Dent CT-SRS-005-U Small Revenue Grade Split Core Current Transformers, 5A

Model: CT-SRS-005-U

Dent CT-SRS-005-U Small Revenue Grade Split Core Current Transformers, 5A

Model: CT-SRS-005-U

Hinged split-core current transformers are designed for Revenue Grade applications that require maximum accuracy and precision.

Hinged split-core current transformers are designed for Revenue Grade applications that require maximum accuracy and precision.

Sale Price $155.93 CAD
Regular Price $165.00 CAD
Availability 2 in Stock
Quantity

DENT Instruments CT-SRS-005-U Offers

The superior performance, robust design, and unique shrouded snap, lock & tilt top of the SRS Series CTs make them ideal for field installation in high accuracy current measurement applications such as energy and demand metering, tenant submetering and load surveys.

Standard Features:

  • 5A Revenue Grade Split Core
  • 0.2% of rated current
  • Phase Shift <0.2 degrees
  • UL2808 and CSA C22.2

CT-SHS-0005-U Specifications

Key Specifications
Window Size1.0 cm (0.4")
Current Range0.05—10A
Output333 mV @ rated current
Accuracy+/‐ 0.5% at 0.5% to 140% of rated current
Electrical
Output333 mV
Phase Shift+/‐ 0.5° at rated current
Frequency Range10 Hz to 10 KHz
Mechanical
Dimensions6.4 x 2.5 x 5.1 cm (2.5 x 1.0 x 2.0")
PolarityWhite lead is positive
Output Lead2.7 M (8'), twisted pair, 22 AWG
Operating Temperature–20° to 50°C (-4° to 122°F)
Other Features
Window Size1.0 cm (0.4")
Weight136 g (4.8 oz)
Dielectric Strength5000V around the case, 600V rated leads
Storage TemperatureMaximum 105°C (220°F)
Case ProtectionPlastic ABS/PVS or Epoxy encapsulated housing
Safety
Working Voltage600 Vrms maximum
UL listedCAN/CSA‐C60044‐1‐2007 pts 1 & 2
CE MarkANSI/IEEE C57.13, IEEE C57.13.2
Click here for complete specifications on the Dent CT-SRS-005-U

What's included with the Dent CT-SRS-005-U

  • Dent CT-SRS-005-U Small Revenue Grade Split Core Current Transformers, 5A

Extending the Leads on Your DENT Current Transformer

One of the most frequently asked questions in our tech support department is this: "Can I get CTs with longer leads or extend the leads myself? What's the maximum length for CT leads?".

Standard lead length for a DENT current transformer is 3 meters (with a 7 meter option available for some models). Occasionally, because of electrical room layout or other factors, there is a requirement for longer leads on a current transformer. Therefore, extending the CT leads is necessary. The following is a brief overview of options for extending CT leads based on CT type. Note that the length recommendations listed below apply to PowerScout Series and ELITEpro XC instruments ONLY. To extend RoCoil leads for use with the TCA-5, please contact our experts to get advice specific to your application.

Split-Core/Hinged Split-Core Current Transformers (Including Revenue Grade Hinged Split Cores)

DENT Split-Core/Hinged Split-Core Current Transformers - ITM Instruments
MAXIMUM LENGTH

Split-Core Current Transformers leads can be extended up to 500 feet using extensions of the same wire type/AWG.

WIRE TYPE

600 V Rated VW-1, 105°C, 20 AWG, black and white twisted pair, cURus

RECOMMENDED SPLICING METHOD/MATERIALS

Sure-Connect sealed butt splices which require a crimping tool and hot air gun. Always follow manufacturer's instructions.


RoCoil Current Transformers

DENT RoCoil Current Transformers - ITM Instruments
MAXIMUM LENGTH

RoCoil CT leads can be extended up to 100 feet using extensions of the same wire type/AWG.

WIRE TYPE

"Bare" RoCoil: Shielded cable with thermoplastic insulation, 1000 V AC VW-1, 2 x 26 AWG, 80°C, cURus

RECOMMENDED SPLICING METHOD/MATERIALS ("BARE ROCOIL ONLY)

Sure-Connect sealed butt splices which require a crimping tool and hot air gun. Always follow manufacturer's instructions.


Solid Core (Toroid) Current Transformers

DENT Solid Core (Toroid) Current Transformers - ITM Instruments
MAXIMUM LENGTH

Solid Core (Toroid) CT leads can be extended up to 500 feet using extensions of the same wire type/AWG.

WIRE TYPE

UL1015 24 AWG 7 Strand Black & White Twisted Pair (1 twist per inch), 600 V rated

RECOMMENDED SPLICING METHOD/MATERIALS

Sure-Connect sealed butt splices which require a crimping tool and hot air gun. Always follow manufacturer's instructions.

