ACR 01-0012 SmartReader Plus 5 Data Logger

Model: ACR 01-0012 | Order No: 01-0012

ACR 01-0012 SmartReader Plus 5 Data Logger

Model: ACR 01-0012 | Order No: 01-0012

Use this smartreader plus for applications that require monitoring extremely high temperatures or monitoring temperature over a wide range. Additionally, it comes with one internal channel for measuring ambient temperature and two external channels for use with ACR thermocouple wire or any J, K, S, T or E type thermocouple wire.

Use this smartreader plus for applications that require monitoring extremely high temperatures or monitoring temperature over a wide range. Additionally, it comes with one internal channel for measuring ambient temperature and two external channels for use with ACR thermocouple wire or any J, K, S, T or E type thermocouple wire.

Your Price $768.00 CAD
Availability 2 to 3 Weeks
Quantity

ISO Certified In-House Calibration Certificate for your ACR 01-0012 SmartReader Plus 5 Data Logger

ISO Certified In-House Calibration Certificate for your ACR 01-0012 SmartReader Plus 5 Data Logger

ACR ACR 01-0012 Offers

Features

  • Three channels
  • Monitor extremely high temperatures
  • Monitor temperature over a wide range
  • Use with a variety of different thermocouple probes
  • Greater resolution and accuracy than SR5

Applications

  • Monitor performance of gas-fired heating equipment
  • Verifying concrete curing temperatures
  • Process verification

ACR ACR 01-0012 Specifications

Temperature Sensor (Internal)
Type NTC Thermistor - 10,000 Ω at 77˚F (25˚C)
Range -40 to 158˚F (-40 to 70°C)
Accuracy +/-0.3ºF over the range of 32 to 158ºF (+/-0.2ºC over the range of 0 to 70ºC)
Resolution 0.05ºF (0.03ºC) at 25ºC; better than 0.12ºF (0.07ºC) between -13 and 158ºF (-25 and 70˚C)
Better than 0.23˚F (0.13ºC) between -40 and -13ºF (-40 and -25˚C)
General Specifications
Software Requirements TrendReader® Standard 2 (compatible with Windows® 2000, and XP)
PC Requirements IBM PC or 100% compatible with at least one free serial port, 2 MB of RAM memory, and 2 MB of hard disk space
Operating Limits -40 to 158°F (-40 to 70°C) and 0 to 95% RH (non-condensing)
Sampling Methods Continuous (First-in, First-out), Stop When Full (Fill-then-stop)
Clock Accuracy +/-2 seconds per day
Mounting Magnetic backing or locking eyelet
Resolution 12-bit (1 part in 4096)
Battery 3.6 V Lithium
Case Material Noryl® plastic
Dimensions 4.2 x 2.9 x 0.9" (107 x x 74 x 22 mm)
Weight 3.75 oz (110 g)
Click here for complete specifications on the ACR ACR 01-0012

What's included with the ACR ACR 01-0012

  • ACR 01-0012 SmartReader Plus 5 Data Logger

Click on a category to view a selection of compatible accessories with the ACR 01-0012 SmartReader Plus 5 Data Logger.

ACR Fast Sampling Battery Pack BP-101 ACR 01-0078
Portable power supply for SmartReader Plus data loggers to allow them to sample faster than 8 seconds.




ACR 31-0016 Type-T Thermocouple Wire, bulk wire ACR 31-0016
The 20 gauge Type-J thermocouple wire features a duplex Teflon insulation jacket. It also features a measurement range of -325 to 750°F (-200 to 400°C). The wire comes sold by the foot.




ACR 31-0015 Type-K Thermocouple Wire, bulk wire ACR 31-0015
The 20 gauge Type-J thermocouple wire features a duplex Teflon insulation jacket. It also features a measurement range of -145 to 2100°F (-100 to 1150°C). The wire comes sold by the foot.




ACR 31-0014 Type-J Thermocouple Wire, bulk wire ACR 31-0014
The 20 gauge Type-J thermocouple wire features a duplex Teflon insulation jacket. It also features a measurement range of -55 to 1100°F (-50 to 600°C). The wire comes sold by the foot.




ACR 01-0104 Type-T Thermocouple Wire, welded tip ACR 01-0104
The 20 gauge Type-J thermocouple wire features a welded tip and a duplex insulated PVC jacket. It also features a measurement range of -325 to 750°F (-200 to 400°C) and is 12" in length.




