPP). |
Wi-Fi Adapter† (optional) | Wi-Fi option available as two separate configurations:
|
Mechanical | |
Operating Temperature | 20 to 140 °F (-7 to 60 °C) |
Operating Humidity | 5 to 95% non-condensing |
Enclosure Type | ABS plastic, 94-V0 flammability rating |
Weight | 12 ounces (340 g) |
Dimensions | 8.5 x 2.5 x 1.9" (21.6 x 6.3 x 4.7 cm) |
* Performance varies at 400 Hz operation. Contact the factory for details.
† ELITEpro XC loggers that are equipped with a Wi-Fi package contain an internal antenna. An external antenna
is optional. You may toggle between using the internal and external antenna (if it is available on your logger) by
checking or unchecking the Use External Antenna checkbox in ELOG.
US/NORTH AMERICAN ELITEpro XC configuration includes 4 color (black, blue, red, white) voltage leads and
croc clips. INTERNATIONAL ELITEpro XC configuration includes 3 black voltage lead connections, 1 white
connection (neutral) and 5 color (black, blue, red, white, yellow) voltage leads and croc clips.
What happens if your ELITEpro XC is on a local area network at a remote project site, but you're hundreds of miles away, at your office, and need to download data off the meter? Port Forwarding makes it possible to complete the download and, with a little planning, you probably already have everything you need to successfully download your data.
Port forwarding is a name given to the combined technique of:
Port forwarding allows remote computers (for example, computers on the Internet) to connect to a specific computer or service within a private local area network (LAN). In the case of the ELITEpro XC (or ELITEpro SP) with Ethernet, port forwarding allows remote connection between the ELITEpro XC and a computer on another network through the firewall via ELOG software.
For instance, if the ELITEpro XC is on the local area network at a remote project site, but you wish to download data off the meter from the office, you can remotely access the ELITEpro XC from any computer with an Internet connection through ELOG.
Requirements
Prior to beginning, confirm the following information:
Note: The ELITEpro XC itself does not need to be configured for Port Forwarding. All the configuration takes place on the router.
Each router manufacturer uses slightly different software. Check your router's documentation for specific directions on how to port forward with your router's software. Regardless of what software is on your router, you'll be required to enter the same general information.
Instructions
Here are the steps to connecting your networked ELITEpro XC from a different network:
Click on a category to view a selection of compatible accessories with the Dent ElitePro EXC-I-WI-C Energy Data Logger, Int'l, Int. Wi-Fi.