The AC/DC current probe is a hall effect current probe with 2 ranges designed for DMM, data loggers, and power analyzers. It has a 5' (1.5 m) lead terminated by 0.16" (4 mm) safety banana plugs and can measure up to 1000 AAC and 1400 ADC. It is powered by a 9 V battery or by a standard 5 V external power supply via a micro-USB connector.
The AC/DC current probe is a hall effect current probe with 2 ranges designed for DMM, data loggers, and power analyzers. It has a 5' (1.5 m) lead terminated by 0.16" (4 mm) safety banana plugs and can measure up to 1000 AAC and 1400 ADC. It is powered by a 9 V battery or by a standard 5 V external power supply via a micro-USB connector.
The AC/DC current probe measure AC and DC currents without opening the circuit in which the currents flow.
Features
Applications
Current Range | 0.5 to 100 AAC, 150 ADC & 0.5 to 1000 AAC, 1400 ADC |
Output Signal | 10 mV/A & 1 mV/A via a 5' (1.5 m) lead with 0.16" (4 mm) safety banana plug |
Accuracy 50/60 Hz | ≤1.5% @ 100 A & ≤2.5% @ 800 A |
Frequency Range | DC to 30 kHz (-3 dB) (depending of current value) |
Phase Shift At 50 Hz | ≤2°@ 100 A ≤1.5° @ 800 A |
Load Impedance | >1 MΩ and ≤100 pF |
Battery Life | 50 H typical |
Operating Temperature | 14 to 131°F (-10 to 55°C) |
Relative Humidity | Up to 85% @ 35°C |
Dimensions (H x W x D) | 9.31 x 3.82 x 1.73" (236.5 x 97 x 44 mm) |
Current Range | 0.5 to 100 AAC, 150 ADC & 0.5 to 1000 AAC, 1400 ADC |
Output Signal | 10 mV/A & 1 mV/A via a 5' (1.5 m) lead with 0.16" (4 mm) safety banana plug |
Accuracy 50/60 Hz | ≤1.5% @ 100 A & ≤2.5% @ 800 A |
Frequency Range | DC to 30 kHz (-3 dB) (depending of current value) |
Phase Shift At 50 Hz | ≤2°@ 100 A ≤1.5° @ 800 A |
Load Impedance | >1 MΩ and ≤100 pF |
Battery Life | 50 H typical |
Operating Temperature | 14 to 131°F (-10 to 55°C) |
Relative Humidity | Up to 85% @ 35°C |
Dimensions (H x W x D) | 9.31 x 3.82 x 1.73" (236.5 x 97 x 44 mm) |