ACR 01-0102 Type-J Thermocouple Wire , welded tip ACR 01-0102
The 20 gauge Type-J thermocouple wire features a welded tip and a duplex insulated Teflon jacket. It also features a measurement range of -55 to 1100°F (-50 to 600°C) and is 12" in length.




ACR 01-0088 Logger-PC Interface Cable, 4' ACR 01-0088
Connect the SmartReader Plus data logger to PC computer through a USB port with this interface cable which measures 4' (1.22 m). In addition, this interface cable has a 0.138" (3.5 mm) stereo jack connection.




ACR 01-0077 Logger-PC Interface Cable (IC-101) ACR 01-0077
9-pin PC serial port to logger interface cable. Compatible with SmartReader and SmartReader Plus loggers.




ACR 01-0103 Type-K Thermocouple Wire, welded tip ACR 01-0103
The 20 gauge Type-K thermocouple wire features a welded tip and a duplex insulated Teflon jacket. It also features a measurement range of -145 to 2100°F (-100 to 1150°C) and is 12" in length.




ACR 29-0004 Terminal Block - 11 Pin ACR 29-0004
11-pin female teminal block for SmartReader/SmartReader Plus sensor inputs.




ACR 01-0171 SmartReader Plus Display Module ACR 01-0171
Portable Real-time Display Module for any SmartReader Plus Data Logger (2 AA batteries and 1 foot cable included).




ACR 01-0168 Alarm Module - 100 - EU ACR 01-0168
Alarm module, stereo Y-adapter, 1ft male-male stereo cable, and 240V Cont. Europe power supply for SmartReader Plus loggers.




ACR 01-0167 Alarm Module - 100 - NA ACR 01-0167
Alarm module, stereo Y-adapter, 1ft male-male stereo cable, and 120V NA power supply for SmartReader Plus loggers.




ACR 01-0098 Network Y Splitter - Stereo (YA-200) ACR 01-0098
Allows a SmartReader Plus logger to be added to an ACR-stereo type network. 1 male and 2 female ends. Includes 1ft male to male adapter cable.




ACR Systems SC-100 General Purpose Logger Storage Case ACR 01-0106
General Purpose Logger Storage Case, Briefcase style, locking, customizable logger and accessory storage case.




ACR 01-0057 Weatherproof Logger Box ACR 01-0057
NEMA 4X clear-faced weatherproof box for all ACR loggers, Size: 18 x 13 x 10cm (7 x 5 x 4").




ACR 01-0165 Net Fast Sample Power Supply - 120V N A ACR 01-0165
120V AC to 5V DC power supply for SmartReader Plus networks with a minimum of three loggers or >50ft of network cable. Includes inYin splitter (YA-200).




Ask a question about ACR 01-0012 SmartReader Plus 5 Data Logger

Customer Reviews for the ACR ACR 01-0012

ACR ACR 01-0012 Offers

Features

  • Three channels
  • Monitor extremely high temperatures
  • Monitor temperature over a wide range
  • Use with a variety of different thermocouple probes
  • Greater resolution and accuracy than SR5

Applications

  • Monitor performance of gas-fired heating equipment
  • Verifying concrete curing temperatures
  • Process verification

ACR ACR 01-0012 Specifications

Temperature Sensor (Internal)
Type NTC Thermistor - 10,000 Ω at 77˚F (25˚C)
Range -40 to 158˚F (-40 to 70°C)
Accuracy +/-0.3ºF over the range of 32 to 158ºF (+/-0.2ºC over the range of 0 to 70ºC)
Resolution 0.05ºF (0.03ºC) at 25ºC; better than 0.12ºF (0.07ºC) between -13 and 158ºF (-25 and 70˚C)
Better than 0.23˚F (0.13ºC) between -40 and -13ºF (-40 and -25˚C)
General Specifications
Software Requirements TrendReader® Standard 2 (compatible with Windows® 2000, and XP)
PC Requirements IBM PC or 100% compatible with at least one free serial port, 2 MB of RAM memory, and 2 MB of hard disk space
Operating Limits -40 to 158°F (-40 to 70°C) and 0 to 95% RH (non-condensing)
Sampling Methods Continuous (First-in, First-out), Stop When Full (Fill-then-stop)
Clock Accuracy +/-2 seconds per day
Mounting Magnetic backing or locking eyelet
Resolution 12-bit (1 part in 4096)
Battery 3.6 V Lithium
Case Material Noryl® plastic
Dimensions 4.2 x 2.9 x 0.9" (107 x x 74 x 22 mm)
Weight 3.75 oz (110 g)
Click here for complete specifications on the ACR ACR 01-0012

What's included with the ACR ACR 01-0012

  • ACR 01-0012 SmartReader Plus 5 Data Logger

Click on a category to view a selection of compatible accessories with the ACR 01-0012 SmartReader Plus 5 Data Logger.