Optimizing Performance from Rogowski Coil Current Transformers

DENT Rogoski Coil - ITM Instruments
WHAT IS A ROGOWSKI COIL?

Rogowski coil, named after Walter Rogowski, is an electrical device for measuring alternating current (AC) or high-speed current pulses. It consists of a helical coil of wire with the lead from one end returning through the center of the coil to the other end so that both terminals are at the same end of the coil. The whole assembly is then wrapped around the straight conductor whose current is to be measured.

Since the voltage that is induced in the coil is proportional to the rate of change of current in the straight conductor the output of the Rogowski coil is usually connected to an electrical (or electronic) integrator circuit in order to provide an output signal that is proportional to the current.

The relationship between voltage and rate of change of current is explained in the following equation where "V" is voltage and "M" is a constant:

DENT Rogoski Coil - ITM Instruments
WHY CHOOSE A ROGOWSKI COIL CURRENT TRANSFORMER?
Flexible Rogowski Coils, such as the DENT RoCoil, are designed for easy placement around cable bundles, large buss bars, or within tight breaker panels. Their design has several advantages over traditional split core current transformers including:

  1. Open-ended, flexible design allows it to be wrapped around a live conductor without disturbing it.
  2. Rogowski coils feature an air core rather than an iron core, which results in low inductance and faster response time to changing currents.
  3. Highly linear, even when subjected to large currents such as those used in electric power transmission, welding, or pulsed power applications.
  4. Largely immune to electromagnetic interference.
HOW TO MAXIMIZE PERFORMANCE FROM A ROGOWSKI COIL CURRENT TRANSFORMER

Rogowski coil accuracy is usually calibrated with the conductor centered in the CT window. In practice, however, the CT typically hangs on the conductor which can introduce measurement errors. Note that the error is greatest when the CT connector hangs on the conductor. The following diagram outlines the error introduced simply by moving the conductor to different positions within the opening of the Rogowski coil.

DENT Rogoski Coil - ITM Instruments

Best practice for Rogowski coil installation is to center the conductor as best as conditions allow. In addition, it's a good idea to keep any other conductors (those you do not wish to measure) at a minimum distance of 2x the diameter of the Rogowski coil CT.

Also, keep in mind that although a Rogowski coil is ideal for large amperage loads, accuracy of the coil may be reduced on smaller loads (<20 A).

Ask a question about Dent CT-SRS-005-U Small Revenue Grade Split Core Current Transformers, 5A

Customer Reviews for the Dent CT-SRS-005-U

DENT Instruments CT-SRS-005-U Offers

The superior performance, robust design, and unique shrouded snap, lock & tilt top of the SRS Series CTs make them ideal for field installation in high accuracy current measurement applications such as energy and demand metering, tenant submetering and load surveys.

Standard Features:

  • 5A Revenue Grade Split Core
  • 0.2% of rated current
  • Phase Shift <0.2 degrees
  • UL2808 and CSA C22.2

CT-SHS-0005-U Specifications

Key Specifications
Window Size1.0 cm (0.4")
Current Range0.05—10A
Output333 mV @ rated current
Accuracy+/‐ 0.5% at 0.5% to 140% of rated current
Electrical
Output333 mV
Phase Shift+/‐ 0.5° at rated current
Frequency Range10 Hz to 10 KHz
Mechanical
Dimensions6.4 x 2.5 x 5.1 cm (2.5 x 1.0 x 2.0")
PolarityWhite lead is positive
Output Lead2.7 M (8'), twisted pair, 22 AWG
Operating Temperature–20° to 50°C (-4° to 122°F)
Other Features
Window Size1.0 cm (0.4")
Weight136 g (4.8 oz)
Dielectric Strength5000V around the case, 600V rated leads
Storage TemperatureMaximum 105°C (220°F)
Case ProtectionPlastic ABS/PVS or Epoxy encapsulated housing
Safety
Working Voltage600 Vrms maximum
UL listedCAN/CSA‐C60044‐1‐2007 pts 1 & 2
CE MarkANSI/IEEE C57.13, IEEE C57.13.2
Click here for complete specifications on the Dent CT-SRS-005-U

What's included with the Dent CT-SRS-005-U

  • Dent CT-SRS-005-U Small Revenue Grade Split Core Current Transformers, 5A

Extending the Leads on Your DENT Current Transformer

One of the most frequently asked questions in our tech support department is this: "Can I get CTs with longer leads or extend the leads myself? What's the maximum length for CT leads?".

Standard lead length for a DENT current transformer is 3 meters (with a 7 meter option available for some models). Occasionally, because of electrical room layout or other factors, there is a requirement for longer leads on a current transformer. Therefore, extending the CT leads is necessary. The following is a brief overview of options for extending CT leads based on CT type. Note that the length recommendations listed below apply to PowerScout Series and ELITEpro XC instruments ONLY. To extend RoCoil leads for use with the TCA-5, please contact our experts to get advice specific to your application.

Split-Core/Hinged Split-Core Current Transformers (Including Revenue Grade Hinged Split Cores)

DENT Split-Core/Hinged Split-Core Current Transformers - ITM Instruments
MAXIMUM LENGTH

Split-Core Current Transformers leads can be extended up to 500 feet using extensions of the same wire type/AWG.

WIRE TYPE

600 V Rated VW-1, 105°C, 20 AWG, black and white twisted pair, cURus

RECOMMENDED SPLICING METHOD/MATERIALS

Sure-Connect sealed butt splices which require a crimping tool and hot air gun. Always follow manufacturer's instructions.


RoCoil Current Transformers

DENT RoCoil Current Transformers - ITM Instruments
MAXIMUM LENGTH

RoCoil CT leads can be extended up to 100 feet using extensions of the same wire type/AWG.

WIRE TYPE

"Bare" RoCoil: Shielded cable with thermoplastic insulation, 1000 V AC VW-1, 2 x 26 AWG, 80°C, cURus

RECOMMENDED SPLICING METHOD/MATERIALS ("BARE ROCOIL ONLY)

Sure-Connect sealed butt splices which require a crimping tool and hot air gun. Always follow manufacturer's instructions.


Solid Core (Toroid) Current Transformers

DENT Solid Core (Toroid) Current Transformers - ITM Instruments
MAXIMUM LENGTH

Solid Core (Toroid) CT leads can be extended up to 500 feet using extensions of the same wire type/AWG.

WIRE TYPE

UL1015 24 AWG 7 Strand Black & White Twisted Pair (1 twist per inch), 600 V rated

RECOMMENDED SPLICING METHOD/MATERIALS

Sure-Connect sealed butt splices which require a crimping tool and hot air gun. Always follow manufacturer's instructions.

Optimizing Performance from Rogowski Coil Current Transformers

DENT Rogoski Coil - ITM Instruments
WHAT IS A ROGOWSKI COIL?

Rogowski coil, named after Walter Rogowski, is an electrical device for measuring alternating current (AC) or high-speed current pulses. It consists of a helical coil of wire with the lead from one end returning through the center of the coil to the other end so that both terminals are at the same end of the coil. The whole assembly is then wrapped around the straight conductor whose current is to be measured.

Since the voltage that is induced in the coil is proportional to the rate of change of current in the straight conductor the output of the Rogowski coil is usually connected to an electrical (or electronic) integrator circuit in order to provide an output signal that is proportional to the current.

The relationship between voltage and rate of change of current is explained in the following equation where "V" is voltage and "M" is a constant:

DENT Rogoski Coil - ITM Instruments
WHY CHOOSE A ROGOWSKI COIL CURRENT TRANSFORMER?
Flexible Rogowski Coils, such as the DENT RoCoil, are designed for easy placement around cable bundles, large buss bars, or within tight breaker panels. Their design has several advantages over traditional split core current transformers including:

  1. Open-ended, flexible design allows it to be wrapped around a live conductor without disturbing it.
  2. Rogowski coils feature an air core rather than an iron core, which results in low inductance and faster response time to changing currents.
  3. Highly linear, even when subjected to large currents such as those used in electric power transmission, welding, or pulsed power applications.
  4. Largely immune to electromagnetic interference.
HOW TO MAXIMIZE PERFORMANCE FROM A ROGOWSKI COIL CURRENT TRANSFORMER

Rogowski coil accuracy is usually calibrated with the conductor centered in the CT window. In practice, however, the CT typically hangs on the conductor which can introduce measurement errors. Note that the error is greatest when the CT connector hangs on the conductor. The following diagram outlines the error introduced simply by moving the conductor to different positions within the opening of the Rogowski coil.

DENT Rogoski Coil - ITM Instruments

Best practice for Rogowski coil installation is to center the conductor as best as conditions allow. In addition, it's a good idea to keep any other conductors (those you do not wish to measure) at a minimum distance of 2x the diameter of the Rogowski coil CT.

Also, keep in mind that although a Rogowski coil is ideal for large amperage loads, accuracy of the coil may be reduced on smaller loads (<20 A).

Ask a question about Dent CT-SRS-005-U Small Revenue Grade Split Core Current Transformers, 5A