ACR Fast Sampling Battery Pack BP-101 ACR 01-0078
Portable power supply for SmartReader Plus data loggers to allow them to sample faster than 8 seconds.




ACR 31-0016 Type-T Thermocouple Wire, bulk wire ACR 31-0016
The 20 gauge Type-J thermocouple wire features a duplex Teflon insulation jacket. It also features a measurement range of -325 to 750°F (-200 to 400°C). The wire comes sold by the foot.




ACR 31-0015 Type-K Thermocouple Wire, bulk wire ACR 31-0015
The 20 gauge Type-J thermocouple wire features a duplex Teflon insulation jacket. It also features a measurement range of -145 to 2100°F (-100 to 1150°C). The wire comes sold by the foot.




ACR 31-0014 Type-J Thermocouple Wire, bulk wire ACR 31-0014
The 20 gauge Type-J thermocouple wire features a duplex Teflon insulation jacket. It also features a measurement range of -55 to 1100°F (-50 to 600°C). The wire comes sold by the foot.




ACR 01-0104 Type-T Thermocouple Wire, welded tip ACR 01-0104
The 20 gauge Type-J thermocouple wire features a welded tip and a duplex insulated PVC jacket. It also features a measurement range of -325 to 750°F (-200 to 400°C) and is 12" in length.




ACR 01-0102 Type-J Thermocouple Wire , welded tip ACR 01-0102
The 20 gauge Type-J thermocouple wire features a welded tip and a duplex insulated Teflon jacket. It also features a measurement range of -55 to 1100°F (-50 to 600°C) and is 12" in length.




ACR 01-0088 Logger-PC Interface Cable, 4' ACR 01-0088
Connect the SmartReader Plus data logger to PC computer through a USB port with this interface cable which measures 4' (1.22 m). In addition, this interface cable has a 0.138" (3.5 mm) stereo jack connection.




ACR 01-0077 Logger-PC Interface Cable (IC-101) ACR 01-0077
9-pin PC serial port to logger interface cable. Compatible with SmartReader and SmartReader Plus loggers.




ACR 01-0103 Type-K Thermocouple Wire, welded tip ACR 01-0103
The 20 gauge Type-K thermocouple wire features a welded tip and a duplex insulated Teflon jacket. It also features a measurement range of -145 to 2100°F (-100 to 1150°C) and is 12" in length.




ACR 29-0004 Terminal Block - 11 Pin ACR 29-0004
11-pin female teminal block for SmartReader/SmartReader Plus sensor inputs.




ACR 01-0171 SmartReader Plus Display Module ACR 01-0171
Portable Real-time Display Module for any SmartReader Plus Data Logger (2 AA batteries and 1 foot cable included).




ACR 01-0168 Alarm Module - 100 - EU ACR 01-0168
Alarm module, stereo Y-adapter, 1ft male-male stereo cable, and 240V Cont. Europe power supply for SmartReader Plus loggers.




ACR 01-0167 Alarm Module - 100 - NA ACR 01-0167
Alarm module, stereo Y-adapter, 1ft male-male stereo cable, and 120V NA power supply for SmartReader Plus loggers.




ACR 01-0098 Network Y Splitter - Stereo (YA-200) ACR 01-0098
Allows a SmartReader Plus logger to be added to an ACR-stereo type network. 1 male and 2 female ends. Includes 1ft male to male adapter cable.




ACR Systems SC-100 General Purpose Logger Storage Case ACR 01-0106
General Purpose Logger Storage Case, Briefcase style, locking, customizable logger and accessory storage case.




ACR 01-0057 Weatherproof Logger Box ACR 01-0057
NEMA 4X clear-faced weatherproof box for all ACR loggers, Size: 18 x 13 x 10cm (7 x 5 x 4").




ACR 01-0165 Net Fast Sample Power Supply - 120V N A ACR 01-0165
120V AC to 5V DC power supply for SmartReader Plus networks with a minimum of three loggers or >50ft of network cable. Includes inYin splitter (YA-200).




Ask a question about ACR 01-0012 SmartReader Plus 5 Data Logger

Customer Reviews for the ACR ACR 01-0012

More ACR Products